Gemini® Split-System Heat Pump 38AUQ with Puron® Refrigerant 6 to 20 Nominal Tons

Gemini® Split-System Heat Pump 38AUQ with Puron® Refrigerant 6 to 20 Nominal Tons

Danh mục: Carrier Có sẵn
Để biết thêm thông tin, truy cập trang web chính thức của chúng tôi tại unitedfaith.com.my

Mô tả

with Puron® Refrigerant

6 to 20 Nominal Tons

The Gemini® 38AU series outdoor units and matched with the 40RU series indoor air handlers offer a wide variety of options for your HVAC application needs. This series is designed for long dependable operation whether it's a rooftop or on-the-ground installation. All GEMINI 38AU Condensing Units and 40RU Fan Coils use environmentally sound Puron® refrigerant. Together, they create a reliable split system that provides easy solutions to a wide range of commercial HVAC needs.


carrier-AHRI-340-360-Unitary-Large-AC
carrier-intertek-ETL-listed-C-US
carrier-c-ul-us
carrier-ASHRAE-90-1-certification

Performance Features

Reliability Features

Installation Features

Maintenance Features


Factory-Installed Options

  • Non-fused Disconnect
  • Premium, E-coated condenser coil
  • Convenience outlet (powered)
  • Low ambient temperature Motormaster® control
  • Louvered hail guards

Field-Installed Accessories

  • Low ambient temperature Motormaster® control
  • Louvered hail guard
  • Programmable thermostats

38AUQ/40RUQ AHRI Cooling Ratings

Unit Cooling Stages Nominal Capacity (Tons) Net Cooling Capacity (MBH) Total Power (kW) EER IEER
38AUQ07 / 40RUQ07 1 6 70.0 6.4 11.0 12.6
38AUQ08 / 40RUQ08 1 7.5 89.0 8.1 11.0 12.0
38AUQ12 / 40RUQ12 1 10 112.0 10.2 11.0 12.0
38AUQ16 / 40RUQ16 2 15 178.0 16.8 10.6 11.0
38AUQ25 / 40RUQ25 2 20 220.0 20.8 10.7 11.0

38AUQ/40RUQ AHRI High Heat Ratings at 47°F (8°C)

Unit Heating Stages Nominal Capacity (Tons) Net Cooling Capacity (MBH) Total Power (kW) COP
38AUQ07 / 40RUQ07 1 6 66.0 5.9 3.30
38AUQ08 / 40RUQ08 1 7.5 87.0 7.7 3.30
38AUQ12 / 40RUQ12 1 10 106.0 9.4 3.30
38AUQ16 / 40RUQ16 2 15 178.0 15.3 3.40
38AUQ25 / 40RUQ25 2 20 214.0 17.9 3.50

38AUQ/40RUQ AHRI Low Heat Ratings at 17°F (-8°C)

Unit Heating Stages Nominal Capacity (Tons) Net Cooling Capacity (MBH) Total Power (kW) COP
38AUQ07 / 40RUQ07 1 6 39.0 5.2 2.20
38AUQ08 / 40RUQ08 1 7.5 52.0 6.9 2.20
38AUQ12 / 40RUQ12 1 10 70.0 9.3 2.20
38AUQ16 / 40RUQ16 2 15 108.0 13.2 2.40
38AUQ25 / 40RUQ25 2 20 130.0 15.9 2.40

AHRI = Air-Conditioning, Heating and Refrigeration Institute
ASHRAE = American Society of Heating, Refrigerating and Air Conditioning, Inc.
EER = Energy Efficiency Ratio
IEER = Integrated Energy Efficiency Ratio
COP = Coefficient of Performance

NOTES
1. Rated in accordance with ARI Standard 340/360---07, as appropriate.
2. Ratings are based on:
Cooling Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 35°C (95°F) db outdoor air temp.
IEER Standard: 27°C (80°F) db, 19°C (67°F) wb indoor air temp and 4 various outdoor temperatures.
3. All units comply with ASHRAE 90.1 Energy Standard for minimum EER and IEER requirements.