Class II A2 Biological Safety Cabinet, BSC-II A2

Class II A2 Biological Safety Cabinet, BSC-II A2

分类: Fumehood 当前有货
欲了解更多详情,请游览我们的官方网站 avelabsolution.com

详情

Class II A2 biological safety cabinet is biological safety isolation equipment used in biological safety labs, It can prevent harmful or unknown biological particulate aerosol from escaping during operation, it's suitable for working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.

Safety Performance:

● UV sterilization function and timing function can be set by appointment.
● Automatic air speed adjustable.
● With memory function in case of power-failure.
● Audio and visual alarm (Abnormal airflow velocity, filter failure, UV lamp failure, Front window at unsafe height).
● Interlock function: UV lamp and front window; UV lamp and blower, LED lamp; Blower and front window.

Advantages:

● Standard with air velocity sensor. Real-time monitoring and display air velocity.
● Standard with foot switch.Controls the front window to up and down.
● Standard with electric air valve control. It can be controlled through the LCD touch screen.
● Standard with RS485 interface.
● Depth of the cabinet is reduce to 780mm.Better access to the door of laboratory room.
● Unibody design for front panel.Better sealing and safer than the splice style front panel.
● Base stand with foot support for operator comfortable operation.
● Safety login system: three-level authority, control,function setting, parameter setting and hierarchical menu entry can be performed.
● Optional LED lamp with adjustable brightness.

Biological Safety Cabinet Specifications:

Model BSC-IIA2-1100 BSC-IIA2-1400 BSC-IIA2-1500 BSC-IIA2-1800
External Size (WxDxH)(mm) 1050×780×2130 1400×780×2130 1500×780×2130 1800×780×2130
Internal Size (WxDxH)(mm) 950×626×600 1300×626×600 1400×626×600 1700×626×600
Tested Opening Safety height 200mm (8”)
Max.Opening 400mm
Work Surface Height 800mm
Control System Display LCD touch screen
Alarm Abnormal airflow velocity, ULPA filter failure, UV lamp failure, Front window at unsafe height
Airflow System Airflow Mode 70% air recirculation, 30% air exhaust
Downflow Velocity 0.35m/s±0.025m/s
Inflow Velocity 0.52m/s±0.025m/s
Inflow Air Volume 355m³/h (209CFM) 486m³/h (286CFM) 524m³/h (309CFM) 636m³/h (375CFM)
Downflow Air Volume 718m³/h (423CFM) 983m³/h (579CFM) 1058m³/h (623CFM) 1285m³/h (757CFM)
Exhaust Air Volume 355m³/h (209CFM) 524m³/h (309CFM) 524m³/h (309CFM) 636m³/h (375CFM)
Air filtration System ULPA Filter 2pcs ULPA filter, ≥99.9995% efficiency at 0.1~0.3 μm, filter life indicator
Cleanliness Grade Class 100 (ISO14644.1 Class 5)
Cabinet Construction Main Body Electro-galvanized steel with antimicrobial Powder Coating
Work Surface 304 stainless steel
Front Window Motorized, Two-layer laminated toughened glass ≥ 5mm. Anti UV.
Electrical System UV Lamp 20Wx1 30Wx1 30Wx1 40Wx1
Emission of 253.7 nanometers for most efficient decontamination,UV life indicator, UV timer.
LED Lamp 16Wx2 20Wx2 20Wx2 20Wx2
Max.Consumption 750W (Not include socket loading power consumption)
Fan power 650W
Power Supply AC220V±10%, 50/60HZ; 110V±10%, 60Hz
Illumination ≥1000Lux
Sound Emission ≤60dB(A)
Standard Accessory

1. Base Stand;

2. Air Velocity Sensor;

3. ULPA Filter;

4. LCD Touch Screen;

5. LED Lamp×2;

6. UV Lamp×1;

7. Waterprof Socket×2;

8. Motorized Front Window;

9. Footmaster Caster;

10. Foot Switch;

11. Electric Air Valve Control;

12. RS485 interface

Optional Accessory

1. LED Lights With Adjustable Brightness

2. Gas Tap;

3. Water Tap;

4. IV Bar With Hooks;

5. Manual Adjustable Base Stand;

Net Weight (kg) 224 263 290 370
Gross Weight (kg) 266.5 313 380 495
Shipping Size (WxDxH)(mm) 1100x1080x1700 1550x1120x1710 1650x1120x1710 1950x1120x1710
Shipping Volume (m3) 2.3 3 3.2 3.7