Typical air compressor installation
Typical condensate management installation
Traditional separator - with gravity pre-separation
Traditional separator - with gravity pre-separation
It is a complex construction, made from many parts.
The principal of operation requires it to perform a series of processes on the condensate;
the effectiveness of each stage affects the performance of the next one.
If any one stage performs badly,the overall result is affected.
Traditional separator - with gravity pre-separation
If the filter is carbon, it must be soaked in water before installation, or its performance will be a small fraction of the rated capacity.
If oil contamination is higher than expected(high condensate flows or oil separator failure)carbon quickly becomes ineffecctive and flow is blocked.
This type od separator is usually fitted with an alarm to warm of high liquid levels caused by blocking in the separator - because that's what happens!
Effective treatment of oil-contaminated compressor ondensate for compressed air system.
Ensure a steady down slope from the outlet point to foul drain.Never discharge to storm drain or surface water.
Test outlet quality weekly usingg kit provided.Replace filter before outlet cloudiness exceeds the limit for your refion.
Water separator 60 to 7000 cfm (1.7 to 200m3/min)
Model | SEP60 | SEP120 | SEP360 | SEP900 | SEP1800 | SEP3500 | SEP7000 |
Capacity CFM | 0 - 60 (1.7) | 61 - 120 | 121 - 360 | 361 - 900 | 901 - 1800 | 1801 - 3500 | 3501 - 7000 |
Capacity m3/min | 0 - 1.7 | 1.8 - 3.4 | 3.5 - 10.2 | 10.3 - 25.5 | 25.6 - 51 | 52 - 100 | 101 - 200 |
Filter life (hours) | 4/5000 | 4/5000hr | 4/5000 | 4/5000 | 4/5000 | 16,000 | 16,000 |
This is SEP 3500 ST and SEP 7000 ST
Large capacity single separators are more efficient than using multiple installations of samaller units.
Multiple installations are expensivve to engineer, and it is almost impossible to ensure that each separator receives an equal share of condensate.The service interval is therefore ALWAYS dictated that the other are never fully utilised.
End-of-life replacement requires a new IBC,pre-filled with STERLING material.
The pressure relief chamber and connecting pipt-work is re-used.The contaminated material in the old IBC is sealed for transport to a licensed waste disposal site.Servicing is therefore both quick and clean.
Always refer to SEPURA before accepting an order - sample and site information may be needed.
Sizes are 600 litres (SEP 3500 ST) and,1,000 litres (SEP 7000 ST)