Testo 340 - Flue Gas Analyzer for Use in Industry [SKU 0632 3340]

Testo 340 - Flue Gas Analyzer for Use in Industry [SKU 0632 3340]

Danh mục: Industrial Emission Measurement Có sẵn
Có thể mua trên trang web chính thức
Để biết thêm thông tin, truy cập trang web chính thức của chúng tôi tại muser.com.my

Mô tả

testo 340 - Flue Gas Analyzer for Use in Industry
  Emission checks in industry: Professional technology meets practical design. The testo 340 combustion analyzer is an easy-to-use flue gas analyzer that can be fitted with up to four different gas sensors.
 

Product Description

Precise technology: That’s what you want to be able to rely on when you’re working out in the field. But precise technology is nothing if it is not versatile, easy to use and adaptable for use in the field. The testo 340 flue gas analyzer ticks all these boxes.


The testo 340 combustion analyzer. For industrial emission measurements and more 

Which sensors do you need in the course of your daily work and which measurements do you normally need to carry out? The testo 340 comes standard-fitted with an O2 sensor and four more sensors (CO, CO2, NO, NOlow, NO2 or SO2) for you to choose from, allowing you to customize your analyzer to suit your individual demands. The analyzer’s compact design and the reliable technology tucked away inside ensure increased mobility, making it ideal for use in international service operations and for installing or carrying out checks on firing plants or energy production systems. To find out more about the different application possibilities and to see which industrial applications your testo 340 flue gas analyzer is suitable for just click on the “Applications” tab.


High gas concentrations? No problem with the testo 340!

The flue gas analyzer has an extended measuring range which allows you to carry out measurements even when gas concentrations are very high (i.e. during industrial flue gas analysis). The extended measuring range (thinning) is activated automatically when high gas concentrations suddenly occur. The demands on the sensor are no different to than when the flue gas analyzer is used in low gas concentrations.
 

Delivery Scope

testo 340 flue gas analyzer, calibration certificate, shoulder strap, O2 sensor and integrated flow and pressure difference measurements.

PLEASE NOTE: Your testo 340 must be fitted with a second gas sensor for it to work. Up to three additional sensors can be fitted.
 

Technical Data


Differential Pressure - Piezoresistive
Measuring range -200 to 200 hPa
Accuracy ±0.5 hPa (-49.9 to 49.9 hPa)
±1.5 % of mv (Remaining Range)
Resolution 0.1 hPa 
 
Absolute Pressure
Measuring range +600 to +1150 hPa
Accuracy ±10 hPa
Resolution 1 hPa
 
Flue gas O
Measuring range 0 to 25 Vol.%
Accuracy ±0.2 Vol.%
Resolution 0.01 Vol.%
Reaction time t₉₀ < 20 s
 
Flue gas CO (with H-compensation)
Measuring range 0 to 10000 ppm
Accuracy ±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 10000 ppm)
Resolution 1 ppm
Reaction time t₉₀ < 40 s
 
Flue gas COlow
Measuring range 0 to 500 ppm
Accuracy ±2 ppm (0 to 39.9 ppm)
±5 % of mv (Remaining Range) data corresponds to 20°C ambient temperature. Additional temperature coefficient 0.25% of reading/K.
Resolution 0.1 ppm
Reaction time t₉₀ < 40 s 
 
Flue gas NO
Measuring range 0 to 4000 ppm
Accuracy ±5 ppm (0 to 99 ppm)
±5 % of mv (100 to 1999 ppm)
±10 % of mv (2000 to 4000 ppm)
Resolution 1 ppm
Reaction time t₉₀ < 30 s
 
Flue gas Nolow
Measuring range 0 to 300 ppm
Accuracy ±2 ppm (0 to 39.9 ppm)
±5 % of mv (Remaining Range)
Resolution 0.1 ppm
Reaction time t₉₀ < 30 s
 
Flue gas NO
Measuring range 0 to 500 ppm
Accuracy ±10 ppm (0 to 199 ppm)
±5 % of mv (Remaining Range)
Resolution 0.1 ppm
Reaction time t₉₀ < 40 s
To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
 

Flue gas SO
Measuring range 0 to 5000 ppm
Accuracy ±10 ppm (0 to 99 ppm)
±10 % of mv (Remaining Range)
Resolution 1 ppm
Reaction time t₉₀ < 40 s
To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
 

Flue gas Draught
Measuring range -40 to +40 hPa
Accuracy ±0.03 hPa (-2.99 to +2.99 hPa)
±1.5 % of mv (Remaining Range)
Resolution 0.01 hPa
 
Temperature
Measuring range -40 to +1200 °C
Accuracy ±0.5 °C (0 to +99 °C)
±0.5 % of mv (Remaining Range)
Resolution 0.1 °C
 
Flue gas degree of effectivity, Eta (calculated)
Measuring range 0 to 120 %
Resolution 0.1 %
 
Flue gas loss (calculated)
Measuring range 0 to 99.9 %
Resolution 0.1 %
 
Flue gas dewpoint (calculated)
Measuring range 0 to 99.9 °Ctd
Resolution 0.1 °Ctd
 
