Carrier® ChillerVu™ Chilled Water System Optimizer OPN-OPT-OL

Carrier® ChillerVu™ Chilled Water System Optimizer OPN-OPT-OL

Danh mục: Carrier Có sẵn
Để biết thêm thông tin, truy cập trang web chính thức của chúng tôi tại unitedfaith.com.my

Mô tả

The Carrier® ChillerVu™ chilled water system optimizer is a sophisticated, scalable, native BACnet plant optimization solution for chiller plants. The chilled water system optimizer minimizes the energy use of the entire chilled water system, up to and including air handling units. The factory-engineered control program is designed to provide a supervisory level of control over the chilled water production of the chiller plant, managing the plant chilled water supply temperature and the condenser water supply temperature to provide optimal energy usage while maintaining occupant comfort in the building.

The Carrier chilled water system optimizer seamlessly interfaces with Carrier’s ChillerVu plant system manager, further improving efficiency for plants consisting of Carrier 19, 23, or 30 series chillers (air or water-cooled) and non- Carrier chillers. Setpoint, plant status, machine energy consumption and other system data are easily exchanged between ChillerVu and the chilled water system optimizer.


carrier-bacnet-international-member
carrier-bacnet-testing-laboratories




 
 

Features

System Benefits

Energy Savings

Software Features

Robust Control Features


Specifications

BACnet Support Advanced Application Controller (B-BC), as defined in BACnet 135-2012 Annex L, Protocol Rev. 9
Communication Ports Ethernet Port (E1): 10/100 BaseT Ethernet port for LAN, BACnet/Ethernet, BACnet/IP, and/or Modbus TCP/IP communications
BACnet Port: ARC156 communication port
Port S1: EIA-485 port for BACnet MS/TP @ 9600, 19200, 38400, and 76800 baud
Port S2: Configurable EIA-485/EIA-232 port for third party network connections, including:
» BACnet MS/TP @ 9600, 19200, 38400, and 76800 baud
» Modbus (RTU and ASCII modes) @ 9600, 19200, 38400, and 76800 baud
Local Access Port: For system start-up and troubleshooting (115.2 kbps)
Rnet Port: For connecting Carrier communicating room sensors and Carrier’s touchscreen interface
Protection Incoming Power: Replaceable 3 Amp Pico® fuse
Network: Non-replaceable internal solid-state polyswitches that reset themselves when fault clears. The power, network, and I/O are also protected against voltage transient and surge events.
Battery 10-year Lithium CR123A battery provides a maximum of 720 hours of time retention during power outages.
Status Indicators LED status for communications and low battery. 7-segment status display for running, error, and power.
Listed By UL-916 (PAZX), cUL-916 (PAZX7), CE, FCC Part 15-Subpart B-Class A.
Addressing Rotary DIP switches set MAC address of controller
Real-Time Clock Battery-backed real time clock.
Environmental Operating Range Operating: 0 to 140ºF (-18 to 60ºC); 0 to 90% RH, non-condensing
Storage: -20 to 140ºF (-29 to 60ºC); 0 to 90% RH, non-condensing
Power Requirements 24VAC ± 10%, 50-60Hz
24 VA power consumption
26VDC (25V min, 30V max), 10W
Dimensions Overall
A: 7-1/2” (19.1 cm)
B: 11-3/8” (28.9 cm)

Mounting
C: 5” (16.38 cm)
D: 10-7/8” (27.6 cm)
E: 1-1/4” (3.2 cm)
F: 1/4” (.6 cm)

Depth: 1-1/2” (3.8 cm)
Weight: 1.4 lbs. (.64 kg)

Xem thêm chi tiết về United Faith Sdn Bhd
United Faith Sdn Bhd
United Faith Sdn Bhd Air Conditioner Parts Supplier Selangor, Air Cond Services Kuala Lumpur (KL), Refrigeration Tools Malaysia, Singapore ~ United Faith Sdn Bhd