Water ingress protection test chamber is used to perform the tests for testing the degree of protection provided by a product enclosure.The level of protection against water ingress is represented by an IP code. All LIB test chambers fully complies with IEC 60529 (IP Code standard) and other international standards.
Our water ingress chambers have capabilitiesfor IP testing included:
Model | R-500 | R-1200 |
Internal dimensions (mm) | 800*800*800 | 1200*1200*1200 |
Overall dimensions (mm) | 1020*1360*1560 | 1450*1450*2000 |
Oscillating tube radius | 400mm | 600mm |
Spraying hole diameter | φ0.4mm | |
Hole spacing | 50 mm | |
Oscillating tube range | ±45°, ±60°, ±90°, ±180°(theoretical value) | |
Turntable rotation speed | 1r/min, or steeples speed regulating (optional) | |
Controller | Programmable color display touch screen controller | |
PC Link with software, R-232 interface | ||
Water pressure control | Flow meter | |
Observation window | Large viewing window with wiper | |
Water supply system | Storage water tank, booster pump, Automatic water supply, Water purification system, Water saving | |
Safety protection device | Electric leakage, short circuit, motor overheating | |
Standard | IEC 60529 | |
Nominal power | 4500W | 5500W |
Power | AC380V 50HZ | AC380V 50HZ |