General Specifications | |
Sensing distance | 160…2000mm |
Adjustment range | 160…2000mm |
Unusable area | 0…160mm |
Standard target plate | 100mm×100mm |
Transducer frequency | About 180kHz |
Response delay | About 195ms |
Indicators/Operating means | |
LED blue | Power on |
LED yellow |
indication of the switching state Flashing:program function object detected |
LED red |
permanently red: Error Red,flashing:program function,object not detected |
Electrical specifications | |
Operating voltage U B | 10…30VDC,ripple10%ss |
Power consumption P 0 | ≤900 mW |
Output | |
Output type | 1 analogue output 4…20mA |
Resolution | evaluation range [mm]/4000, but ≥ 0.35 mm |
Deviation of the characteristic curve |
≤0.2% of full-scale value |
Repeat accuracy | ≤0.1% of full-scale value |
Load impedance | 0…500 Ohm |
Temperature influence | ≤2% from full-scale value |
Ambient conditions | |
Ambient temperature | -25…70℃ |
Storage temperature | -40…85℃ |
Mechanical specifications | |
Protection grade | IP67 |
Connection | Connector M12x1,4-PIN |
Material Housing | brass,nickel-plated |
Transducer |
epoxy resin/hollow glass sphere mixture; Polyurethane foam |
Weight | 60g |