Item |
Specifications |
Part Number |
ER-VW |
Products Name |
Thin-type Ionizer |
Product details |
Spot type |
The price of the product |
Please contact our office |
Charge removal time |
1 sec. or less (plus or minus1,000 V to plus or minus100 V)
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) |
Ion balance |
plus or minus10 V or less
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.) |
Ozone generation |
0.05 ppm or less
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 300 mm 11.811 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. |
Applicable fluid |
Air (dried clean air)
(Note) Dry clean air is air that has been processed through an air dryer (freezing point around –20 ℃ –4 ! ) and an air filter (mesh size around 0.01 microm 0.0004 mil). |
Supplied air flow |
60 liter/min. (ANR) or less |
Air pressure range |
0.05 to 0.5 Mpa |
Supply voltage |
24 V DC plus or minus 10 % |
Current consumption |
120 mA or less |
Discharge method |
High frequency AC method |
Discharge output voltage |
2,000 V approx. |
Output [Check (CHECK) Error (ERROR) Discharge (DSC)]
(Note:"DSC" is an abbreviated name of "DISCHARGE".) |
NPN open-collector transistor |
• Maximum sink current: 50 mA |
• Applied voltage: 30 V DC or less (between output and 0 V) |
• Residual voltage: 1 V or less (at 50 mA sink current) |
Output:Output operation |
Check output (CHECK): ON when the discharge needle is dirty or worn, OFF when operation is normal |
Error output (ERROR): OFF when abnormal discharge is detected, ON when operation is normal |
Discharge output (DSC) (Note): ON when discharging, OFF when discharge halts
(Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’. |
Output:Short-circuit protection |
Incorporated |
Discharge halt input (DSC OFF)
(Note:"DSC" is an abbreviated name of "DISCHARGE".) |
Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start) |
Reset input (RESET) |
In the state that operation is stopped due to an error detection, open 0 V of the power supply from short-circuit state to cancel ERROR |
Indicators:Power (POWER) |
Green LED (lights up when the power is ON) |
Indicators:Discharge (DSC)
(Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’. |
Green LED (lights up when discharging) |
Indicators:Air monitoring (AIR) |
Orange LED (lights up when no air is being supplied)
(Note) Discharge halts when lights up. |
Indicators:Check (CHECK) |
Orange LED (lights up when the discharge needle is dirty or worn, etc.) |
Indicators:Error (ERROR) |
Red LED (lights up when abnormal discharge is detected) |
Ambient temperature |
0 to +55 ℃ +32 to +131 ! (No dew condensation allowed), Storage: –10 to +65 ℃ +14 to +149 ! |
Ambient humidity |
35 to 65 % RH (No dew condensation allowed), Storage: 35 to 65 % RH |
I/O connector |
For power & input / output: 8-pin connector, For connection: 9-pin connector |
Connectable units |
Maximum number of connectable units: 5 (Including this unit) |
Enclosure earthing |
Capacitor earth |
Material |
Enclosure: ABS (Nickel plated), Nozzle mount, Screw mount, Nozzle: Stainless steel. Discharge needle: Tungsten |
Weight |
Net weight: 110 g approx., Gross weight: 180 g approx. |
Accessories |
Connector attached cable: 1 pc. (length 0.5 m 1.640 ft), End connector (9-pin): 1 pc., Lead wire for connecting F.G.: 1 pc. |