Specifications |
Voltage DC |
Maximum Voltage: |
1000 V |
Accuracy: |
1577: ±(0.2%+2) |
|
1587: ±(0.09%+2) |
Maximum Resolution: |
0.001V |
|
Voltage AC |
Maximum Voltage: |
1000 V |
Accuracy: |
1577: ±(2%+3) |
|
1587: ±(2%+3) |
AC Bandwidth: |
1587: 5kHz* |
|
*with low pass filter; 3db @ 800 Hz |
Maximum Resolution: |
0.1 mV |
|
Current DC |
Maximum Amps: |
400mA |
Amps Accuracy: |
1577: ±(1.0%+2) |
|
1587: ±(0.2%+2) |
Maximum Resolution: |
0.01 mA |
|
Current AC |
Maximum Amps: |
400mA |
Amps Accuracy: |
1577: ±(2.0%+2)* |
|
1587: ±(1.5%+2)* |
|
* 1kHz bandwidth |
Maximum Resolution: |
0.01 mA |
|
Resistance |
Maximum Resistance: |
50 MΩ |
Accuracy: |
1577: ±(1.2%+2) |
|
1587: ±(0.9%+2) |
Maximum Resolution: |
0.1Ω |
|
Capacitance(1587 only) |
Maximum Capacitance: |
9,999 µF |
Accuracy: |
±(1.2%+2) |
Maximum Resolution: |
1 nF |
|
Frequency (1587 only) |
Maximum Frequency: |
100 kHz |
Accuracy: |
±(0.1%+1) |
Maximum Resolution: |
0.01 Hz |
|
Temperature Measurement (1587 only) |
|
-40.0 °C to 537 °C |
|
-40.0 °F to 998 °F |
|
excluding probe |
|
Diode Test (1587 only) |
Range: |
6 V |
Resolution: |
1 mV |
Accuracy: |
±(2 % + 1) |
|