TM-507 Digital Insulation Tester
Application
This product conforms to the prescriptions of the European directive on low voltage 73/23/EEC (LVD) and to EMC directive 89/336/EEC, amended by 93/68/EEC.Features
DC Voltage measurement
|
||||
Range
|
Resolution
|
Accuracy
|
Input
Impedance
|
Overload
Protection
|
0.1~600.0V
|
0.1V
|
±(0.5%rdg+1dgt)
|
3MΩ
|
605V AC max RMS
|
AC Voltage measurement | ||||
Range | Resolution | Accuracy |
Input
Impedance
|
Overload
Protection
|
0.1~600.0V | 0.1V | ±(0.8%rdg +4dgt) | 3MΩ |
605V AC max RMS
|
Resistance measure / Test Continuity with buzzer
|
|
Range
|
0.1 - 199.9!&
|
Resolution
|
0.1 !&
|
Accuracy
|
±(2.0% rdg + 3dgt)
|
Overload protection
|
605V AC max RMS per 1 minute
|
!&0.2A : Continuity of protection conductors
|
|
Range
|
0.01 - 19.99 !&
|
Resolution
|
0.01 !&
|
Accuracy
|
(2.0% rdg + 3dgt)
|
Overload protection
|
605V max RMS
|
Test voltage
|
Range
|
Resolution
|
Accuracy
|
Overload protection
|
250V
|
0.001 - 0.100M!&
|
0.001M!&
|
±10 dgt
|
605V max RMS
|
0.101 – 3.999M!&
|
0.001M!&
|
±(2.0% rdg+5 dgt)
|
||
4.00- 39.99M!&
|
0.01 M!&
|
|||
40.0 – 399.9M!&
|
0.1 M!&
|
±(5.0% rdg+5 dgt)
|
||
400 –1000M!&
|
1M!&
|
|||
500V
|
0.001 - 0.250M!&
|
0.001M!&
|
±15dgt
|
|
0.251 – 3.999M!&
|
0.001M!&
|
±(2.0% rdg+5 dgt)
|
||
4.00- 39.99M!&
|
0.01 M!&
|
|||
40.0 – 399.9M!&
|
0.1M!&
|
|||
400- 2000M!&
|
1M!&
|
±(5.0% rdg + 5 dgt)
|
||
1000V
|
0.001 - 0.250Mv
|
0.001M!&
|
±15dgt
|
|
0.251 – 3.999Mv
|
0.001M!&
|
±(2.0% rdg+5 dgt)
|
||
4.00- 39.99M!&
|
0.01 M!&
|
|||
40.0 – 399.9M
|
0.1Mv
|
|||
400 - 1000M!&
|
1M!&
|
±(3.0% rdg+5 dgt)
|
||
1000 - 4000Mv
|
1M!&
|
±(5.0% rdg+10 dgt)
|