Ultimate pressure:
≤ 1 x 10-3 mbar
Pumping speed:
50÷90 m3/h
The flanged electric motor is coupled by an elastic coupling.
Cooling is achieved by forced air via a centrifugal fan.
An integrated check valve prevents the oil from coming back and the return of air into the chamber to be emptied during the stop phase.
An adjustable gas ballast prevents condensation inside the pump when small quantities of steam are sucked.
PHV 50 K and PHV 75 K pumps are suitable for evacuating closed systems or operating at a constant vacuum of up to 1 x 10-3 mbar (absolute).
ACCESSORIES
The following accessories are useful for the installation and for the control of the pump operation parameters:
|
|
|
PHV 50 K |
PHV 75 K |
|
Pumping speed |
m³/h |
50Hz |
50 |
75 |
|
60Hz |
60 |
90 |
|||
Ultimate pressure GB closed (abs) |
mbar |
|
≤ 1 x 10-3 |
≤ 1 x 10-3 |
|
Motor power |
kW |
50Hz |
1,5 |
2,2 |
|
60Hz |
|||||
Motor speed |
rpm |
50Hz |
1450 |
1450 |
|
60Hz |
1750 |
1750 |
|||
Water vapour tolerance |
mbar |
|
53 |
53 |
|
Water vapour pumping capacity |
kg/h |
|
1,97 |
2,96 |
|
Lubricant charge |
l |
|
4,5 |
6,54 |
|
Sound pressure level |
dB(A) |
50Hz |
56 |
56 |
|
60Hz |
|||||
Dimensions |
L x B x H |
mm |
50Hz |
709x250x370 |
791x280x415 |
60Hz |
|||||
Weight |
kg |
50Hz |
68 |
84 |
|
60Hz |
|||||
Connections |
Inlet |
|
40 KF |
40 KF |
|
Outlet |
|
More detail about Hexo Industries (M) Sdn Bhd