The MQMe quantometer is based on the principle of a turbine flow meter with an integrated electronic index head. The MQM is designed for flow and volume measurement for natural gas, nitrogen, air (and other gases on request) in non-custody transfer and process applications. The MQM is available in sizes from DN 25 (1´´) to DN 150 (6´´) with a volume flow rate up to 1600 m3/h depending on meter size. The meter housing is made of high strength aluminum. Itis designed as a sandwich construction (installed between two flanges). A volume correction function (AGA NX-19) can be optionally integrated in the electronic index head. Several communication options are available for data transmission: RS 485, M-Bus, Modbus, HF and LF signal as well as a 4 to 20 mA output. On a standard basis the MQMe meter is battery powered with a calculated battery life time of 5 years under standard conditions.
Sizes: | 1' (DN25) to 6' (DN150) |
Connections: | |
Materials: | Meter body anodized aluminium / Meter head made of polymer material or aluminium (optional) |
Flow Rates: | 16 to 1600 m³/h |
Medium: | Gas |
Pressure Class: | PN10/PN16 or ANSI Class 150 |
Temperature: | |
Approvals: | PED and ATEX (zone 1) |