Agilent / Varian PHD-4 Sniffer

Agilent / Varian PHD-4 Sniffer

Danh mục: Portable Sniffer Có sẵn
Để biết thêm thông tin, truy cập trang web chính thức của chúng tôi tại hexoind.com

Mô tả

Agilent / (previously is Varian) PHD-4 Sniffer Helium Leak Detector

The Agilent / (previously is Varian) PHD-4 sniffer helium leak detector is able to detect very small leaks in objects that have a slight helium/air pressure inside. The lightweight and rugged sniffer is sensitive to helium concentrations as small as 2 ppm- equivalent to a leak rate of 5x 10-6 atm-cc/sec, far superior to the performance by other means of detecting leaks, such as bubble-testing. The PHD-4 sensitivity relies on Agilent’s proprietary and patented SIPD (Selective Ion Pump Detection) technology. Since it is controlled by a microprocessor, the PHD-4 is easy to use with no training required. All tuning and zeroing are handled automatically. 

Features
  • The PHD-4 weighs only 2,6 Kg (5.7 lbs) including the battery
  • Wide range of uses: Replaces or can be used with existing methods such as bubble test or pressure decay
  • State-of-the-art microprocessor control allows great simplicity of operation
  • Fully automatic start-up
  • Ready for test in less than 3 minutes
  • Excellent selectivity for helium allows you to read helium leaks and ignore all other gases
  • Helium sensitivity can be adjusted as required to minimize test costs and helium consumption
  • Can operate either on battery power or connected to an outlet line voltage
  • The display can be set to use any of four languages (English, French, Germany, or Italian)
Specifications
Tech Specs
 
Lowest detectable helium concentration 2 parts per million (ppm)
Smallest detectable leak 5 × 10-6 atm-cc/sec
5 × 10-6 mbar-l/sec
5 × 10-7 Pa-m3/sec
Response time <2 seconds
Recovery time (from 50 to 0 ppm) <10 seconds
Start-up time, including self-check 3 minutes (approximate)
Power requirements 12 VDC from battery pack, car battery, or transformer
Transformer power supply 110-240V 50-60 Hz
Sealed, detachable battery pack 4 hours of operation with full charge
Ambient storage temperature -20 to +60 °C (4 to 140 °F)
Ambient operating temperature -5 to +35 °C (20 to 95 °F)
Maximum relative humidity 90%
Weight, basic module with battery 5.7 lbs (2.6 kg)
Background suppression (zeroing) Automatic
Tuning Automatic

Order Information :

PHD-4 Complete Package            Part Number : 9694640
Travel Case includes 
• PHD-4 basic unit
• Spare battery
• Transformer/Battery charger (110-240 V)
• Carrying strap
• Probe set
• 15-pin I/O connector
• CD Instruction manual

PHD-4 Basic Package                   Part Number : 9694600
Includes 
• PHD-4 basic unit
• Transformer/Battery charger (110-240 V)
• Carrying strap
• 15-pin I/O connector
• CD Instruction manual

PHD-4 Replacement Part Kit        Part Number : 9694660
Includes 
• Sampling pump with fittings
• Probe with sampling line
• Tip probe filter
• Internal filter (kit of 5 units)

Accessories                                                                 Part Number
• Probe set                                                                     9693515
• Capillary leak with refillable reservoir and gauge        9693540
• Probe with 10 meter (30’) maximum sampling line     9693525
• Telescoping extension probe                                      9693520

Individual Replacement Parts                                    Part Number
• Spare battery                                                              SR03702609
• Power supply (110-240 V)                                          SR03702888
• Sampling pump with fittings                                       SR03702513
• Probe with sampling line                                            SR03702538
• Tip probe filter                                                            SR2890001201
• Internal filter (kit of 5 units)                                        SR03702959
• Carrying strap                                                            SR03702791
• 15-pin I/O connector                                                  SR03702894
• Travel Case (metal)                                                   SR03702890
• Protective Bag (canvas)                                            VSPHD4BAG
 
-

Reasons for using our Helium Leak Detectors for Fine Leak Testing
Leak testing is crucial because, well, everything leaks! Here are the fundamental reasons for performing leak tests:
  1. Preventing Material Loss by Leakage Detecting and addressing leaks ensures that valuable materials are not lost due to escaping gases.
  2. Avoiding Contamination Leaks can introduce contaminants into a system, affecting product quality and reliability.
  3. Ensuring Product Performance and Reliability Leak-free products perform better and are more reliable, leading to satisfied customers.
  4. Reducing Liability Leaks can lead to safety hazards, environmental issues, and legal liabilities.
  5. Minimizing Production Output Loss System downtime caused by leaks can significantly impact production output.
All of these factors contribute to improved quality and reduced warranty costs.
 

Why Hexo Uses Helium as a Tracer Gas?
Why Choose Hexo:
 
Hexo Helium Leak Detectors are available for sale in Malaysia, Indonesia, Philippines, Vietnam, Singapore, Thailand, and the South East Asia Region.

Xem thêm chi tiết về Hexo Industries (M) Sdn Bhd
Hexo Industries (M) Sdn Bhd
Hexo Industries (M) Sdn Bhd Measuring Instruments Supplier Malaysia, Leak Detection Systems Supply Penang, Power Tools Supplies Singapore, Indonesia ~ Hexo Industries (M) Sdn Bhd