HI97702 is an advanced portable photometer for the measurement of high levels of copper in water. This meter offers a superior optical system that utilizes a reference detector and narrow band interference filters for extremely fast and repeatable measurements.
Due to its malleability, thermal and electrical conductivity, and corrosion resistance, copper is used in a variety of industrial and technological applications. Copper may also be present in natural water and effluents due to widespread use to control biological growths in reservoirs and distribution pipes.The HI96702 uses an adaptation of the USEPA approved bicinchoninate method to measure copper concentrations of less than 5.00 mg/L (ppm). When the reagent is added to samples containing copper, the sample will turn a purple hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complimentary color, and the emitted radiation is dependent upon concentration. For higher levels of copper, a narrow band interference filter at 575 nm (yellow-green) allows only yellow- green light to be emitted and passed through the sample cuvette. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.
This innovative optical system offers superior performance in accuracy, repeatability, and required time to perform a measurement. This compact, waterproof meter has a tutorial mode that walks the user graphically, step by step, to perform a measurement. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use.
CAL Check
Advanced features including CAL-Check to verify performance and if necessary, recalibrate.
Setup Options
Setup options for meter personalization include date and time format, language, and enabling the tutorial mode.
Backlit Display
Backlit dot matrix LCD that offers an exceptionally intuitive user interface that is easy to read and understand.
Tutorial Mode
Tutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.
Stable Light Source:
High Efficiency Light Source:
High Quality Filters:
Greater Light Yield:
A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.
CAL Check Functionality:
Large Cuvette Size:
Intuitive Dot Matrix Display:
Auto-off Protection:
SKU | HI97702-web |
---|---|
Product Name | Copper High-Range Portable Photometer with CAL Check – HI97702 |
Quote Required | Yes |
Copper Range | 0.00 to 5.00 mg/L (as Cu) |
Copper Resolution | 0.01 mg/L |
Copper Accuracy | ±0.02 mg/L ±4 of reading at 25°C |
Copper Method | adaptation of the EPA Method |
Photometer/Colorimeter Light Source | LED with 575 nm bandpass filter |
Photometer/Colorimeter Light Detector | silicon photocell |
Bandpass Filter Bandwidth | 8 nm |
Bandpass Filter Wavelength Accuracy | ±1.0 nm |
Cuvette Type | round 24.6 mm diameter (22 mm inside) |
GLP | yes |
Display | 128 x 64 pixel B/W LCD with backlight |
Logging Memory | 50 readings |
Battery Type/Life | 1.5 V AA Alkaline (3 pcs.) / > 800 measurements (without backlight) |
Automatic Shut-Off | after 15 minutes of inactivity (30 minutes before a READ measurement) |
Environment | 0 to 50°C (32 to 122°F); 0 to 100% RH (IP67) |
Weight | 380 g (13.4 oz.) |
Dimensions | 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0'') |
Ordering Information | HI97702C is supplied with CAL Check standards, cuvettes (2), caps (2), plastic inserts for cuvette, (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate packaged in a rugged, thermoformed, carrying case. |