Specifications
  • TruLine Nitrate Electrode Kit Includes ISE with replaceable sensor module and refillable reference, fill solution, ISA, and high (1000 mg/L) standard.: Benchtop Yes Buffer Recognition Yes Connector BNC Equipment used with TruLab 1320, MultiLab 4010-2 or 4010-3 with BNC adapter (108132Y) GLP Compliance Yes Operating Temperature 23掳F to 212掳F, -5掳 to 100掳C Parameters Measured Nitrate Sampling Yes User Calibratable Yes User Replaceable Yes Warranty 1 year
Penerangan

The TruLine Nitrate ISE features BNC connection and can be used with the YSI TruLab 1320. It can also be used with the YSI MultiLab 4010-2 or 4010-3 if a BNC adapter is installed.

The TruLine Nitrate laboratory electrode kit includes a PVC membrane combination ISE with replaceable sensor module and refillable reference, bottle of fill solution (30 mL), bottle of ISA (30 mL), and small bottle (30 mL) of high (1000 mg/L) standard.

Nitrate ISE range: 0.4 to 62000 mg/L

EPA approved for wastewater and drinking water compliance reporting of nitrate.

 

There are 15 electrodes in the TruLine ISE series, with each electrode measuring the effective ion concentration of a different ionic species. This provides our customer with a wide range of ISEs to choose from. 

ISE parameters include: AmmoniaAmmoniumBromideCadmiumCalciumChlorideCopperCyanideFluorideIodideLead, Nitrate, PotassiumSilver/Sulfide, and Sodium. Some ISEs are EPA approved for wastewater and/or drinking water compliance reporting.

Each TruLine ISE features an integrated reference.  This eliminates the need for a separate reference half-cell when measuring ion concentration and is more convenient.  Each ISE can be refilled with reference/electrode filling solution, extending the life of each ISE.  The electrodes also feature a double-junction reference for optimum performance in the lab.

ISE TruLine Electrode features include:

*The ammonia ISE is not a true double-junction electrode, but it does contain a single-junction pH electrode inside an outer membrane that only ammonia can permeate.

**Cyanide and sulfide standards not included with respective kits.