E&M (earth & magneto, or ear & mouth) to E1 G.703 converter provides conversion between ITU-T G.703 standard E1 framed interface and 1 to 8 E&M ports.
The E&M standards were initially developed by Bell Labs and extended by national PTT administrations. The standard defines two sides to the interface:
The Signaling Unit and Trunk Circuit communicate their status over the E and M leads, using a combination of Battery and Earth (also known as Ground). The Battery signal used in the standard is nominally -48VDC. All E&M installations require that the +ve terminal of the Battery is connected to a shared reliable Earth.
The maximum distance between the Signaling Unit and the Trunk interface is determined by the resistance of the wire, but will normally be less than 100m for adequate noise immunity.
E1 interface
Interface standard:Conforms to G.703 standard
Interface rate:2048K
Code:HDB3
Interface impedance:75Ω (unbalanced), 120Ω (balanced)
Connecter:BNC (75 Ω), RJ45 (120 Ω)
Vibration characteristic:Satisfies G.742 and G.823 standard
Clock type:internal-clock, line clock
E wire
Max current:22mA
Saturation voltage:3V
Dial speed:>20pps
M wire
steady current:7 mA
min test current:5 mA
pluse dial recognition:>20pps
Physical Dimension :19inch rackmout
483(L)× 140(W)× 50(H)mm
Operation Condition
Voltage:AC180V ~ 240V;DC –48V;DC +24V
Consumption:≤5W
Operating temperature:0°C~50°C
Storing temperature:-40°C~+70°C
Relative humidity:95 %
Without disturbance of erosive and solvent gas, raising dust or strong magnetic field
AN-E1-2EM |
E1 to 2 x E&M converter, AC or DC power, E1 supports 75 or 120 ohm type |
AN-E1-4EM |
E1 to 4 x E&M converter, AC or DC power, E1 supports 75 or 120 ohm type |
AN-E1-8EM |
E1 to 8 x E&M converter, AC or DC power, E1 supports 75 or 120 ohm type |
E&M ports | Any |