RUIJIE RG-S2910C-24GT2XS-HP-E: RG-S2910XS 24-PORT GIGABIT POE+ L2+ MANAGED SWITCH WITH SFP+ AND EXPANSION SLOT

RUIJIE RG-S2910C-24GT2XS-HP-E: RG-S2910XS 24-PORT GIGABIT POE+ L2+ MANAGED SWITCH WITH SFP+ AND EXPANSION SLOT

分类: RUIJIE ACCESS SWITCHES 当前有货
可在官方网站购买
欲了解更多详情,请游览我们的官方网站 brwood.com.my

详情

Model: RG-S2910C-24GT2XS-HP-E
RUIJIE RG-S2910XS 24-PORT GIGABIT POE+ L2+ MANAGED SWITCH WITH SFP+ AND EXPANSION SLOT



Ruijie RG-S2910XS-E/P is a collection of next-gen Gigabit switches architected for superior security, switch delivers Non-blocking / wire-speed,high performance and outstanding energy efficiency. The series delivers full Gigabit access and unparalleled scalability to 10G performance. With the all-new hardware architecture and Ruijie’s latest RGOS11.X modular operating system, the RG-S2910XS-E/P switches offer larger table capacity, faster hardware processing performance and a better operation experience than anything previous. In addition, the PoE models in various specifications support all downlink ports running on PoE+ and fulfill high bandwidth demand of 10G uplink. The RG-S2910XS-E/P switches guarantee high-density user access and leading aggregation performance with ease.


KEY FEATURES


TECHNICAL SPECIFICATIONS


odel

RG-S2910-24GT4XS-E

RG-S2910-48GT4XS-E

RG-S2910-10GT2SFP-P-E

RG-S2910C-24GT2XS-HP-E

RG-S2910C-48GT2XS-HP-E

Ports

24 10/100/1000BASE-T ports
4 1G/10GBASE-X SFP+ ports (non-combo)

48 10/100/1000BASE-T ports
4 1G/10GBASE-X SFP+ ports (non-combo)

10 10/100/1000BASE-T ports

2 100/1000BASE-X SFP ports (non-combo)

24 10/100/1000BASE-T ports (PoE/PoE+)
2 100/1000BASE-X SFP ports (combo)
2 1G/10GBASE-X SFP+ ports (non-combo)

48 10/100/1000BASE-T ports (PoE/PoE+)
2 100/1000BASE-X SFP ports (combo)
2 1G/10GBASE-X SFP+ ports (non-combo)

Expansion Slots

N/A

N/A

N/A

2

2

Modular Power Slots

N/A

N/A

N/A

2

2

Fan Slots

Fixed

Fixed

Fanless

Fixed

Fixed

Expansion Modules

N/A

N/A

N/A

M2910-01XS
M2910-01XT
M2910-04XSÛ

M2910-01XS
M2910-01XT
M2910-04XSÛ

Management Ports

1 console port

1 console port

1 console port

1 console port
1 USB 2.0 port

1 console port
1 USB 2.0 port

Switching Capacity

264Gbps

264Gbps

256Gbps

264Gbps

264Gbps

Packet Forwarding Rate

96Mpps

132Mpps

18Mpps

96Mpps

132Mpps

Max. Number of 10GE Ports

4

4

N/A

4

4

PoE

N/A

N/A

IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking

IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking

IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking

Port Buffer

1.5MB

RAM

512MB

ARP Table

1,000

1,000

500

1,000

1,000

MAC Address

16K

Routing Table Size
(IPv4/IPv6)

500 (IPv4/IPv6)

500 (IPv4/IPv6)

64 (IPv4/IPv6)

500 (IPv4/IPv6)

500 (IPv4/IPv6)

ACL Entries

In: 1,500
Out: 500

In: 1,500
Out: 500

In: 750

Out: N/A

In: 1,500
Out: 500

In: 1,500
Out: 500

VLAN

4K 802.1q VLANs, Port-based VLAN, MAC-based VLAN, Protocol-based VLAN, Private VLAN, Voice VLAN, QinQ, IP subnet-based VLAN, GVRP, Guest VLAN

