RF612 WiFi Temperature Transmitter | Comark by Muser

RF612 WiFi Temperature Transmitter | Comark by Muser

Category: Diligence 600 WiFi Transmitters Available
Purchasable on official site
For more information, visit our official website at muser.com.my

Description

Comark RF612 WiFi Temperature Transmitter
 
The Diligence 600 WiFi Temperature Transmitter is designed to monitor the ambient temperature of your storage and work areas with an integral sensor, whilst allowing for up to FOUR external points of temperature measurement to also be measured and recorded. Directly connect a single Lumberg Thermistor Probe to suit your individual requirement or add an adaptor (model RF601A) and monitor up to FOUR channels.

 
Highlights | RF612 WiFi Temperature Transmitter
 
 
WiFi Temperature Transmitter
 
Diligence 600: The WiFi Temperature Transmitter is a highly scalable solution, designed to monitor the temperature of your ambient storage and work areas with an integral sensor, whilst allowing for up to four external points of temperature measurement to also be measured and recorded.
 
Highly Scalable
Easy to scale up as and when required with a choice of Lumberg Adaptors and a host of both single and duplex probes.
 
Ambient Storage
Perfect for monitoring the temperature of your ambient storage and work areas with the integral sensor, in addition to external channels.
 
Temperature
Allows up to four external points of temperature measurement to be monitored, in addition to the ambient temperature.

 
Secure WiFi Connectivity


The Diligence 600 WiFi Monitoring System has been designed around 2.4GHz WiFi (IEEE 802.11b/g/n) technology, allowing you to use your existing WiFi infrastructure without the need for a gateway or hub device.
 
All data sent by the transmitters of your Diligence 600 WiFi Monitoring System to the Diligence Cloud, is in a non-human readable proprietary format. Transmitters open outbound TCP connections (TCP Port 8080) to send and receive TLS-encrypted data including time, recordings, alarms, settings and firmware updates. TLS is two-way using both client and server certificates, and the communication format is proprietary. Firewalls and content filters that intercept TLS traffic should not do so on this port.
 
The Diligence 600 WiFi Monitoring System devices will turn the radio signal off between WiFi transmissions. The sensors do not offer any kind of web page and will not respond to any request on any port other than required by essential network services e.g., DHCP.
 
The Diligence 600 WiFi Monitoring System devices will turn the radio signal off between WiFi transmissions and will not respond to communication.
 
 
Diligence Cloud
 
Powerful Data Storage and Management Platform


The Diligence Cloud is our most advanced data storage and management platform yet! It offers users a quick and dynamic way to access and drill-down into the data from any device that is being monitored.
 
The Diligence Cloud Dashboard View delivers a concise overview of your estate of devices, to help you resolve issues more quickly, saving products, time and money.
 
The Diligence Cloud provides secure, multi-user access to data records and audit trails, from any web-browser enabled device. It is fully scalable to meet the demands of monitoring multiple devices across multiple sites, in line with your monitoring, data logging and compliance requirements.
 
 
Technical Specifications
 

Integral Temperature Sensor Specifications:
Sensor Type Thermistor
Scales °C and °F
Temperature Measurement Range -18°C to +55°C (-0.4°F to +131°F) - See Note 1
Accuracy 0°C to +55°C (-32°F to +131°F) <±0.3°C (±0.6°F) - See Note 2
Accuracy (full range) ±0.5°C (±0.9°F) - See Note 2
Temperature Resolution 0.1°C (0.2°F)
External Probes Specifications:
Number of External Channels 4
Sensor Type Thermistor
Connector 6-Pin Lumberg
Scales °C and °F
Temperature Measurement Range -40°C to +125°C (-40°F to +257°F)
System Accuracy 0°C to +70°C (-32°F to +158°F) - including Probe <±0.3°C (±0.6°F) - See Note 2
System Accuracy -25°C to 100°C (13°F to +212°F) - including Probe ±0.5°C (±0.9°F) - See Note 2
System Accuracy (Full Range) - including Probe ±1°C (±1.8°F)
Temperature Resolution 0.1°C (0.2°F)
Common Specifications (All Models):
Hi Hi/Lo Lo Alarm - All Channels exlcuding Door Switch Hi Hi and Lo Lo Alarms with Alarm Delay and fully selectable Alarms
Alarm Delay 0-60 minutes - All Channels excluding Door Switch Delay is programmable for either H H or Hi Hi Alarms or both independently
Door Switch (Optional) Optional accessory RF521 or RF522
Door Sensor Resolution 5 seconds
Door Switch Alarms Door Switch Alarms Continuous and Average (up to 60 minutes programmable)
Ambient Operating Temperature Range -18 to +55°C (-0.4°F to 131°F) - 10-90% RH - Non-Condensing - See Note 1
Storage Temperature -18 to +55°C (-0.4°F to 131°F) - See Note 1
Wireless Frequency 2.4GHz WiFi (IEEE 802.11b/g/n)
Wireless Security WPA2 Pre-Shared Key - See Note 3
Radio Range Typically 20 metres indoors
Clock Accuracy 20ppm (1 minute/month) at +25°C (+77°F)
Logging Memory 140000 Max records - Depends on number of active channels
Log Rate Programmable between 1 minute and 60 minutes
Channel Monitoring Rate 1 Minute
Wireless Radio Rate Programmable between 5 Minutes to 24 Hours - See Note 5
Alarm/Active LEDs (Front) RED - ALARM / GREEN - External Power
Status LEDs (Side) RED - WiFi Active / YELLOW - Communications Active / GREEN - Mains Power Connected
Case Material Over Moulded food safe clear Polycarbonate with BioCote® Antimicrobial Protection
Environmental Protection Case enclosure designed to meet IP65 BS EN 60529
Battery Type 4 x AA Alkaline or Energizer MAX Lithium - See Note 4
Battery Life Up to 1 year
Dimensions Length 110mm, Height 100mm, Depth 45mm
Weight 300g
Mains PSU (Optional) Optional Mains PSU Part No RF520 (100-240VAC 0.3A 50/60Hz)
Maximum Probe Lead Length Not to exceed 30m
 
Notes:
  1. Temperature and Storage range with Energizer Lithium L91 Cells is expanded to -30 to +60°C (-22°F to +140°F)
  2. When used with a Comark Probe
  3. Other WiFi Security Options will be provided by Firmware Update
  4. Use Energizer MAX L91 for improved battery life in all applications but especially recommended for use in low temperature applications.
  5. The WiFi Rate should be set for 4 hours or greater for best battery life. This will not affect Alarm Notifications.
 
 
Downloads
 

Product Video

More detail about Muser Apac Sdn Bhd
Muser Apac Sdn Bhd
Muser Apac Sdn Bhd Testing Instruments Supplier Kuala Lumpur (KL), Malaysia, Monitoring Mapping Systems Supply Selangor, Measuring Equipments Supplies ~ Muser Apac Sdn Bhd
Contact Us flagMalaysia