TPI-750a / 753a Refrigerant Leak Detector

TPI-750a / 753a Refrigerant Leak Detector

Kategori: TPI (Test Products International, USA) Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di culmi.com.my

Penerangan

TPI-750a / 753a Refrigerant Leak Detector

Model

TPI-750a (0.2 oz/year) Refrigerant Leak Detector = RM650.00 Per Unit (5-10-2024=AAA30.983) (30-6-2022=AA29.74)
TPI-753a (0.1 oz/year) Refrigerant Leak Detector = RM1,069.00 Per Unit (5-10-2024=AAA40.042) (30-9-2022=AA40)

Accessories

A712 SENSOR FOR TPI 750A
A721 SENSOR FOR TPI 753A


• Detects all existing refrigerants and blends including 404A, PURON 410A and *R-507 (AZ50). 
• 400 hour individual sensor life; a spare sensor is included with each instrument for a total of 800 hours of continuous sensor use. 
• Fast response; Begin testing immediately after power on

Features


• Pinpoint small leaks easily by elimination of background concentration with fully adjustable tic rate 
• Visual indicators for power, tic rate and battery replacement 
• One-hand operation 
• Optional earphone attachment 

Model 750A Specifications
 Sensitivity  0.2 oz /yr (R22 / R134a)
 Pump Driven  No
 Scan Mode with High/Low Sensitivity  Yes
 Sensor Type  Corona Discharge
 Spare Sensor Included  Yes
 Built-in Alarm  No
 Operation  Thumb Wheel
 Goose Neck Length  16”
 Adjustable Tic Rate  Yes
 Leak Indication  Audible and Visual
 Alarm  Audible
 Battery  1.5V “C” (2)
 Carrying Case  Soft Pouch

Model 753A Specifications
 Sensitivity  0.1 oz /yr (R22 / R134a)
 Pump Driven  Yes
 Scan Mode with High/Low Sensitivity  Yes
 Sensor Type  AIT Micro Tip
 Spare Sensor Included  Yes
 Built-in Alarm  No
 Operation  Push Button
 Goose Neck Length  16”
 Adjustable Tic Rate  Yes
 Leak Indication  Audible and Visual
 Battery  1.5V “C” (2)
 Carrying Case  Soft Pouch

TPI-753a Incorporated With Pump

Generally, refrigerant leak detectors with pumps respond and clear faster as you enter or leave the leak area. This is most important when locating small leaks.

TPI-753a Can Detect SF6

Sulfer hexafluoride (SF6) is used in high voltage insulation as found in high voltage lines and circuit breakers. SF6 is toxic and emitted into the air when high voltage insulation begins to degrade. The 753a will detect SF6 at a level of 750 ppm or higher.

Technical Tips:

Even though the sensors are very durable, you can extend the sensor life of your leak detector. Simply fit a ½” long piece of vinyl tubing onto the sensor tip. This will help prevent foreign material from getting into the sensor during tests. Clean or replace the tube regularly.

Is there a way to determine how many parts per million (ppm) a leak of 0.1 ounce per year(oz/yr) is?

A leak of 134a refrigerant measuring 0.1 oz/yr is equivalent to approximately 380 to 400 ppm. A leak measuring 0.2oz/yr is equivalent to approximately 760 to 800 ppm.


 
 

Lebih maklumat tentang Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd
Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd Air Conditioning & Refrigeration Parts Supplier Subang Jaya, Selangor, Brazing Equipment & Accessories Supplies Kuala Lumpur (KL), Malaysia ~ Culmi Air-Cond & Refrigeration Parts Supply Sdn Bhd