QinQ

Basic QinQ, Flexible QinQ, 1:1 VLAN switching, N:1 VLAN switching, 1:N VLAN switching

Link Aggregation

AP, LACP (maximum 8 ports can be aggregated), Cross devices AP, Flow balance

Port Mirroring

Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN, ERSPAN

# RG-S2910-10GT2SFP-P-E supports N:1/1:N port mirroring, Flow-based mirroring

Spanning Tree Protocols

IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, ROOT guard,Spanning Tree Root Guard(STRG)

DHCP

DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP snooping, IPv6 DHCP client, IPv6 DHCP relay,DHCP Snooping Option 82

Multiple Spanning Tree Protocol (MSTP) Instances

64

Maximum Aggregation Port (AP)

128

SDN

OpenFlow 1.0 & 1.3

VSU (Virtual Switch Unit)

Support (up to 9 stack members,to ensure the effectiveness of the use, 4 members are recommended* ), Local and distant stacking, Cross-chassis link aggregation in the stack, Stacking via 10G Ethernet ports

# All models support the features above except RG-S2910-10GT2SFP-P-E

Zero Configuration

CWMP(TR069)

L2 Features

MAC, EEE, ARP, VLAN, Basic QinQ, Felix QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast/Multicast/Unknown unicast storm control, IGMP v1/v2/v3 snooping, IPv6 MLD Snooping v1/v2,IGMP SGVL/IVGL, IGMP querier, IGMP filter, IGMP fast leave, DHCP, Jumbo frame, RLDP, LLDP, REUP, G.8032 ERPS, Layer 2 protocol tunnel

Layer 2 Protocols 

IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.1p, IEEE802.1x, IEEE802.3ab, IEEE802.1Q (GVRP), IEEE802.1d, IEEE802.1w, IEEE802.1s

IPv4 Features

Ping, Traceroute

IPv6 Features

ICMPv6, IPv6 Ping, IPv6 Tracert, Manually configure local address, Automatically create local address

IPv4 Routing Protocols

Static Routing, RIP, OSPF v1/v2

Basic IPv6 Protocols

IPv6 addressing, Neighbor Discovery (ND), ICMPv6, IPv6 Ping and IPv6 Tracert

IPv6 Routing Protocols

Static routing, RIPng, OSPF v3

G.8032

Support

ACL

Standard/Extended/Expert ACL, Extended MAC ACL, ACL 80, IPv6 ACL, ACL logging, ACL counter, ACL remark, Global ACL, ACL redirect, Time-based ACL, Router ACL, VLAN ACL, Port-Based ACL

QoS

802.1p/DSCP/TOS traffic classification; Multiple queue scheduling mechanisms, such as SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR; Input / output port-based speed limit; Port-based traffic recognition; Each port supports 8 queue priorities; flow-based rate limiting with the minimum granularity of 8Kbps,Dynamic QoS

Reliability

VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)

VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)

RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)

VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module

VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module

EEE Format

Support IEEE 802.3az standard

Security

Binding of the IP address, MAC address, and port address; Binding of the IPv6, MAC address, and port address; Filter illegal MAC addresses; Port-based and MAC-based 802.1x; MAB; Portal and Portal 2.0 authentication; ARP-check; DAI; Restriction on the rate of ARP packets; Gateway anti-ARP spoofing; Broadcast suppression; Hierarchical management by administrators and password protection; RADIUS and TACACS+;Change of Authorization; AAA security authentication (IPv4/IPv6) in device login management; SSH and SSH V2.0; BPDU guard; IP source guard; CPP, NFPP; Port protection, CoA(RADIUS change of authorization),SCP (Secure Copy)Dynamic ARP Inspection(DAI)

Manageability

SNMPv1/v2c/v3, CLI (Telnet / Console), RMON (1, 2, 3, 9), SSH, Syslog / Debug, NTP / SNTP, FTP, TFTP, Web, SFLOW,HTTP or HTTPS

# RG-S2910-10GT2SFP-P-E supports SNMPv2c, CLI (Telnet / Console), Syslog, RMON (1, 2, 3, 9), Web

 

