TM-1014 AC Clamp Phase
Application
It can be used for CURRENT, VOLTAGE and FREQUENCY measurements on installations of surge voltage category III up to 600 V, voltage between Phase and Earth (fixed installations) and for current measures up to 400A.Features
The apparatus can perform the following measurements:Specifications
DC Voltage | |||
Range | Resolution | Accuracy | Input impedance |
400mV | 0.1mV | ±(0.8%rdg+2dgt) | 100M!& |
4V | 1mV | 11M!& | |
40V | 10mV | 10M!& | |
400V | 100mV | ||
600V | 1V | ±(1.0%rdg+2dgt) |
AC Voltage | |||
Range | Resolution | Accuracy (50~500Hz) |
Input impedance |
400mV | 0.1mV | ±(1.0%rdg+50dgt) (at 40Hz-60Hz) |
100M!& |
4V | 1mV | ±(1.0%rdg+3dgt) | 11M!& |
40V | 10mV | 10M!& | |
400V | 100mV | ||
600V | 1V | ±(1.2%rdg+3dgt) |
AC Current | |||
Range | Resolution | Accuracy (50 ~ 60Hz) |
Overload protection |
40A | 0.01A | ±(2.0%rdg+10dgt) | 600A rms (60 seconds) |
400A | 0.1A | ±(1.5%rdg+10dgt)(0.1 – 40A) ±(1.5%rdg+3dgt)(40.1 – 400A) |
Resistance | ||||
Range | Resolution | Accuracy | Max. Open Loop voltage |
Overload protection |
400!& | 0.1!& | ±(1.0%rdg+5dgt) | about 1.5VDC |
600Vrms (60 seconds) |
4K!& | 1!& | ±(1.0%rdg+3dgt) | about 0.45 VDC |
|
40K!& | 10!& | |||
400K!& | 100!& | |||
4M!& | 1K!& | |||
40M!& | 10K!& | ±(3.0%rdg+3dgt) |
Continuity test | |||
Range | Buzzer | Max. Open Loop voltage | Overload protection |
Activated for R<40!& |
about 1.5VDC | 600V rms |
Diode test | |||
Range | Resolution | Max. Open Loop voltage |
Overload protection |
1mV | about 3.3VDC | 600V rms |
FrequenRangecy | |||
Range | Resolution | Accuracy | Voltage range |
4kHz | 1Hz | ±(0.8%rdg+3dgt) | 3V÷600V rms |
40kHz | 10Hz | ||
400kHz | 100Hz |