HI801-02 iris Visible Spectrophotometer

HI801-02 iris Visible Spectrophotometer

Danh mục: Spectrophotometers IRIS Có sẵn (Số lượng:1)
Có thể mua trên trang web chính thức
RM 17505.00 Để biết thêm thông tin, truy cập trang web chính thức của chúng tôi tại hannamalaysia.com

Mô tả

 

Spectrophotometer

with split beam optical system, customizable methods, and rechargeable battery

 

The iris portable spectrophotometer is unlike any of the products we have created in the past. It is different from our photometers as it allows for measurement in the spectrum of all wavelengths of visible light and not just pre–specified wavelengths. Spectrophotometers work by isolating light at specific wavelengths from white light. This compact meter incorporates a number of features that facilitate both fantastic performance and exceptional usability.

Superior design for superior results.

iris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm.

With the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.

 

No need for measurement conversions.

Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.

 

The convenience of pre-programmed methods with the option to expand.

iris comes pre-programmed with more than 80 commonly used chemical analysis methods to help you get started. Simply update these methods by connecting to a computer or flash drive.

Customize your iris with up to 100 personal methods. iris will guide you through the method creation process step-by-step. For added versatility, each method can include up to 10 calibration points, five different wavelengths, and up to five reaction timers.

Easily access your favorite methods directly from the home screen to save time.

Built in timers make make measuring seamless. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between measurements and users. If you get stuck, the tutorial mode will walk you through the steps.

 

Change sample size easily.

With our universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.

 

Round Vial Square

 

Worry free replacements.

iris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.


 

Designed for dynamic environments.

iris' compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3,000 measurements, or 8 hours – well over a full day of use out in the field.

 

 

Quality data without the hassle.

Export your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.

 

Menu navigation that makes sense.

Quickly navigate between screens with custom keys, and access your favorite methods directly from the home screen with our “favorite methods” feature.

 

Sort and share your data.

Save data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that's best for you.

All of your important information is easily visible.

With a 6” display, the screen is large and easy to read. The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements.

 

Zero resistance with a capacitive touch pad.

Menu buttons are part of the display. Built to be fully sealed and easy to clean, the meter recognizes key touches even through gloves.

 

Specification: 

 