Hot Patch

Support

Smart Temperature Control

Auto fan speed adjustment; Fan malfunction alerts; Fan status check

# All models support the features above except RG-S2910-10GT2SFP-P-E

 

Smart Power Supply

N/A

N/A

N/A

Support power control and management

Support power control and management

Other Protocols

FTP, TFTP, DNS client, DNS static

Dimensions
(W x D x H)  (mm)

440 × 260 × 43.6

440 × 260 × 43.6

340 × 260 × 44

440 × 320 × 44

440 × 360 × 44

Rack Height

1RU

Weight

≤3.5kg

≤4kg

<2.5kg

5.8kg (gross weight)

6.8kg (gross weight)

MTBF (hours)

 >200K

Lightning Protection on Power Port

Common Mode 6KV/Differential Mode 6KV

Common Mode 6KV/Differential Mode 6KV

Common Mode 6KV/Differential Mode 6KV

Common Mode 4KV/Differential Mode 2K

Common Mode 4KV/Differential Mode 2K

Lightening Protection on Communication Port

Common Mode 6KV

Power Supply

AC input:
Rated voltage range: 100V to 240V AC
Maximum voltage range: 90V to 264V AC
Frequency: 50/60Hz
Rated current: 1.5A

HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 0.5A to 0.1A

AC input:
Rated voltage range: 100V to 240V AC
Maximum voltage range: 90V to 264V AC
Frequency: 50/60Hz
Rated current: 1.5A

HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 0.8A to 0.5A

AC input:

Rated voltage range: 100V to 240V AC

Maximum voltage range: 90V to 264V AC

Frequency: 50/60Hz

Rated current: 2A

 

HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 1.0A to 0.4A

AC power (RG-M5000E-AC500P):
Rated voltage range: 100V to 240V AC
Frequency: 50/60Hz
Rated current range: 7A to 3.5A

HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 3.5A to 2.5A

DC power (RG-M5000E-DC500P):
Rated voltage range: -36V to -72V DC
Rated current: 16.5A

AC power (RG-RG-PA1150P-F):
Rated voltage range: 100V to 240V AC
Frequency: 50/60Hz
Rated current: 10A

HVDC input:
Input voltage range: 192V to 290V DC
Rated current range: 10A

AC power (RG-M5000E-AC500P):
Rated voltage range: 100V to 240V AC
Frequency: 50/60Hz
Rated current range: 7A to 3.5A

HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 3.5A to 2.5A

DC power (RG-M5000E-DC500P):
Rated voltage range: -36V to -72V DC
Rated current: 16.5A

AC power (RG-RG-PA1150P-F):
Rated voltage range: 100V to 240V AC
Frequency: 50/60Hz
Rated current: 10A

HVDC input:
Input voltage range: 192V to 290V DC
Rated current range: 10A

Power Consumption 

24W

50W

165W (with 8-port PoE or 4-port PoE+)

850W (with 24-port PoE+)

1700W (with 48-port PoE+)

PoE Power

N/A

N/A

125W

RG-M5000E-AC500P: 370W
RG-M5000E-DC500P: 370W
RG-PA1150P-F: 740W

RG-M5000E-AC500P: 370W
RG-M5000E-DC500P: 370W
RG-PA1150P-F: 740W

Safety Standards

IEC 60950-1, EN 60950-1

Emission Standards

EN 300 386, EN 55022/55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11

Temperature

Operating temperature: 0°C to 50°C

Operating temperature: 0°C to 50°C

Operating temperature: 0°C to 45°C

Operating temperature: 0°C to 50°C

Operating temperature: 0°C to 50°C

Storage temperature: -40°C to 70°C

Humidity

Operating humidity: 10% to 90%RH

Storage humidity: 5% to 95%RH

Operating Altitude

-500m to 5,000m

 
ADVANCE TECHNOLOGY































ENERGY SAVING











NETWORK DIAGRAM













更多 Brwood Technology 相关资料
Brwood Technology
Brwood Technology Network Infrastructure Service Selangor, System Integrator Company in KL, ICT Maintenance Malaysia ~ Brwood Technology