UART digital anemometer possesses the following features:
1.Measurement of wind speed and temperature
2.Maximum/minimum/average/current wind speed selection
3.Beaufort Wind Rating
4.℃/! temperature unit selection
5.Five wind speed unit options: m/s, km/h, ft/min, knots, mph
Working current | |||
unit | min value | Typical value | max value |
mA | 7 | 8 | 10 |
Operating Voltage | |||
unit | min value | Typical value | max value |
V | 3.6 | 5 | 9.5 |
Wind temperature measurement | |||
unit | range | Resolution | Accuracy |
℃ | -10℃~50℃ | 0.2 | ±0.2℃ |
! | 14! ~122! | 0.36 | ±3.6! |
Operating temperature | 0℃~50℃(32! ~122! ) | ||
Operating humidity | 50%RH~90%RH | ||
Storage temperature | -20℃~60℃(-4! ~140! ) | ||
Storage humidity |
10%RH~90%RH |
Wind speed measurement | ||||
unit | range | Resolution | Threshold | Accuracy |
m/s | 0~45 | 0.1 | 0.3 | ± 3% ± 0. 1 dgts |
ft/min | 0~8800 | 19 | 60 | ± 3% ± 1 0dgts |
knots | 0~88 | 0.2 | 0.6 | ± 3% ± 0. 1 dgts |
km/h | 0~140 | 0.3 | 1 | ± 3% ± 0. 1 dgts |
mph | 0~100 | 0.2 | 0.7 | ± 3% ± 0. 1 dgts |
other | ||||
size | 66×29.5×178mm | |||
weight | 83.7g |