OMX_333DC ISOLATED TRANSMITTER • DC V-A > U/I

OMX_333DC ISOLATED TRANSMITTER • DC V-A > U/I

分类: DIGITAL TRANSDUCERS - DIGITAL CONVERTER / SPLITTER 当前有货
欲了解更多详情,请游览我们的官方网站 ecinstruments.net

详情

ISOLATED TRANSMITTER • DC V-A > U/I


The OMX 333 model series are simple DIN rail mountable programmable transmitters.
Type OMX 333DC is a transmitter used for measurements of higher DC voltage and current easily adjustable in the instrument´s menu.
The instrument is based on a single-chip microcontroller with a 16-bit A/D and D/A converter, which ensures good accuracy, stability and easy operation of the instrument.

  • input: ±0,5/±1/±5 A; ±25/±50/±100/±200/±400 V
  • output: 0…5/20 mA/4…20 mA
    0…2/5/10 V/±10 V
  • digital filters, tare, linearization
  • galvanic isolation: 2,5 kVAC
  • width 25 mm
  • DIN rail mounting
  • power supply 10…30 VDC/24 VAC


    TECHNICAL DATA:


    Input
    DC
    Range
    menu selectable
    0…0,5 A
    < 15 mV
    Input 5
    0…1 A
    < 30 mV
    Input 5
    0…5 A
    < 150 mV
    Input 5
    ±25 V
    10 MOhm
    Input 1
    ±25 V
    10 MOhm
    Input 1
    ±100 V
    10 MOhm
    Input 1
    ±200 V
    10 MOhm
    Input 1
    ±400 V
    10 MOhm
    Input 1
    External inputs
    Number
    1 input, on contact
    Functions
    OFF No function
    HOLD Stopping measurement (option: Display - Analog output - Limits)
    TARA Tare activation
    Projection
    Signalizing LED
    L1, L2 Limits L1, L2 (red)
    Lo, Hi Signalization, settings and errors (red/green)
    Settings
    Control
    The instrument is controlled and set by two buttons and a DIP switch on the front panel
    OM Link
    Company communication interface for operation, setting and update of device firmware
    OM Link program is also designed for visualization and filing of meas. values from more instruments
    Instrument accuracy and functionality
    Temperature coefficient
    50 ppm/°C
    Accuracy
    ±0,15 % of range (for 20 measur./s)
    Rate
    0,5…80 measur./s
    Overload capacity
    2x; 10x (t < 30 ms) - not for > 200 V and 5 A
    Linearization
    linear interpolation in 25 points (only via OM Link)
    Digital filters
    exponential mean from 2…100 measurements
    rounding setting projection step for display
    Functions
    Tare designed to reset display on non-zero input signal
    Watch-dog
    reset after 500 ms
    Calibration
    at 25°C and 40 % r.h.
    Comparators
    Type
    Digital, menu adjustable, contact connect. < 50 ms
    Mode
    Hysteresis switch. point, hysteresis band ''Mez ± 1/2 Hys.'' and time (0 ... 99.9 s) determ. switching delay
    Ready output switching signals perfect status
    Error output switching signals error status
    Output
    1x relay, switch-over contact (250 VAC/30 VDC, 3 A)
    2x relay, switch-over contact (250 VAC/30 VDC, 3 A)
    2x open collector (30 VDC/100 mA)
    4x open collector (30 VDC/100 mA)
    Data outputs
    Protocol
    ASCII
    Data format
    8 bits + no parity + 1 stop bit (ASCII)
    Rate
    600…230 400 Baud
    RS 485
    isolated, addressing max. 31 instruments
    Analogue outputs
    Type
    Isolated, programmable with a 16-bit D / A converter, type and range are menu selectable
    Temperature coefficient
    15 ppm/°C
    Nonlinearity
    ±0,1 % of range
    Rate
    response to value change < 1 ms
    Ranges
    0...2 V, 0...5 V, 0...10 V, ±10 V, 0...5 mA, 0...20 mA, 4...20 mA
    Compensation
    600 Ohm/12 V
    Error state
    at range of 4...20mA
    error message indication (<3.0 mA)
    Detection of current loop interruption
    Power supply
    Power supply
    10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
    Current draw
    < 2 W/2 VA
    Operating conditions
    Connection
    connector terminal board, cable section < 1,5 mm2
    Stabilization period
    within 15 minutes after switch on
    Operating temperature
    -20°…60°C
    Storage temperature
    -20°…80°C
    Protection class
    IP20
    El. safety
    EN 61010-1, A2
    Dielectric strength
    2,5 kVAC within 1 min. between pow. supply, input and output
    2,5 kVAC within 1 min.between input and data/anal. output
    Insulation resistance
    for polution degree II, measuring cat. III.
    power supply 550 V (ZI), 255 V (Di)*
    EMC
    EN 61326-1
    Mechanical properties
    Material
    PA 66, non-inflammable UL 94 V-I (blue)
    Dimensions
    25 x 79 x 110 mm (w x h x d)
    Installation
    DIN rail, width 35 mm

 