The Apolarm™C oil leak detector is designed for use at tank yards and other facilities where large amounts of oil are stored, to quickly detect leaks and prevent leaked oil from entering effluent water flows.The Apolarm™C is the leading oil leak detector, with some 30,000 units sold throughout the world.
The CSR-3005 is the culmination of over three decades of improvements and modifications based on practical experience in a wide range of commercial settings. With intrinsically safe explosion-proof certification, the CSR-3005 is suited for use in hazardous locations.
Salient features
Oil-resistant, chemical-resistant, weather-resistant float
Operation unimpaired by rough water surface
No false alarms due to dirt and slime on electrodes
Applicable in Zone 0 hazardous locations
Float constructed of self-extinguishing plastic
No special maintenance required ? only periodic cleaning of float surface
Alarms indicate signaling unit malfunction, cable disconnection, and cable short
Able to detect high-viscosity oils
Optional 50 mm electrodes enable thickness of detectable oil layer to be increased
Sure, accurate oil detection by sensor just 150 mm in diameter.
Efficiency and ease of use in indoor and underground channel drain pits.
System alarm automatically initiated by relay circuit, in the event of power loss at signal converter, cable disconnection, or cable short-circuit.
Specifications
Sensor - Apolarm™CSR-3005
Minimum detectable oil layer thickness | 3 to 5 mm |
---|---|
Detection oils | Crude oil, gasoline, diesel fuel, kerosene, heavy fuel oil, lubricating oil, organic solvents, animal and vegetable fats and oils |
Housing structure | Watertight, IEC Class IP67 equivalent |
Explosion-proof rating | IEC Ex ia IIC intrinsic safety certified |
Operating temperature | -20 to + 60°C (liquid layers must be free from freezing) |
Dimensions | 300 mm diam. X 140 mm H |
Weight | Approx. 2.6 kg (excluding sensor cable) H |
Signal cable(included) | PVC sheathing, two 0.2 mm 2 wires, 12 m length Highly flex-, heat-, and oil-resistant |
Max. cable length | Extension up to 2 km maximum (limit under IIC T4 rating) |
Signal Converter - AS-40
Relay contacts | Form C configuration for both oil detection signal and system malfunction signal; terminals rated 250 V AC, 4 A |
---|---|
Operating temperature | 10 to + 50°C |
Power source | 100-110 V AC or 200-220 V AC, 50 or 60 Hz |
Dimensions (W x H x D) |
80 x 120 x 76 mm |
Weight | Approx. 0.8 kg |
Sensor - MicroApolarm™CSR-1505
Minimum detectable oil layer thickness | 3 to 5 mm |
---|---|
Detection oils | Crude oil, gasoline, diesel fuel, kerosene, heavy fuel oil, lubricating oil, organic solvents, animal and vegetable fats and oils |
Housing structure | Watertight, IEC Class IP67 equivalent |
Housing material | High impact PVC |
Electrode material | SUS 316 |
Operating temperature | -20 to + 60°C (liquid layers must be free from freezing) |
Dimensions | Approx. 150 mm diam. X 60 mm H |
Weight | Approx. 170 g |
Attached cable | 0.2 mm sq. , 2-wire, 12 m |
Max. cable length | 2 km (limit with IIC T4 rating) |
Signal Converter - AS-20
System alarm | Initiated by power loss at signal converter, cable disconnect, or cable short-circuit |
---|---|
Delay timer | Adjustable, approx. 1-10 sec |
Power source | AC100/110V, 200/220V; 50/60 Hz |
Power consumption | Approx. 2VA |
Relay contacts | Form C configuration for both oil detection signal and system malfunction signal |
Terminal rating | AC250V, 4A; DC30V, 4A |
Operating temperature | -10 to + 50°C |
Operating humidity | 95% RH |
Power source | 100-110 V AC or 200-220 V AC, 50 or 60 Hz |
Dimensions (W x H x D) |
80 x 120 x 76 mm |
Weight | Approx. 0.8 kg |
Apolarm™C (CSR-3005)
(1)TC-SE Low-water guard | For applications where water level may become too low for the detector unit to float. The adapter grounds the electrodes to prevent false alarms when water is low. |
---|---|
(2)4A-8 Cable float | Installation of cable float recommended to prevent cable tension or entanglement due to rough water surface. |
(3)CSR-3005 sensor | |
(4)Guide bar | For application in a wide space, with high flow, or with rough water surface. Guide bar prevent the sensor from drifting and tilting. |
(5)Guide bar supports | Install as appropriate when guide bars are used. |
(6)Junction box | Required for attachment of extension cable when the sensor and signal converter are installed more than 12 m apart. |
(7)Extension cable | Install as necessary when the signal converter is more than 12 m from the sensor. |
(8)AS-40 signal converter | |
(9)Signal converter case | Install as necessary to obtain IEC IP66 class ingress protection. |
(10)Power and alarm cable | Install as required for specific applications. |
*All components optional other than sensor and signal converter.