HDM 6 Intermediate through
HDM 7 Intermediate blind
Flow-rate at 6 bar DP 1 bar (Nl/min) | 00800 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Min temperature (°C) | -10 |
Operating pressure (bar) | Terminal 1-11= vacuum÷10 bar Terminal 1= 2÷7 bar |
Protection degree | IP65 |
Push-in fitting for pipe (Ø) | 8 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 ( same as the max. no. of pilots ) |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 4 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/2 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 4 |
TRA / TRR (ms) | 8 / 33 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/2 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 4 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/3 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 4 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | n°2 3/2 NC |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 4 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | n°2 3/2 NO |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 4 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 3/2 NO + 3/2 NC |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 500 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 6 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/2 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 500 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 6 |
TRA / TRR (ms) | 8 / 33 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/2 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 300 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 6 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/3 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 500 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 6 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | n°2 3/2 NC |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 500 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 6 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | n°2 3/2 NO |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 500 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 6 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 3/2 NO + 3/2 NC |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 650 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/2 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 650 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 33 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/2 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 650 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/3 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 300 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/3 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 650 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | n°2 3/2 NC |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 650 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | n°2 3/2 NO |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 650 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 3/2 NO + 3/2 NC |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 1000 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/2 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 1000 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 33 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/2 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 500 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/3 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 1000 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | n°2 3/2 NC |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 1000 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | n°2 3/2 NO |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 1000 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 3/2 NO + 3/2 NC |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 1200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/2 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 1200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 33 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/2 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 500 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 20 / 20 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 5/3 |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 1200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | n°2 3/2 NC |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 1200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | n°2 3/2 NO |
Control | PNP or NPN |
Flow-rate at 6.3 bar DP 1 bar (Nl/min) | 1200 |
Fluid | Filtered air without lubrication; lubrication, if used, must be continuos |
Insulation class | F 155 |
Max temperature (°C) | 60 |
Maximum number of pilots | 16 |
Maximum number of valves | 16 |
Min temperature (°C) | -10 |
Pilot port (Pipe Ø) | ø 4 |
Pliot pressure range | 3÷7 |
Power | 0.6 W |
Protection degree | IP 65 with common outlets |
Push-in fitting for pipe (Ø) | 8 |
TRA / TRR (ms) | 8 / 45 |
Valve pressure range | Terminal 1-11= vacuum÷10 bar Terminal 1= 3÷7 bar |
Voltage range in DC (VDC) | 24 VDC ± 10% |
Way scheme | 3/2 NO + 3/2 NC |