Coating Thickness Gauge

Coating Thickness Gauge

分类: SURFACE INSPECION 当前有货
欲了解更多详情,请游览我们的官方网站 lnbtec.com

详情

Coating Thickness Gauge

Features:

●Two thickness measuring methods adopted, the gauge can be applied to

   thickness measuring of non-magnetic coating on magnetic metal substrate

   as well as non-conductive coating on non-magnetic metal substrate;

●5 types of probes can be used (F400, F1, F10, N1, CN02,);

●2 measuring modes are available: continuing measuring mode(CONTINUE)

   and single measuring mode(SINGLE);

●2 operation modes are available: direct mode (DIRECT) and batch mode (A-B);

●5 statistic values:mean value(MEAN), max. value(MAX), min. value(MIN),

   numbers of measuring(NO.), standard deviation(S.DEV);

●2 methods can be used to calibrate the gauge, and the system error of the probe can

   be corrected by use of basic calibrating method:

●Storage function: 495 measuring values can be stored;

●Deletion function: delete the single questionable data occurring in measuring,

   as well as all of the data in memory area to perform the new measuring;

●Limit can be set: capable of alarming automatically for measuring values out of limit;

   and a batch of measuring values can be analyzed via histogram;

●Printing function: measuring value, statistic value, limit and histogram can be printed;

●Capable of communication with PC: measuring values and statistic values can be sent

   to PC to perform the further process for data;

●Indication of low voltage;

●Buzzing indication in the course of operation;

●With the function of error warning, error warning can be carried out through display or buzzing;

●Two shut down modes are available: manual shut down mode and automatic shut down mode;

 

Probe model

F400

F1

F1/90°

F5

F10

Operating principle

Magnetic induction

Measuring range (mm)

0~400

0~1250

0~5000

0~10000

Low range resolution(mm)

0.1

0.1

1

10

Accuracy

One-point calibration (mm)

±(3%H+1)

±(3%H+5)

±(3%H+10)

 

Two-point calibration (mm)

±((1~3)%H+0.7)

±((1~3)%H+1)

±((1~3)%H+5)

±((1~3)%H+10)

Measuring conditions

Min curvature radius (mm)

Convex

1

1.5

Flatten

5

10

 

Diameter of the min area (mm)

F3

F7

F7

F20

F40

 

Critical thickness of substrate (mm)

0.2

0.5

0.5

1

2

更多 LUX & BRILLIANCE TECHNOLOGIES SDN. BHD. 相关资料
LUX & BRILLIANCE TECHNOLOGIES SDN. BHD.
LUX & BRILLIANCE TECHNOLOGIES SDN. BHD. Measuring Equipment Wholesaler Malaysia, Coating Instruments Supplier Penang, Hardware Tools Supply Kuala Lumpur (KL), Selangor ~ LUX & BRILLIANCE TECHNOLOGIES SDN. BHD.