Description
TM-290 Multi-Field EMF Meter
Measurement Electromagnetic field
- Magnetic field(MF)
- Electric field(EF)
- RF strength
Application
The meter is equipped with three individual aerial sensors to measure EMFs.
The overload indications can be displayed simultaneously on three axes (X, Y, Z)
Features
- Display: 4 digits, 2.4 inches color TFT LCD
- Data hold (HOLD)
- Magnetic Unit: Gauss(mG) or Tesla(μT)
- RF Strength Unit: (μW/m² ~mW/m²) (μW/cm²)
- (mV/m ~V/m) (mA/m) (dBm)
- Languages: English; Traditional Chinese; Simplified Chinese; Japanese; Español
- Auto Power Off
- Audible Key Tone
- Buzzer Sound and Level High (red color) Alarm
- Brightness Options: low-Middle-high
- Low-Frequency EMF Readings: Individual and aggregated XYZ axial readings
- Historical Records: Up to 20 groups
Specifications
- Sample rate: 1 seconds per time.
- Battery life: Approximate 8 hours.
- Battery: 1.5V AAA Alkaline Battery*3.
- Operating temperature & humidity: 5°C to 40°C, below 80% RH.
- Storage temperature & humidity: -10°C to 60°C, below 70%.
- Weight: About 151g.
- Dimensions: 150(L) X 65(W) X 22(H) mm.
Electrical specifications
Specifications |
Electromagnetic field |
Electric field |
RF strength field |
Sensor type |
Low frequency
Magnetic field
Triple axis (X,Y,Z) |
LF electric field |
RF strength |
Range |
20/200/2000mG,
2/20/200µT |
50V/m~2000 V/m |
0.2µW/m²~554.6mW/m² |
Resolution |
0.02/0.1/1 mG or
0.002/0.01/0.1µT |
1 V/m |
0.01µW/m², 0.001µW/m²,
0.1mV/m, 0.1µA/cm, 1dB |
Frequency |
50/60 Hz |
50/60Hz |
50 MHz~10 GHz |
Accuracy |
± (15%+100 dgt) |
± (7%+50 dgt) |
±2 dB at 2.45 GHz |
More detail about MTM Precision Sdn Bhd