Technical Specifications |
DCV |
Maximum Voltage: |
1000V |
Accuracy: |
Fluke 88 V: ±(0.1%+1) |
Best Resolution: |
Fluke 88 V: 0.01 mV |
|
ACV |
Maximum Voltage: |
1000V |
Accuracy: |
Fluke 88 V: ±(0.5%+2) |
AC Bandwidth: |
Fluke 88 V: 5kHz |
Best Resolution: |
0.01 mV |
|
DC Current |
Maximum Amps: |
10A |
Amps Accuracy: |
Fluke 88 V: ±(0.4%+2) |
Best Resolution: |
Fluke 88 V: 0.001 mA |
|
AC Current |
Maximum Amps: |
10A |
Amps Accuracy: |
Fluke 88 V: ±(1.2%+2) |
Best Resolution: |
0.001 mA |
|
Resistance |
Maximum Resistance: |
50 MΩ |
Accuracy: |
Fluke 88 V: ±(0.4%+1) |
Best Resolution: |
0.1Ω |
|
Capacitance |
Maximum Capacitance: |
9,999 µF |
Accuracy: |
±(1%+2) |
Best Resolution: |
0.01 nF |
|
Frequency |
Maximum Frequency: |
200 KHz |
Accuracy: |
±(0.005%+1) |
Best Resolution: |
0.01 Hz |
|
Duty Cycle |
Maximum Duty Cycle: |
99.9 % |
Accuracy: |
within 2% per KHz +0.1% |
Best Resolution: |
0.1 % |
|
Temperature Measurement |
|
-200.0°C - 1090°C |
|
-328.0°F - 1994.0°F, 1.0% excluding probe |
|
80 BK Temperature Probe |
|
-40 °C - 260 °C |
|
-40 °F - 500 °F, 2.2 °C or 2% whichever is greater |
|
Conductance |
Maximum Conductance: |
60.00 nS |
Accuracy: |
±(1.0%+10) |
Maximum Resolution: |
0.01 nS |
|
Operating Range |
Operating Temperature: |
-20 °C - 55 °C |
Storage Temperature: |
-40 °C - 60 °C |
|
Physical |
|
5.2 cm x 9.8cm x 20.1 cm (2.06” x 3.86” x 7.93”) |
|
624 g (22 oz.) |
|