You can do initial setting and calibration. Installation task is easy because you can do it with confirming waveform data. PC is not required after operation is started.
When it is required, you can read and record measured value in real time by connecting a PC all the time.
It records measured value and status(Upper/Lower limit, Hold) for up to 10000 times. You can check judgment result by the OK/NG counting function.
You can pursue the cause by comparing parameter set and waveform data of NG result with the data of when it is installed.
Suitable for production line quality control such as pressure load of press or swage machine, pass or fail judgment of the automated machines and testing machines.
Analog section|Display section|Setting section|External signal|Interface|General performance|Attachments
Analog section | |
Sensor excitation voltage |
DC2.5V±10% Output current within 30mA : Standard specification 5V spec. (Please specify when ordering.) (DC5V±10% Output current within 30mA) |
---|---|
Signal input range | -3.0 to +3.0mV/V |
Equivalent input calibration range | +0.5 to +3.0mV/V |
Equivalent input calibration error | Within 0.1%FS(at 0.5mV/V input) |
Accuracy |
Non-linearity : Within 0.02%/FS(at 3mV/V input) Zero drift : Within 0.5μV/℃ RTI Gain drift : Within 0.01%/℃ |
A/D converter |
Rate : 300 times/sec. Resolution : 24 bits (binary) |
Hold function | Sample, Peak, Bottom, P-P |
Display section | |
Display | Character height 14.2mm Numerical display (4-digits), by 7-segment red LED |
---|---|
Indicated value | Numeric 4-digits -9999 to 9999 (Minus is a most significant digit. It display at the status lamp.) |
Decimal point | The display position is selectable. (8.888、88.88、888.8、8888) |
Display items |
Status display 3φ red LED ×2 (MINUS, HOLD) 3φ green LED ×1 (OK) |
Display frequency | 5, 10, 20 times/sec. selectable |
Setting section | |
Setting method | Setting by specific PC software with USB interface. |
---|---|
Preservation of data | Stored in nonvolatile RAM (NOVRAM) |
Key switch | ZERO |
Setting items |
Calibration: Zero calibration/ Span calibration (actual load calibration,equivalent input calibration) HH limit, HI limit, LO limit, LL limit, Hysteresis, Digital offset, Near zero, Comparison timing, Moving average filter, Digital low-pass filter*, Hold mode, ZERO key valid/invalid, Display frequency, Decimal place, External output selection, Indicator ID, Loadcell ID, BCD output mode, BCD data update rate, BCD output selection, D/A output mode, D/A zero scale, D/A full scale, RS-485 communication mode, RS-485 I/F setting, RS-485 ID, RS-485 transmission delay time, RS-232C communication mode, RS-232C I/F setting, Setting value LOCK (485/232), Calibration value LOCK (485/232) ※3, 6, 12Hz selectable |
External signal | |
Comparison output (2 points), Hold/judgment signal input, Digital zero signal input |
Interface | |
USB interface BCD parallel data output interface (sink type)(Option) D/A converter (current output)(Option) RS-485 communication interface (Select from Modbus-RTU and original format)(Option) RS-232C communication interface(Option) |
General performance | |
Power voltage | DC24V(±15%) |
---|---|
Power consumption | 6W max |
Inrush current |
0.7A, 18msec: DC24V average load condition (cold start at room temperature) |
Operation conditions |
Operation temperature: -10 to +40℃ Storage temperature: -40 to +80℃ Humidity:85%RH or less(non-condensing) |
Dimensions | 96(W)×48(H)×132.5(D)(mm) (not including protrusions) |
Panel cut-out dimension | 92×45(+1-0) (mm) |
Weight | Approx.550g |
Attachments | |
・Quick manual 1 ・BCD output connector(When BCD output option is selected) 1 ・Short bar(When RS-485 option is selected) 1 |
Model | Description |
BCO | BCD parallel data output interface (sink type) |
---|---|
DAI | D/A converter (current output) |
485 | RS-485 communication interface (Select from Modbus-RTU and original format) |
232 | RS-232C communication interface |
Model | Description |
CN51 | BCD output connector |
---|---|
TSU03 | DC lighting surge unit |
Product catalogue(PDF)
|
F331 catalogue(839 KB) |
---|