Features:
·Universal AC input range/Full range
·Built-in active PFC function
·Protections: Short circuit / Over load/Over voltage/Over temperature
·Cooling by free air convection
·Class II power unit
·IP67 design for indoor or outdoor installations
·Suitable for LED lighting and moving sign applications
·Compliance to worldwide safety regulations for lighting
·Suitable for dry / damp / wet locations
·3 years warranty
Model | LPF-100-2750 | LPF-100-1750 | LPF-100-1400 | |
Output |
DC voltage | 36V | 58V | 72V |
Constant current region | 21.6~36V | 34.8~58V | 43.2~72V | |
Rated current | 2750mA | 1750mA | 1400mA | |
Rated power | 99W | 101.5W | 100.8W | |
Ripple&noise (max.) | 3.4Vp-p | 5.5Vp-p | 6.8Vp-p | |
Voltage tolerance | ±5.0% | |||
Current tolerance | ±5.0% | |||
Line regulation | ±3.0% | |||
Load regulation | ±5.0% | |||
Setup time | 1200ms/115VAC,500ms/230VAC(Full load) | |||
Input | Voltage range | 90~264VAC 47~63Hz,127~370VDC | ||
AC current (Typ.) | 0.8A/115VAC 0.4A/230VAC | |||
Efficiency | 88% | 90% | 91% | |
Power factor | PF>0.9/230VAC ,PF>0.92/115VAC(at full load) | |||
Inrush current | Cold start current 40A/230VAC | |||
Leakage current | <0.75mA/240VAC | |||
Protection |
Overload | 95~110% rated output power | ||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||
Over voltage | 42~ 46.6V | 66~ 78V | 82~ 95V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||
Short circuit | Hiccup mode, recovers automatically after fault condition is removed | |||
Over temperature |
90℃±10℃(RTH2) Protection type : Shut down o/p voltage, re-power on to recover |
|||
Environment | Working temp, humidity | -30℃~+50℃,20%~90%RH non-condensing | ||
Storage temp,humidity | -40℃~+80℃,10%~95%RH non-condensing | |||
Temp. coefficient | ±0.03%/℃ (0 ~ 50℃) | |||
Vibration | 10~500HZ,2G 10min/1cycle,period for 60min, X.Y.Z each axes | |||
Safety&EMC |
Safety standard | UL8750, TUV EN61347-1,EN61347-2-13,UL60950-1,IP67 Certificated | ||
Withstand voltage | I/P-O/P:3KVAC ,I/P-FG:1.5KVAC,O/P-FG:0.5KVAC | |||
Isolation resistance | I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH | |||
EMC interference | Compliance to EN55015,EN61000-3-2 Class C(≥65% Load) | |||
EMC emission | Compliance to EN61000-3-2 Class C(≥75% Load); EN61000-3-3 | |||
EMC immunity | Compliance to EN61000-4-2 ,3,4,5,6,8,11; ENV50204,EN55024,EN61547,light industry level (surge 4KV), criteria B | |||
Others | MTBF | 420K hrs min. MIL-HDBK-217F (25℃) | ||
Dimension | 204*49*34mm(L*W*H) | |||
Packing | 0.62kg/30pcs/19.5kg/0.027 m³/0.95CUFT |