More Information
SKU HI801-02
Product Name iris Visible Spectrophotometer - HI801
Quote Required Yes
pH Range 6.5 to 8.5 pH
pH Resolution 0.1 pH
pH Accuracy ±0.1 pH
pH Method Adaptation of the Phenol Red method
Dissolved Oxygen Range 0.0 to 10.0 mg/L (as O2 )
Dissolved Oxygen Resolution 0.1 mg/L
Dissolved Oxygen Accuracy ±0.4 mg/L ±3% of reading
Dissolved Oxygen Measurement Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
Absorbance Range 0.000 to 3.000 Abs
Absorbance Resolution 0.001 Abs
Absorbance Accuracy 5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs
Alkalinity Range 0 to 500 mg/L (as CaCO3 )
Alkalinity Resolution 1 mg/L
Alkalinity Accuracy ±5 mg/L ±5% of reading
Alkalinity Method Colorimetric Method
Seawater Alkalinity Range 0 to 300 mg/L (as CaCO3 )
Seawater Alkalinity Resolution 1 mg/L
Seawater Alkalinity Accuracy ±5 mg/L ±5% of reading
Seawater Alkalinity Method Colorimetric Method
Aluminum Range 0.00 to 1.00 mg/L (as Al3+)
Aluminum Resolution 0.01 mg/L
Aluminum Accuracy ±0.04 mg/L ±4% of reading
Aluminum Method Adaptation of the aluminon method.
Ammonia Range Low Range
Ammonia Resolution Low and Medium Range
Ammonia Accuracy Low Range
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method.
Anionic Surfactants Range 0.00 to 3.50 mg/L (as SDBS)
Anionic Surfactants Resolution 0.01 mg/L
Anionic Surfactants Accuracy ±0.04 mg/L ±3% of reading
Anionic Surfactants Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS
Bromine Range 0.00 to 8.00 mg/L (as Br2 )
Bromine Resolution 0.01 mg/L
Bromine Accuracy ±0.08 mg/L ±3% of reading
Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Calcium Range 0 to 400 mg/L (as Ca2+)
Calcium Resolution 1 mg/L
Calcium Accuracy ±10 mg/L ±5% of reading
Calcium Method Adaptation of the Oxalate method
Carbon Dioxide Range 0.00 to 2.00 mg/L (as ClO2 )
Carbon Dioxide Resolution 0.01 mg/L
Carbon Dioxide Accuracy ±0.10 mg/L ±5% of reading
Carbon Dioxide Method Adaptation of the Chlorophenol Red method
Chemical Oxygen Demand Range Low Range
Chemical Oxygen Demand Resolution 1 mg/L
Chemical Oxygen Demand Accuracy Low Range
Chemical Oxygen Demand Method Adaptation of the USEPA 410.4
Chloride Range 0.0 to 20.0 mg/L (as Cl)
Chloride Resolution 0.1 mg/L
Chloride Accuracy ±0.5 mg/L ±6% of reading
Chloride Method Adaptation of the mercury(II) thiocyanate method
Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2 )
Chlorine Dioxide Resolution 0.01 mg/L
Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading
Chlorine Dioxide Method Adaptation of the Chlorophenol Red method
Free Chlorine Range Ultra Low Range
Free Chlorine Resolution Ultra Low Range
Free Chlorine Accuracy Ultra Low Range
Total Chlorine Range Ultra Low Range
Total Chlorine Resolution Ultra Low Range
Total Chlorine Accuracy Ultra Low Range
Chromium, Hexavalent Range Low Range
Chromium, Hexavalent Resolution Low Range
Chromium, Hexavalent Accuracy Low Range
Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method
Color, Water Range 0 to 500 PCU (Platinum Cobalt Units)
Color, Water Resolution 1 PCU
Color, Water Accuracy ±10 PCU ±5% of reading
Color, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method
Color, Maple Syrup Range 0.00 to 100.00 %T
Color, Maple Syrup Resolution 0.01 %T
Color, Maple Syrup Accuracy ±3% of reading
Color, Maple Syrup Method Direct measure
Copper Range Low Range
Copper Resolution Low Range
Copper Accuracy Low Range
Copper Method Adaptation of the EPA method
Cyanide Range 0.000 to 0.200 mg/L (as CN-)
Cyanide Resolution 0.001 mg/L
Cyanide Accuracy ±0.005 mg/L ±3% of reading
Cyanide Method Pyridine-Pyrazalone
Cyanuric Acid Range 0 to 100 mg/L (as CYA)
Cyanuric Acid Resolution 1 mg/L
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading
Cyanuric Acid Method Adaptation of the turbidimetric method
Fluoride Range Low Range
Fluoride Resolution Low Range
Fluoride Accuracy Low Range
Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
Hardness, Total Range Low Range
Hardness, Total Resolution 1 mg/L
Hardness, Total Accuracy Low Range
Hardness, Total Method Adaptation of the EPA recommended method 130.1
Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3 )
Hardness, Calcium Resolution 0.01 mg/L
Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
Hardness, Magnesium Range 0.00 to 2.00 mg/L (CaCO3 )
Hardness, Magnesium Resolution 0.01 mg/L
Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method
Hydrazine Range 0 to 400 µg/L (as N2H4 )
