A measurement system can be configured easily using CC-Link network.
It has displayable graph in the pc software, and setup can be done easily.
High-Speed A/D conversion and powerful digital processing capability of 2400 times/sec.. High display resolution of 1/100000 (max).
Measurement can be performed quickly and precisely due to high speed A/D conversion.
With communication through USB interface, logging, graph, display, setting parameters, and calibration can be done.
With combination of low pass filter (0.1 to 600Hz) which corresponds to various vibration and moving average filter (OFF, 2 to 999) that is effective for periodic vibration, automatic searching for optimal value with accuracy and stability can be achieved. (You can manually adjust settings too).
Light weight & compact body for 35mm DIN rail mount
Dimensions: 34(W)×88(H)×91(D)mm (Projections excluded)
Weight: Approx. 230g
The output signal level of load cell can be displayed in mV/V for monitor purpose.
Malfunction indicator or faulty sensor can be differentiated easily.
24 bit A/D convertor enables 6 digit display.
FA
Theoretical calibration can be performed easily by registering the capacity and rated output of load cells.
It can quickly capture any changes in high-speed phenomenon, and perform OK / NG judgement.
Analog section|Display section|Hold functions|External signal|Interface|General performance|Attachments
Analog section | |
Excitation voltage |
DC5V±5% Output current: 90mA DC2.5V±5% Output current: 45mA Ratiometric method (Up to 6 350Ω load cells can be connected in parallel) |
---|---|
Signal input range | -3.9 to 3.9mV/V |
Signal input range | Automatic adjustment by digital processing -3.0 ~ 3.0mV/V |
Span adjustment range | Automatic adjustment by digital processing 0.01 ~ 3.8mV/V |
Min. input sensitivity | 0.15μV/count |
Accuracy |
Non-linearity: within 0.01%FS Zero drift: 0.0002%FS/℃ Typ Gain drift: 1ppm/℃ Typ |
Filter |
Digital low-pass filter: 0.1 to 600 Hz Moving average filter: OFF, 2 to 999 times |
A/D converter |
Speed: 2400 times/sec. Resolution: 24bit binary |
Display section | |
Display unit | Character height 8mm, Numerical display by 7-segment green LED |
---|---|
Display value | Up to 6 digits |
Display frequency | Selectable from 1,3, 6, 13, 25 times/sec. |
Status display | RUN, SD, RD, ERR |
Hold functions | |
Hold | Sample,Peak,bottom,peak & bottom,average |
---|
External signal | |
Output signal (5) |
Transistor’s open collector output Vceo=30V, Ic=50mA |
---|---|
Input signal (3) |
Selectable/configurable Input is ON when shorted to COM terminal by contact (relay switch, etc.) or non contact (transistor, open collector, etc.). * DC24V external power supply is required. |
Interface | |
USB | USB interface |
---|---|
CCL | CC-Link interface |
SIF | SI/F 2-wire type serial interface |
General performance | |
Power supply voltage | DC24V (±15%) |
---|---|
Power consumption | 4W typ |
Operating conditions |
Temperature: Operating temperature range: -10℃ to +50℃, Storage temperature range: -20℃ to +85℃ Humidity: 85%RH or less (non-condensing) |
Dimensions | 34(W)×88(H)×91(D)mm (Projections excluded) |
Weight | Approx. 210g |
CE marking certification | EMC Directives EN61326-1 |
Attachments | |
Jumper cable | 2 |
---|---|
Mini driver | 1 |
Various I/O connector | 2 |
Quick manual | 2 |
CC-Link connector | 1 |
Product catalogue(PDF)
|
FC400-FA catalogue(1 MB) |
---|