code: H3021P
Humidistat, thermostat with two relay outputs. T+RH probe from hard anodized duralumin for compressed air up to 25 bars. Outdoor, indoor use.
Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
The device is supplied with T+RH probe with 1m cable. Cable lengths 2m or 4m available optionally.
Included in delivery:
Technical parameters | Value |
---|---|
Output | None |
Measured Value | Temperature + Relative Humidity |
Construction Type | Compressed Air Humidity up to 2.5MPa |
Design | Industrial |
Temperature Measuring Range | -30 to 105 °C |
Relay Output | Yes |
Two-State Input | No |
Lcd Display | Yes |
PoE | No |
Maximum switching voltage, current, power of relay output | 50V, 2A, 60VA |
Audible alarm | from built-in beeper - switchable |
Relative humidity range | 0 to 100% |
Accuracy of relative humidity measurement | ±2.5% relative humidity from 5 to 95% at 23°C |
Accuracy of temperature output |
±0.4°C from -30 to +100°C ±0.4% from reading over +100°C |
Available temperature units | degrees Celsius, Fahrenheit |
Dew point temperature range | -60 to +80 °C |
Accuracy of dew point temperature output (for more details see instruction manual) | ±1.5°C for dew point temperature +10°C and higher at ambient temperature +25°C |
Accuracy of dew point temperature output | ±2.0°C for dew point temperature 0°C at ambient temperature +25°C |
Accuracy of dew point temperature output | ±3.0°C for dew point temperature -10°C at ambient temperature +25°C |
Accuracy of dew point temperature output | ±6.0°C for dew point temperature -20°C at ambient temperature +25°C |
Accuracy and range of absolute humidity output |
±1.5g/m3 at ambient temperature T < 25°C range 0 to 400 g/m3 |
Accuracy and range of specific humidity output |
±2g/kg at ambient temperature T < 35°C range 0 to 550 g/kg |
Accuracy and range of mixing ratio output |
±2g/kg at ambient temperature T < 35°C range 0 to 995 g/kg |
Accuracy and range of specific enthalpy output |
±3kJ/kg at ambient temperature T < 25°C range: 0 to 995 kJ/kg |
Temperature operating range | -30 to +80°C |
Temperature operating range of LCD display | readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C |
Temperature compensation of the humidity sensor | all temperature range |
Filtering ability of sensor cover | 0.025mm - filter with stainless steel mesh |
IP protection | IP65 electronics, IP40 sensors |
Power | 9-30Vdc, power consumption approximately 1W |
Mechanical connection of probe | G1/2 with O-Ring |
Length of the probe cable | 1m, 2m or 4m optionally |
Dimensions | 136 x 159 x 45 mm (W x H x D), probe length 150 mm, probe diameter 18mm |
Weight | approximately 450g |