F350 is a digital indicator that is capable of two-channel inputs of strain gauge type sensors. Equipped with calculation functions, such as ch1+ch2, ch1-ch2, F350 is ideal for total, difference, balance and other load measurements.
Calculation and judgment outputs can be made for 2ch input values of strain gauge type sensors. Calculated value is displayed on the main display, and ch1 and ch2 input values are displayed on the sub display.
● ch1 + ch2: The ch1 value and ch2 value are added.
● ch1 – ch2: The ch2 value is subtracted from the ch1 value.
● |ch1 – ch2|: The absolute value of the difference between the ch1 value and ch2 value is calculated.
● High select: The ch1 value or ch2 value, whichever is larger, is selected.
● Low select: The ch1 value or ch2 value, whichever is smaller, is selected.
● Calculation value: HI, OK, LO
● ch1 value: HI, LO, Alarm output
● ch2 value: HI, LO, Alarm output
Including the high-speed CPU that allows processing from sensor inputs to outputs at 3000 times/sec., F350 captures necessary points reliably. (The speed can be switched to 300 times/sec.)
The indicated value can be zeroed by key operation. F350 is also equipped with the function of subtracting a set value from the indicated value. This function is convenient in the case where a no-load condition cannot be set up or for offsetting.
Voltage in proportion to the input signal, which is useful for recording with a recorder, etc., can be output on each channel.
Timing at which HI/LO limit comparison is made can be provided with a margin. This function is effective to prevent chattering, etc..
HI and LO limit output time chart (calculated value) Only HI and LO outputs are made on ch1 and ch2.
F350 is equipped with hold functions of calculated values (Sample, Peak, Valley, Average). Section setting can also be made by external signal.
Example 1) Sample hold
Example 2) All section peak hold
Example 3) Externally specified section average hold
Load and pressure are controlled at high speed with high accuracy.
Analog section|Display section|Setting section|External signal|General performance|Attachments
Analog section | |
Number of sensor inputs | 2 inputs (strain gauge input) |
---|---|
Sensor excitation | DC10V, 2.5V ±5% (It depends on the setting.), Output current: within 60mA (2 channels total) |
Signal input range | -3.0 to +3.0mV/V |
Accuracy |
Non-linearity: within 0.02%/FS ±1digit (at 3.0mV/V input) Zero drift: within 0.5μV/℃ RTI Gain drift: within 0.01%/℃ |
A/D converter |
Rate: Selectable from 3000 times/sec. and 300 times/sec. Resolution: 24 bits (binary), 1/10000 with respect to 1mV/V |
Analog filter | Low pass filter (-6dB/oct.), Selectable at 3, 30, 300, 1kHz |
Analog monitor output |
Output level: strain gauge input is approx. 2V per 1mV/V Load resistance: 2KΩ or more |
Display section | |
Display unit |
Main display: Character height 14.6mm, Numerical display by 7-segment green LED (6-digit) Sub display: Character height 8mm, Numerical display by 7-segment green LED(5-digit) |
---|---|
Indicated value |
Main display: 6-digit, ±8.8.8.8.8, -99999 to +99999, Signs: Minus sign on most significant digit Sub display: 6-digit, ±8.8.8.8.8, -19999 to +19999, Signs: Minus sign on most significant digit |
Display frequency | Selectable from 3, 6, 13 and 25 times/sec. |
Status display | HI/ OK/ LO/ PEAK/ HOLD/ HI(ch1)/ LO(ch1)/ HI(ch2)/ LO(ch2) |
Setting section | |
Setting item |
Work setting (comparison): Calculated value HI limit/ Calculated value LO limit/ ch1,2 HI limit/ ch1,2 LO limit Work setting (comparison/hold): Comparison function select/ Near zero/ Hysteresis/ Calculation hold function select/ Detection time/ Average sample number System setting (calculation/common operation): MD/ SI/F function select/ Display frequency System setting (ch operation): Digital filter/ Analog filter/ ZT/ D/Z synchronous mode/ A/D conversion speed select Calibration setting (ch calibration): Calibration function select/ Zero calibration/ Equivalent input calibration/ Actual load calibration/ Digital offset/ Digital zero limit/ Alarm HI limit/ Alarm LO limit System setting (BCO option): Output data select/ Output rate/ BCD/binary select System setting (232 option): Communication mode/ Communication condition/ Delimiter System setting (DAV/ DAI option): Output data select/ Zero scale value/ Full scale value Protect/initialize: Setting protect/ Key protect/ Initialize/ Password |
---|---|
Hold section |
Sample, Peak, Valley, Average Hold section setting (All section・External signal・External signal+Time) |
External signal | |
External input signal (4) |
hold section control/ hold release/ digital zero 1/ digital zero 2 Dry contact input circuit (minus common type), Ic=10mA or less |
---|---|
External output signal (11) |
HI/LO limit comparison (HI(calculation)・OK(calculation)・LO(calculation)・HI(ch1)・LO(ch1)・HI(ch2)・LO(ch2))/ alarm(ch1)/ alarm(ch2)/ hold complete/ RUN Open collector output circuit (sink type), Vceo=30V (max), Ic=30mA (max) |
Interface |
SIF: 22-wire type serial interface 232: RS-232C communication interface (Option) BCO: BCD parallel data output interface (Option) D3V: D/A converter voltage output (3ch) (Option) DAV: D/A converter voltage output (Option) DAI: D/A converter current output (Option) |
General performance | |
Power supply voltage | AC100V to 240V (+10% -15%) (free power source) 50/60Hz |
---|---|
Power consumption | 10W max |
Operating conditions |
Operation temperature: -10 to +40℃, Storage temperature: -40 to +80℃ Humidity: 85%RH or less (non-condensing) |
Dimensions | 96(W)×96(H)×138(D) mm (Protrusions excluded) |
Panel-cut dimensions | 92×92+1-0mm |
Weight | Approx. 1.0kg |
CE marking certification |
EMC directives: EN61326-1 Safety standard: EN61010-1, EN62311 |
Attachments | |
AC input cord (Nominal rating 125V) 3m * 1 AC input cord converter plug 1 FCN series I/O connector (with cover) 1 Ferrite core 2 BCD output connector (when BCD output option is selected) 1 Operating tool (when D/A converter(3ch) option is selected) 1 Mini driver (when D/A converter option is selected) 1 Operation manual 1 * The attached AC input cord is intended for 100V AC power in Japan. |
Model | |
BCO | BCD parallel data output interface |
---|---|
232 | RS-232C communication interface |
D3V | D/A converter voltage output (3ch) |
DAV | D/A converter voltage output |
DAI | D/A converter current output |
Model | |
CA372-I/O | Cable with FCN connector at one-end 3m |
---|---|
CAAC3P-B3 | AC Supply cord 3m |
CAAC3P-CEE7/7-B2 | AC Supply cord (Voltage resistance: 250V) 2m |
CN3P-2P | 3P-2P converter plug for AC input cord |
CN34 | D-Sub9p connector for RS-232C |
CN50 | FCN series I/O connector (with cover) |
CN51 | BCD output connector |
CN55 | BCD output connector (with diagonal cover) |
CN73 | D/A converter (3ch) connector |
CN81 | Analog I/O connector terminal |
Product catalogue(PDF)
|
F350 catalogue(650 KB) |
---|