Mô tả
F735 is an indicator that converts and displays signals from load cells into digital values. Equipped with CC-Link Ver.2.00 as standard, it can communicate as a Ver.2 remote device station.
Operation mode can be set as high speed (300 times/sec), medium speed (100 time/sec) or low speed (30 times/sec). A wide range of necessary uses are supported from high speed response to high stability. Resistant to vibration, and even troublesome filter setting can be done with simple operation with one button.
Front panel part is dust & waterproof by installing the attached packing. It is a practical device equipped with abundant functions that focus on “measurement” such as 5-point calibration,
dual range, high resolution & comaprison function, conformity to Measurement Act and more.
Small size, lightweight & compact design thus easy-to-mount
Especially the depth from its front panel is only 99mm when it is panel-mounted. (The depth is 120mm when including the protruding part)
CC-Link is equipped as standard
F735 can communicate as a remote device station for CC-Link Ver.2.
As characteristics of Ver.2, by using double extended cyclic setting, the same memory allocation for occupying 2 stations can be used while occupying 1 station.
Thus, the maximum number of the unit that can connect with the master compatible with Ver.2 is 42.
In addition, it can communicate with the master even if the master is CC-Link Ver.1 such as for replacement of conventional system.
(However, it will be a network communication as Ver.1 in this case.)
Easy filter value adjustment
Anyone can adjust filter value that suits situations at sites.
Various correction function also supported
Also supporting equivalent calibration, linearization calibration, dual range function and more.
Sampling rate changeable
According to applications, the sampling rate can be changed by user.
In case high speed response is required such as for automated instruments and checkers, select 300 times/sec. In case measurement with invariable stability is required such as for non-automatic measuring instrument, select 100 times/sec or 30 times/sec.
Dust & waterproof at front part
The front part is dust & waterproof by installing the attached packing and panel-mounted.
Selectable power source & language
DC power (24V) and English specification are available. (Please specify when ordering)
Specified measuring instrument
F735 is an indicator module (Accuracy class: class 3, scale interval: 6000) for type approval of “for transaction and certification” that is defined by Level H of JIS B 7611-2.
*Only with AC specs.
Analog section |
Excitation voltage |
DC5V±5% Output current:within 90mA
Ratio metric type (Up to six 350Ω load cells can be connected in parallel.) |
Signal input range |
-0.3 to 3.0mV/V,
0 to 3.0mV/V (When supporting JIS B 7611-2) |
Zero adjustment range |
Automatic adjustment by digital operation
0 to 2.0mV/V |
Gain adjustment range |
Automatic adjustment by digital operation
0.3~3.0mV/V,
0/6~3.0mV/V(When supporting JIS B 7611-2) |
Gain correction |
Up to 3 point multi-point calibration is
possible using linearization function |
Minimum input sensitivity |
0.15μV/count
0.5μV/count (When supporting JIS B 7611-2) |
Accuracy |
Non-linearity: within 0.01%/FS
Zero drift: 0.025μV/℃ RTI typ
Gain drift: 1ppm/℃ typ |
Low pass filter |
High speed (300 times/sec):1.5Hz,2Hz,2.5Hz,3Hz,4Hz,5Hz
Midium speed (100 times/sec):0.5Hz,0.67Hz,0.83Hz,1Hz,1.33Hz,1.67Hz
Low speed (30 times/sec):0.15Hz,0.2Hz,0.25Hz,0.3Hz,0.4Hz,0.5Hz |
Moving average filter |
Selectable within the range of 2 to 512 times |
A/D converter |
Conversion rate: 300 times/sec.
