Product Overview
 AP-YV3302H electrostatic sensor is a detecting instrument developed and produced by Anping Company to detect the static voltage on the surface of an object with static electricity, which adopts the non-contact measurement technology to minimize the impact of the detecting instrument on the electrostatic field on the surface of the object and ensure the accuracy of measurement. II. Scope of Application
It can be widely applied in the industries such as electronics, photoelectricity and plastics. 

Product Features
  III. Product Features1. With comfortable feel and beautiful appearance.
2. Detection distance can be selected via dial switch.
3. Wide detection potential range and high detection precision.
4. Alarm threshold can be set and red light alarm indicatesexceeding threshold.
5. High-definition and all-dimensional LCD data display terminal.
6. Monitoring data can be transmitted to PC in real time.
7. Conformable for operation and convenient for use.



IV. Product Parameters and Technical Functions
1. Performance parameters
1). Technical specifications:

 
No. Technical specifications
1 Working voltage DC8-24V
2 Working current <20mA
3 Vibration 1KHz
4 Noise 5dB
5 Signal output RS485
NPN (Collector control, 24/100mA)
6 Communication distance 500m
7 Alarm indication Red light LED
8 Threshold setting ±100V (default)
9 Alarm range ±50→±5000V
10 Detection angle 15°
11 Startup stand-by time 5s
12 Infrared control distance 1m
  
※ Due to the improvement and upgrading of the product, the specification and performance of the product may be changed; Subject to the real product and please understand that notice cannot be given in advance. 
Prompts of operating technologies
 2.1. During operation, align with the front LED of the product (the distance is not more than 1m), press the unlock key at first, then press the corresponding functional keys to set, and the red light flashes when the key is pressed.2.2. During zeroing setting, the calibration plate should be much larger than the detection window of sensor, and the polar plate and sensor should be well grounded.  
2.3. During the calibration operation, the calibration plate should be much larger than the detection window of sensor and the sensor should be well grounded.
2.4. There should be no shield between the sensor and the detected object; otherwise the accuracy of the detection result will be affected.
2.5. There should be no electrical equipment that may affect the sensor within the detection range of the sensor.
2.6. To accurately measure the charged object, the plane of the sensor detection window must be parallel to the surface of the detected object.
2.7. When the charged object is smaller than the calibration plate, the measured value will be smaller than the actual electrostatic value of the charged object.
2.8. When the charged object is larger than the calibration plate, the measured value will be larger than the actual electrostatic value of the charged object.
2.9. Do not set zero in electrostatic charge state or in the electrostatic measurement process (non-static calibration process); if zero clearing is made during the electrostatic test, the displayed electrostatic value will be zero.
2.10. Influence of temperature and humidity on electrostatic detection:
The lower the temperature is, the smaller the humidity is, the less water is contained in the space, and the more easily the surrounding object triboelectric and the greater the interference to the electrostatic detection is.
1) The higher the temperature is, the higher the humidity is, the more water is contained in the space, and the more active the movement of water molecules is, which is easy to produce corona or spark discharge to the calibration device and the greater the influence on the uniform electric field generated by the calibration device, the weaker the uniform electric field will be.
2) Under the same humidity, the lower the temperature is, the less water is contained in the space, and the more easily the surrounding object triboelectric and the greater the influence on the electrostatic detection is.
Therefore, during electrostatic calibration/detection, the environmental temperature and humidity should be clearly indicated during calibration/detection.
2.11. Due to the existence of the cosmic rays and micro-radioactive substance in the environment as well as the use of various kinds of electrical equipment, there are inevitably more or less positive and negative irons in the detection space, which may also have certain impact on the detection results.

 

3.Display information of monitoring terminalWorking status: whether the sensor works normally and has alarm output.
Equipment address: display the address set by the sensor.
Detection distance: display the detection distance set by the sensor.
Threshold voltage: display the set safety (alarm) threshold of static voltage.
Real time voltage: display the static voltage value on the surface of the measured object. 

Mechanical parameters
 4. Mechanical parameters①Mechanical parameters of sensor:
Overall dimension: <44*33*85mm (L*W*H)
Net weight: about 49.7g
The overall dimension of sensor is shown as follows: 

②Mechanical parameters of monitoring terminal
Overall dimension: 100*120*25mm (L*W*H)
Net weight of monitoring terminal: about 400g
The overall dimension of monitoring terminal is shown as follows:

③Mechanical parameters of power adapter:
Overall dimension: 124*61*40mm (L*W*H)

Net weight of power adapter: about 234g

The overall dimension of power adapter is shown as follows:

 ④Mechanical parameters of communication converter:
Overall dimension: <90*28*22mm (L*W*H)
Net weight of communication converter: about 20.5g
 The overall dimension of communication converter is shown as follows: 

⑤Mechanical parameters of system integrated power supply:

Overall dimension: 380*160*50mm (L*W*H)
Net weight of terminal power supply: about 2500g
The overall dimension of terminal power supply is shown as follows: 