Flue gas CO calculation (calculated from O)
Measuring range 0 to CO max
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Reaction time t₉₀ < 40 s
 
General technical data
Dimensions 283 x 103 x 65 mm
Operating temperature -5 to +50 °C
Housing TPE PC
Protection class IP40
Warranty Measuring instrument 2 years (excepting wearing parts e.g. gas sensors, etc.); rechargeable battery: 12 months; CO sensor: 12 months; Sensor NOlow: 12 months; Sensor NO2: 12 months; Sensor SO: 12 months; Sensor O: 18 months; NO sensor 12 months; COlow sensor 12 months
Display size 160 x 240 pixels
Display function Graphic display
Power supply Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A
User defined fuels 10 user-defined fuels incl. test gas as fuel
Max. neg. press./flue gas -200 mbar
Max. pos. press./flue gas 50 mbar
Hose length max. 7.8 m (corresponds to two probe hose extensions)
Pump flow 0.6 l/min (regulated)
Maximum 100 folders
Storage per folder Max. 10 sites
Storage per site Max. 200 logs
Miscellaneous The max. number of logs is determined by the number of folders or sites
Storage temperature -20 to +50 °C
Weight 960 g
 
 
Applications
 
Analysis of the gas atmosphere (thermal processes)
Flue gas analysis is used for thermal manufacturing processes, from ongoing emission control, via setting and optimisation of combustion systems, through to process monitoring. Flue gas analysis instruments serve to optimise operations and save fuel. At the same time, flue gas measurement enables checking and monitoring of flue gas emission limit values laid down by the authorities, along with functional testing of permanently installed emission instruments. Flue gas analysis instruments are increasingly used for monitoring process and product quality.

Advantages of the testo 340

Ideal for measurements at high concentrations
When recording extremely high concentrations, the measuring range extension is automatically activated. This enables continuation of the measurement. The gas sensor is not subjected to any higher stress than it is at low gas concentrations. This ensures the sensor has the longest possible service life.
 

Service measurement on industrial engines

Flue gas analysis instruments are one of the items of equipment that are used on a daily basis by service engineers to achieve optimum tuning of engines. Flue gas measurement is used on industrial engines when they are commissioned, at regular maintenance intervals or for troubleshooting when they are running in an unstable way. The background to flue gas measurement is tuning the engine to the optimum operating parameters while complying with the limit value regulations in force. Maintenance work that is carried out regularly makes an important contribution to avoiding downtimes over the long term, to ensuring the quality of the system and thus a high level of efficiency and to having a significant influence on emission levels.

Advantages of the testo 340

Separate NO and NO2 measurement

The real NOx value is measured with the NO and NO2 sensor combination. In gas engines, the NO2 component of the NOx value can fluctuate greatly, so the separate measurement of each of the gases is necessary for correct NOx values.

Measurements even at high CO concentrations
At unexpectedly high concentrations (up to 50,000 ppm), the automatic dilution of the sensor with fresh air allows measurements even when the engine conditions are not defined, without negatively affecting the service life of the sensor.

Special flue gas probes for industrial engines as an accessory
These probes are highly heat-resistant and specially designed to compensate for different pressure conditions, e. g. for measurements before and after the catalytic converter.

Engine-specific parameters
The most important parameters for industrial engines such as O2, CO, NO, NO2, NOx and Lambda can be displayed simultaneously.
 
 
Service measurement on industrial burners

The testo 340 flue gas analysis instrument offers service engineers a vast range of technical functions. In addition to compliance with environmental regulations, it can also be used to check correct functioning and to optimise burner efficiency. Flue gas measurement is used on industrial burners for safe and efficient commissioning, at regular maintenance intervals or for troubleshooting when they are running in an unstable way.

Advantages of the testo 340

Time saving through helpful instrument pre-settings

Typical fuels, a sensible sequence of flue gas parameters in the display and useful instrument settings are preset for each application. Tips on the display take the user through the measurement (no prior knowledge specific to the instrument needed). The testo 340 is ready for operation within just a few minutes.

Unrestricted measuring at high concentrations
When commissioning burners or carrying out measurements on unfamiliar systems, very high concentrations can occur unexpectedly. The measuring range extension is automatically activated in such cases.

Always ready for use – even in tough day-to-day work
The robust housing protects the measuring instrument from knocks.
 

Downloads
 
Product Brochures

Datasheet testo 340  (PDF, 502 kB)
Product brochure testo 340  (PDF, 2.258 KB)

Manuals
Instruction manual testo 340  (PDF, 1.9 MB)
Instruction manual testo 340  (PDF, 4.9 MB)
Instruction manual testo 340 old  (PDF, 1.1 MB)
 

Xem thêm chi tiết về Muser Apac Sdn Bhd
Muser Apac Sdn Bhd
Muser Apac Sdn Bhd Testing Instruments Supplier Kuala Lumpur (KL), Malaysia, Monitoring Mapping Systems Supply Selangor, Measuring Equipments Supplies ~ Muser Apac Sdn Bhd