AX-65

Kategori: Diffusions Pumps Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di elsotech.com.my

Penerangan

The AX-65 diffusion pump is a high-performance, air-cooled pump designed with bench-top analytical instruments in mind. Its vertical finned boiler and high power provide stable pumping and high helium pumping speed. This pump can be ordered with a cold cap or a dense baffle. The pump includes a fluid-level sight glass that indicates the fluid level at all times.

Technical Specifications

Pumping Speed, Operating Range 65 l/sec Air, 90 l/s He and H2
Maximum Throughput 0.19T-l/s (0.25 mbar-l/s) in operating range 0.30T-l/s (0.40 mbar-l/s) @ 0.01 torr  
Compression Ratio 4 x 107 (Air), 2 x 106 (helium)
Operating Range 3 x 10-3 to <5 x 10-8 torr (3.9 x 10-3 to 6.5 x 10-8 mbar)
Maximum Forepressure No load: 0.75 torr (1.00 mbar) Full Load: 0.60 torr (0.78 mbar)
Backstreaming Rate With cold cap: <2 x 10-4 mg/cm2/min With baffle: <2 x 10-5 mg/cm2/min
Recommended Backing Pump ≥1.5 cfm (2.5 m3/hr)
Warmup Time 7 minutes
Cooldown Time 10 minutes
Fluid Charge 30 cc
Electrical Requirements 1 ph, 50/60 Hz, 90/115/165/220 VAC
Pump Power 200/250 watts
Air Cooling 30 cfm

 

Speed Curve Graph

Pumping Speed/Cold Cap Pumping speed/Halo Baffle Throughput

Outline Drawing

AX-65 Diffusion Pump Outline Drawing

Description Wt. kg (lbs) Part Number
AX-65 Pumps   KF-50 ISO-6
AX-65 with standard cold cap, 115 V, 250 W 3.6 (8.0) L9670301 L9707301
AX-65 with internal baffle, 115 V, 250 W 3.6 (8.0) L9670311 L9707311
AX-65 with standard cold cap, 220 V, 250 W 3.6 (8.0) L9670302 L9707302
AX-65 with internal baffle, 220 V, 250 W 3.6 (8.0) L9670312 L9707312
AX-65 with standard cold cap, 115 V, 200 W 3.6 (8.0) L9670303 L9707303
AX-65 with internal baffle, 115 V, 200 W 3.6 (8.0) L9670313 L9707313
AX-65 with standard cold cap, 220 V, 200 W 3.6 (8.0) L9670304 L9707304
AX-65 with internal baffle, 220 V, 200 W 3.6 (8.0) L9670314 L9707314
AX-65 with standard cold cap, 90 V, 250 W 3.6 (8.0) L9670305 L9707305
AX-65 with internal baffle, 90 V, 250 W 3.6 (8.0) L9670315 L9707315
AX-65 with standard cold cap, 165 V, 250 W 3.6 (8.0) L9670306 L9707306
AX-65 with internal baffle, 165 V, 250 W 3.6 (8.0) L9670316 L9707316
 
Description Wt. kg (lbs) Part Number
Accessories
Santovac 5 diffusion pump fluid, 40 cc 0.5 (1.0) 695405001
Santovac 5 diffusion dump fluid, 65 cc 0.9 (2.0) 695405002
DC-704 diffusion pump fluid, 500 cc 1.4 (3.0) 695474005
DC-705 diffusion pump fluid, 500 cc Internal baffle kit 1.4 (3.0) 
0.9 (2.0)
695475005
R1160065
Centering ring for inlet flange, NW50 0.5 (1.0) KC50SB
Centering ring for inlet flange, ISO-63 0.2 (0.5) IC063SV
Centering ring for foreline flange, NW16 0.2 (0.5) KC16SB
Instruction manual   699901062
Replacement Parts (one heater harness required per pump)
200 W, 115 V heater harness (for use with DC-704 and DC-702) 0.5 (1.0) L9994307
250 W, 115 V heater harness (for use with DC-705 and Santovac 5) 0.5 (1.0) L9994303
200 W, 220 V heater harness (for use with DC-704 and DC-702) 0.5 (1.0) L9994308
250 W, 220 V heater harness (for use with DC-705 and Santovac 5) 0.5 (1.0) L9994304
250 W, 90 V heater harness (for use with DC-705 and Santovac 5) 0.5 (1.0) L9994301
250 W, 165 V heater harness (for use with DC-705 and Santovac 5) 0.5 (1.0) L9994302
Overtemperature thermal switch (included with each heater harness) 0.5 (1.0) L9964001