Description
Heating cabinets are ideal for processes in the low temperature range up to max. 150 °C, such as for drying, preheating molds and tools or tempering and curing plastics. They have a compact design and are especially suitable for large charges. They are heated with a separate heating unit that is generally located behind the heating cabinet.
- Tmax 260 °C
- Electrically heated (via a heating register with integrated chrome steel heating elements) or gas-fired (direct or indirect gas-fired including injection of the hot air into the intake duct)
- Temperature uniformity up to +/− 3 °C according to DIN 17052-1 (for design without track cutouts)
- High-quality mineral wool insulation provides for outer temperatures of < 25 °C above room temperature
- Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
- High air exchange for fast drying processes
- Double-wing door for furnaces KTR 2300 and larger
- Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the oven and load
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
- Controller B500 (5 programs with 4 segments each)
Additional Equipment
- Base frame to charge the oven via a charging forklift
- Additional door in the back for charging from both sides or to use the oven as lock between two rooms
- Fan system for faster cooling with manual or motor-driven control of the exhaust flaps
- Programmed opening and closing of exhaust air flaps
- Air circulation with speed control, recommendable for processes with light or sensitive charge
- Observation window and furnace chamber lighting
- Safety technology according to EN 1539 (models KTR .. LS) for charges containing solvents
- Design for clean room heat treatment processes
- Rotating systems e. g. for tempering processes
- All KTR-models are also available with Tmax 300 °C
- Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
Accessories
- Adjustable plate shutters to adapt the air guide to the charge and improve temperature uniformity
Guide-in tracks and shelves
Shelves with 2/3 extraction with evenly distributed load on the whole shelve surface
Platform cart in combination with drive-in tracks
Charging cart with rack system in combination with drive-in tracks
Sealing shoes for ovens with drive-in tracks to improve temperature uniformity in the work space
Model |
Tmax |
Inner dimensions in mm |
Volume |
Outer dimensions2 in mm |
Heating power in kW1 |
Electrical |
|
°C |
w |
d |
h |
in l |
W |
D |
H |
KTR |
KTR .. LS |
connection* |
KTR 1000 (LS) |
260 |
1000 |
1000 |
1000 |
1000 |
1820 |
1430 |
1890 |
18 |
36 |
3-phase |
KTR 1500 (LS) |
260 |
1000 |
1000 |
1500 |
1500 |
1820 |
1430 |
2390 |
18 |
36 |
3-phase |
KTR 2000 (LS) |
260 |
1100 |
1500 |
1200 |
2000 |
1920 |
1930 |
2090 |
18 |
36 |
3-phase |
KTR 2300 (LS) |
260 |
1250 |
1250 |
1500 |
2300 |
2120 |
1680 |
2460 |
27 |
36 |
3-phase |
KTR 3100 (LS) |
260 |
1250 |
1250 |
2000 |
3100 |
2120 |
1680 |
2960 |
27 |
45 |
3-phase |
KTR 3400 (LS) |
260 |
1500 |
1500 |
1500 |
3400 |
2370 |
1930 |
2460 |
45 |
54 |
3-phase |
KTR 4500 (LS) |
260 |
1500 |
1500 |
2000 |
4500 |
2370 |
1930 |
2960 |
45 |
54 |
3-phase |
KTR 4600 (LS) |
260 |
1750 |
1750 |
1500 |
4600 |
2620 |
2175 |
2480 |
45 |
54 |
3-phase |
KTR 6000 (LS) |
260 |
2000 |
2000 |
1500 |
6000 |
2870 |
2430 |
2460 |
54 |
54 |
3-phase |
KTR 6125 (LS) |
260 |
1750 |
1750 |
2000 |
6125 |
2620 |
2175 |
2980 |
45 |
63 |
3-phase |
KTR 6250 (LS) |
260 |
1250 |
2500 |
2000 |
6250 |
2120 |
3035 |
2960 |
54 |
63 |
3-phase |
KTR 8000 (LS) |
260 |
2000 |
2000 |
2000 |
8000 |
2870 |
2430 |
2960 |
54 |
81 |
3-phase |
KTR 9000 (LS) |
260 |
1500 |
3000 |
2000 |
9000 |
2490 |
3870 |
2920 |
72 |
90 |
3-phase |
KTR 12300 (LS) |
260 |
1750 |
3500 |
2000 |
12300 |
2620 |
4350 |
2980 |
90 |
108 |
3-phase |
KTR 13250 (LS) |
260 |
1250 |
5000 |
2000 |
13250 |
2120 |
6170 |
2960 |
108 |
108 |
3-phase |
KTR 16000 (LS) |
260 |
2000 |
4000 |
2000 |
16000 |
2870 |
4850 |
2960 |
108 |
120 |
3-phase |
KTR 21300 (LS) |
260 |
2650 |
3550 |
2300 |
21300 |
3600 |
4195 |
3380 |
108 |
120 |
3-phase |
KTR 22500 (LS) |
260 |
2000 |
4500 |
2500 |
22500 |
3140 |
5400 |
3500 |
108 |
120 |
3-phase |
1Depending on furnace design connected load might be higher
2External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.Outer dimensions from chamber ovens KTR .. LS are different |
More detail about Obsnap Instruments Sdn. Bhd.