Item |
Data |
|
|
APPROVAL |
/ |
|
|
Test standard |
IEC61984/ UL1059 |
|
|
Pitch [mm] |
3.5 |
|
|
Poles |
04-48P |
|
|
IEC61984Test data |
/ |
|
|
Rated voltage [V] |
160 |
|
|
Rated current [A] |
8 |
|
|
Rated connection capacity)(solid/stranded) [mm²] |
0.2-1.0,1.5(sol) |
|
|
Surge voltage category/pollution degree/material group |
III/2/I |
|
|
Rated impulse voltage [KV] |
2.5 |
|
|
Rated torque [N.m] |
/ |
|
|
UL1059Test data |
UL1059 |
|
|
Use group |
B |
C |
D |
Rated voltage [V] |
300 |
/ |
/ |
Rated current [A] |
8 |
/ |
/ |
Rated connection capacity (solid/stranded) [AWG] |
24-16 |
|
|
Rated torque [Lb. in] |
/ |
|
|
General data |
/ |
|
|
Screw |
/ |
|
|
Inflammability class UL94 |
V0 |
|
|
Ambient temperature [℃] |
-40~+105 |
|
|
Relative humidity |
5%-95% |
|
|
Inspection standard |
MIL-STD-105E II |
|
|
AQL |
0.65 |
|
|
Warranty |
12 months |
|
|
Material and plating |
/ |
|
|
Housing |
PA66 |
|
|
Spring |
Stainless steel |
|
|
Contact |
Copper alloy,Sn plated |
|
|
Wire connecting |
|
|
|
Recommended stripping length 8-9mm; |
|
|
|
1.)For solid wire, stripping wire to the appointed length , put the wire into the hole |
|
|
after using the accessory depress the cage spring . |
|
|
|
2.)For stranded wire: stripping wire to the appointed length, can be directly connected |
|
or use of the corresponding standard insulated ferrule , then put the wire into the hole after |
|
using the accessory press the cage spring |
|
|
|