1LE1, 1LA6,1LA7, 1LG
SIEMENS EUROPE
SIMOTICS GP
SIEMENS STANDARD MOTOR
CAST IRON
ALUMINIUM
0.75KW TO 315KW
2 POLE, 4 POLE, 6 POLE, 8 POLE
B3, B5, B14, B35, V1
IP55 ( STANDARD ), IP56 /IP65 ( OPTIONAL )
IE1
IE2
IE3
SIEMENS standard motors
Standard motors from Siemens are characterized by their flexibility, ruggedness and energy efficiency. In general, all motors are suitable for converter-fed operation with line voltages of up to 460 V +10 %. The motors are designed to fulfill the requirements of the European and international markets with an output range from 0.09 to 315 kW.
IEC motors for the European and international market
The standard motors comply both electrically and mechanically with the applicable IEC/EN standards. For exporting to China, CCC certified motors (China Compulsory Certification) can be supplied.
IEC motors specially for the North American market
Motors are also available to the NEMA specification (National Electrical Manufacturers Association), with UL approval (Underwriters Laboratories Inc.) and CSA certification (Canadian Standard Association) for exporting to NAFTA states (USA, Canada and Mexico). The mechanical design of all motors is compliant only to IEC/EN, not to NEMA dimensions.
NEMA motors for the North American market
For further information about NEMA motors according to NEMAstandard MG1: http://www.sea.siemens.com/motors
Depending on requirements, energy-saving motors for a positive energy balance are available that are compliant with the legal requirements applicable in the European economic area in accordance with EU Directive 640/2009 as well as for the North American market in accordance with US federal law EISA (Energy Independence Security Act).
The EU Directive defines the minimum efficiency for 2, 4 and 6-pole motors in the output range from 0.75 to 375 kW. The efficiency levels are grouped into 3 efficiency classes (IE = International Efficiency):
IE1, IE2 and IE3 efficiencies, 4-pole 50 Hz
Further information at: http://www.siemens.com/international-efficiency
The Energy Policy Act (EPAct) was superseded in December 2010 by the Energy Independence Security Act (EISA).
Since then, EISA has extended the legal minimum efficiency requirements.
The following motors must satisfy the NEMA Premium Efficient Level (NEMA MG Table 12-12):
Exception/expansion – The following motors must comply with the NEMA Energy Efficient Level (NEMA MG Table 12-11):
For details, see NEMA MG1, Table 12-11 and Table 12-12.
The EISA act lays down that the nominal efficiency at full load and a "CC" number (Compliance Certification) must be included on the rating plate. The "CC" number is issued by the US Department of Energy (DOE). The following information is stamped on the rating plate of EISA motors which must be marked by law:
The product range of energy-saving motors exclusively comprises motors in the EU efficiency classes IE1 "Standard Efficiency", IE2 "High Efficiency", and IE3 "Premium Efficiency". The procedure for determining the efficiency is based on IEC 60034-2-1:2007. With these energy-saving motors, a significant reduction in energy costs can be achieved.
IEC motors from Siemens for the North American market are CC certified and stamped with the number CC032A on the rating plate. Motors are offered with the CSA Energy Efficiency Verification Mark specially for the Canadian market.
IE3 double rating plate
For further examples, see “Examples of rating plates”.
Standard motors with increased output and compact construction can be used to advantage in confined spaces. For a slightly longer overall length, the output is at least as high as that of the next largest shaft height. These compact motors are also optimized for efficiency and therefore reduce the operating costs.
Naturally cooled motors with surface cooling without external fan are suitable for the following operating conditions:
The most popular basic versions of motor series 1LA9 and 1LG6, and the corresponding successor types 1LE1001 and 1LE1501 are available under special terms as so-called "Preferred motors". Most of the "Preferred motors" are also available with a shorter delivery time as so-called "Express motors".
The standard delivery time for Express motors is 1 to 2 days from the time of clarification of the order at the factory until dispatch from the factory. To determine the delivery date at the customer site, the appropriate shipping time must be added.
For further information and the complete range, see "Preferred and Express motors".
