For slumping and bending of complex glass parts, e. g. glass furniture, shower cabins, etc., tub furnaces are the right choice. Full coverage heating: from the lid, all 4 sides and the tub bottom. Due to the modular system additional tubs in customized dimensions can be provided.
- Tmax 900 °C
- Full coverage heating: from lid, all 4 sides and bottom
- 3-zone temperature control from top to bottom for optimal temperature uniformity
- Heating elements mounted on ceramic support tubes for free heat radiation and long service life
- Bottom heating covered by SiC tiles
- Top hat insulated with high-quality fiber material; exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumino silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.
- Manual hinged lid with gas struts for easy opening and closing
- Manually operated exhaust air flaps
- Tub on wheels can be pulled out manually
- Rails on floor for perfect tub guidance included
- Defined application within the constraints of the operating instructions
Additional Equipment
- Electro-hydraulic lid instead of manual hinged lid
- Tub insert to elevate bottom height, in order to use the furnace for glass fusing applications (in this product version the tub heating can be switched off
- Automatic lid opening, can be programmed using the extra function of the controller, for faster cooling
- Motorized exhaust air flap for faster cooling
- Cooling system to assist cooling the furnace below the quartz inversion
- Interchangeable table system running on rails: to shorten process times and optimise operational capacity, two or more furnace tubs, placed alternately under the hood, can be used. An automatic tub changing system is also available on request.
- Process control and documentation via Nabertherm Control Center (NCC) for monitoring, documentation and control
Model |
Tmax |
Inner dimensions in mm |
Volume |
Outer dimensions2 in mm |
Heating |
Electrical |
Weight |
|
°C |
w |
d |
h |
in l |
W |
D |
H |
power in kW1 |
connection |
in kg |
GW 830 |
900 |
1200 |
1150 |
600 |
830 |
2140 |
1980 |
1250 |
36 |
3-phase |
820 |
GW 840 |
900 |
1650 |
850 |
600 |
840 |
2590 |
1680 |
1250 |
36 |
3-phase |
980 |
GW 1200 |
900 |
2000 |
1000 |
600 |
1200 |
2940 |
1830 |
1250 |
40 |
3-phase |
1210 |
GW 1500 |
900 |
2100 |
1150 |
600 |
1450 |
3040 |
1980 |
1250 |
70 |
3-phase |
1420 |
GW 1660 |
900 |
2300 |
1200 |
600 |
1660 |
3240 |
2030 |
1250 |
80 |
3-phase |
1780 |
GW 2200 |
900 |
2300 |
1200 |
800 |
2200 |
3240 |
2030 |
1400 |
90 |
3-phase |
2160 |
GW 8000 |
900 |
3700 |
2700 |
800 |
8000 |
4640 |
3530 |
1400 |
180 |
3-phase |
2980 |
1Depending on furnace design connected load might be higher