Hydrazine Resolution 1 µg/L
Hydrazine Accuracy ±4% of full scale reading
Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method
Iodine Range 0.0 to 12.5 mg/L (as I2 )
Iodine Resolution 0.1 mg/L
Iodine Accuracy ±0.1 mg/L ±5% of reading
Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Iron Range Low Range
Iron Resolution Low Range
Iron Accuracy Low Range
Iron Method Low Range
Magnesium Range 0 to 150 mg/L (as Mg2+)
Magnesium Resolution 1 mg/L
Magnesium Accuracy ±5 mg/L ±3% of reading
Magnesium Method Adaptation of the Calmagite method
Manganese Range Low Range
Manganese Resolution Low Range
Manganese Accuracy Low Range
Manganese Method Low Range
Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution 0.1 mg/L
Molybdenum Accuracy ±0.3 mg/L ±5% of reading
Molybdenum Method Adaptation of the mercaptoacetic acid method
Nickel Range Low Range
Nickel Resolution Low Range
Nickel Accuracy Low Range
Nickel Method Low Range
Nitrate Range 0.0 to 30.0 mg/L (as NO3 - N)
Chromotropic Acid
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Chromotropic Acid
Nitrate Method Adaptation of the cadmium reduction method
Chromotropic Acid
Nitrite Range Marine Ultra Low Range
Nitrite Resolution Marine Ultra Low Range
Nitrite Accuracy Marine Ultra Low Range
Nitrite Method Marine Ultra Low Range
Nitrogen, Total Range Low Range
Nitrogen, Total Resolution Low Range
Nitrogen, Total Accuracy Low Range
Nitrogen, Total Method Chromotropic acid method
Oxygen, Scavenger Range Carbohydrazide
Oxygen, Scavenger Resolution Carbohydrazide
Oxygen, Scavenger Accuracy Carbohydrazide
Oxygen, Scavenger Method Adaptation of the iron reduction method
Ozone Range 0.00 to 2.00 mg/L (as O3 )
Ozone Resolution 0.01 mg/L
Ozone Accuracy ±0.02 mg/L ±3% of reading
Ozone Method Colorimetric DPD Method
Phosphate Range Low Range
Phosphate Resolution Low Range
Phosphate Accuracy Low Range
Phosphate Method Low Range
Phosphorous, Acid Hydrolyzable Range 0.00 to 1.60 mg/L (as P)
Phosphorous, Acid Hydrolyzable Resolution 0.01 mg/L
Phosphorous, Acid Hydrolyzable Accuracy ±0.05 mg/L or ±5% of reading
Phosphorous, Acid Hydrolyzable Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.
Phosphorous, Reactive Range Low Range
Phosphorous, Reactive Resolution Low Range
Phosphorous, Reactive Accuracy Low Range
Phosphorous, Reactive Method Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.
Phosphorous, Total Range Low Range
Phosphorous, Total Accuracy Low Range
Phosphorous, Total Resolution Low Range
Phosphorous, Total Method Low Range
Potassium Range Low Range
Potassium Resolution Low Range
Potassium Accuracy Low Range
Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method
Silica Range Low Range
Silica Resolution Low Range
Silica Accuracy Low Range
Silica Method Low Range
Silver Range 0.000 to 1.000 mg/L (as Ag)
Silver Resolution 0.001 mg/L
Silver Accuracy ±0.020 mg/L ±5% of reading
Silver Method Adaptation of the PAN method
Sulfate Range 0 to 150 mg/L (as SO42-)
Sulfate Resolution 1 mg/L
Sulfate Accuracy ±5 mg/L ±3% of reading
Sulfate Method Sulfate is precipitated with barium chloride crystals
Zinc Range 0.00 to 3.00 mg/L (as Zn)
Zinc Resolution 0.01 mg/L
Zinc Accuracy ±0.03 mg/L ±3% of reading
Zinc Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
Wavelength Range 340 to 900 nm
Wavelength Resolution 1 nm
Wavelength Accuracy ±1.5 nm
Measurement Modes Transmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, ºf, ºe, ppb, meq/L, μg/L, PCU, Pfund, pH, dKH, ºdH, meq/kg or no measurement unit)
Wavelength Selection automatic, based on the selected method (editable for user methods only)
Optical System split beam sample and reference light detectors
Wavelength Calibration internal, automatic at power-on, visual feedback
Data Points Stored up to 9999 measured values
Export Capability .csv file format, .pdf file format
Connectivity (1) USB - A (mass storage host); (1) USB - B (mass storage device)
Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
Battery Type/Life 3000 measurements or 8 hours
Environment 0 to 50 °C (32 to 122 °F); 0 to 95% RH
Weight 3 kg (6.6 lbs)
Dimensions 155 x 205 x 322 mm (6.1 x 8.0 x 12.6'')
Ordering Information HI801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.


 

Xem thêm chi tiết về Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd Measuring Instruments Selangor, Photometers Supply Penang, Sabah, Test Equipments Supplier Malaysia ~ Hanna Instruments (M) Sdn Bhd