Motor version |
Motor type (alum.) |
Motor type – Frame size – Rated output at 50 Hz (values in kW) or 60 Hz (values in hp) |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
63 |
71 |
80 |
90 |
100 |
112 |
132 |
160 |
180 |
200 |
225 |
||
IE2 High Efficiency |
1LA9 |
1LA9 – 0.12 … 37 kW |
– |
|||||||||
IE1 Standard Efficiency |
1LA7/1LA5 |
1LA7 – 0.09 … 18.5 kW |
1LA5 – 11 … 45 kW |
|||||||||
1LA9 |
1LA9 with increased output – 0.21 … 53 kW |
– |
||||||||||
1PP7/1PP5 |
1PP7 – 0.09 … 18.5 kW |
1PP5 – 11 … 37 kW |
– |
|||||||||
1LP7/1LP5 |
1LP7 – 0.045 … 7 kW |
1LP5 – 5.5 … 16.5 kW |
– |
|||||||||
NEMA Energy Efficient |
1LA9 |
1LA9 – 0.12 … 37 kW / 0.16 … 50 hp |
– |
|||||||||
Pole-changin |
1LA7/1LA5 |
1LA7 – 0.1 … 17 kW |
1LA5 – 3 … 31 kW |
– |
||||||||
For converter-fed operation only |
1LA7/1LA5 |
– |
– |
– |
– |
1LA7 – 1.5 … 11 kW |
1LA5 – 15 … 45 kW |
Standard motors from Siemens offer the user numerous advantages:
1) Canadian Standard Association
2) Underwriters Laboratories Inc.
3) EXAM BBG Prüf und Zertifier GmbH (previously BVS = Bergbau Versuchsstrecke)
4) Physikalisch-Technische Bundesanstalt
5) China Quality Certification
The numerous available options enable standard motors from Siemens to be used in every area of industry and every sector. They are suitable both for special environmental conditions such as those that predominate in the chemical or petrochemical industry as well as for most climatic requirements such as those of offshore applications. Their large range of line voltages enables them to be used all over the world.
The wide field of implementation includes the following applications:
This table lists the most important technical data. For more information and details, see Catalog D 81.1 · 2008 Part 0 "Introduction".
Type of motor |
SIMOTICS GP/SD 1LA/1LG/1LP/1PP IEC Low-Voltage Motors |
Connection types |
Star connection/delta connection You can establish the connection type to be used from the Order No. supplements for the required motor |
Number of poles |
2, 4, 6, 8, pole-changing for constant and square-law load torque |
Rated speed |
750 ... 3000 rpm |
Rated output |
0.09 ... 315 kW |
Rated torque |
0.25 ... 1700 Nm |
Insulation of the stator winding according to |
Temperature class 155 (F), used according to temperature class 130 (B) DURIGNIT IR 2000 insulation system |
Degree of protection |
IP55 as standard |
Cooling |
|
Admissible coolant temperature and site altitude |
–20 ... +40 °C as standard, site altitude up to 1000 m above sea level |
Standard voltages |
50 Hz: 230 V, 400 V, 500 V, 690 V |
Type of construction |
|
Paint finish |
Standard: Color RAL 7030 stone gray
Climate group "worldwide" with special finish See "Paint finish" in Catalog D 81.1 · 2008 Part 0 "Introduction". |
Vibration severity level |
Level A (normal, without special vibration requirements) |
Shaft extension |
Balance type: Half-key balancing |
Sound pressure level |
The corresponding sound pressure level is listed in the selection and ordering data for the required motor. |
Weights |
The corresponding weight is listed in the selection and ordering data for the required motor. |
Mechanical limit speeds |
The corresponding limit speed for the required motor is listed in the table, see “Mechanical limit speeds nmax at maximum supply frequency fmax“. |
Packaging weights and dimensions |
See "Packaging weights and packaging dimensions" in Catalog D 81.1 · 2008 Part 0 "Introduction". |
Rating plates |
Fixed to the motor |
Connection and connection box |
See "Connection, circuit and connection boxes" in Catalog D 81.1 · 2008 Part 0 "Introduction". |
Bearing designs |
See "Bearings" in Catalog D 81.1 · 2008 Part 0 "Introduction". |
Cantilever forces |
See "Admissible cantilever forces" in Catalog D 81.1 · 2008 Part 0 "Introduction". |
Options |
See "Supplements to order numbers and special versions". |
All the data listed in the catalog is applicable for a 50 Hz line supply. With converter-fed operation, the reduction factors for constant torque and drives for fans, pumps and compressors must be observed. Noise values for motors operating with a converter at frequencies other than 50 Hz are available on request.
When the motor is operated at its rated frequency, it is important to note that the maximum speeds are limited by the limits for the roller bearings, critical rotor speed and rigidity of the rotating parts.
The fan noise can increase at speeds that are higher than the rated speed of self-ventilated motors. To increase motor utilization at low speeds it is recommended that forced-ventilated motors are used.
High speeds that exceed the rated speed and the resulting increased vibrations alter the mechanical running smoothness and the bearings are subjected to increased mechanical stress. This reduces the grease lifetime and the bearing lifetime. More detailed information on request.
SIMOTICS Low-Voltage Motors
Type Series 1LE, 1PC, 1LA, 1LG, 1LL, 1LP, 1MA, 1MJ, 1PP, 1PQ
Frame sizes 63 to 450
Power range 0.09 to 1250KW
( refer catalog D 81.1 January 2012 )