Conversion resolution: 24bit (binary)
Enabled resolution: More than 400000 (for -0.3 to 3.0mV) |
Minimum indication resolution |
1/10000, 1/6000 (When supporting JIS B 7611-2) |
Secondary calibration |
Equivalent input calibration Minimum indication resolution for secondary calibration:1/1000 (ordinary temperature) |
Display section |
Display |
Character height 14mm
Number display by 7-segment green LEDs (6 digits) |
Indicated value |
5 digit sign: negative display at the highest digit |
Display frequency |
Select from 3, 6, 13, 25times/sec.(The system speed is 300 times/sec.) |
Capacity |
5 digit |
Min. scale division |
Setting allowable in the range of 1 to 50. |
Decimal point |
Select from 0, 0.0, 0.00, 0.000 |
Over display |
LOAD: A/D converter input over
OFL1: Net over
OFL2: Capacity +9 scale division
-OFL2: Capacity -over or -20 scale division over
OFL3: Gross over |
Center zero |
A true zero point or the center of each value is displayed. |
Status display |
HI/GO/LO/NZ/HOLD/ZALM/STAB/TARE/NET/CZ
(9 x red LEDs、1 x green LED) |
Setting section |
Setting method |
Settings are made by operating the membrane keys.
Also, setting from the master unit via CC-Link I/F is available |
Memory of set value |
Memory using F.RAM (non-volatility RAM) |
Protect of set value |
Protection is possible using a LOCK switch. |
Setting items |
Upper limit / Lower limit / Near zero / Function selection 1 / Auto hold ime / Preset tare setting / Tare display
Net over / Gross over / Key invalid・LOCK / Password / Measurement Act correspond setting
Digital low pass filter / Moving average filter / Operating mode / Motion detection (period-range) / Zero tracking (period) / Function selection 2 / Function selection 3 / Display selection
Balance weight value / Capacity / Min. scale division / DZ regulation value / Dual range boundary / Gravitational acceleration / Equivalent calibration / Zero calibration / Span calibration
CC-Link baud rate / CC-Link station number / CC-Link occupied station / SI/F setting
Linearization calibration 1 / Linearization calibration 2 / Linearization calibration 3 / Span correction / Linearization calibration / Calibration point display / Zero calibration / Span calibration
Digital low pass filter / Moving average filter / Operating mode / Version display / Checksum display
|
Interface |
SIF |
2-wire serial interface |
CCL |
CCL-Link Interface |
General performance |
Power supply voltage |
AC spec. :100 to 240V AC (+10% -15%) (Free power supply 50/60 Hz)
DC spec. :DC24V(±15%)(DC power supply should be specified at shipping) |
Power consumption |
4W typ. |
Operating conditions |
Temperature: Working temperature range -10 to +40°C;
Storage temperature range -20 to +60°C
Humidity: 80% RH or less (non-condensing) |
Dimensions |
144(W)×72(H)×99(D) mm (protruding parts not included) |
Weight |
Approx. 800g |
Attachments |
AC input cord (Nominal rating 125V) 3m |
1 |
CC-Link connector |
1 |
Mini Driver |
1 |
Packing |
1 |
Unit label |
1 |
Operation manual |
1 |
iMS Motion Solution (Johor) Sdn Bhd (Company Registration 1098771-W)
No.7, Jalan Sasa 4,Taman Gaya, 81800 Ulu Tiram, Johor Bahru, Johor. Malaysia.
TEL:+607-8635240 FAX: +607-8637240
MOBILE: +6019-6774477
HOTLINE : 1700-818-330
whatsapp us now !
Brand Name
| MEISTER | GGM | Sanyo Denki | ElectroCraft | EDrive | SHIHLIN ELECTRIC | AUTONICS | UI Robot | Mitsubishi CNC | PANASONIC| Apex Dynamics | NISSEI GTR | UNIPULSE | CREVIS
| MOTION DEVICES SPECIALIST | SYSTEM and CONTROL INTEGRATION |
| Induction Motor | Speed Control Motor | Reversible Motor |Brake Motor |BLDC Motor |DC Motor |Planetary Gear Motor | Servo Motor | Stepping Motor | Linear Actuator Motor | Lead Screw Motor|Close Loop Stepping Motor | Customization Motors | Right Angle Gear Head | Precision Gear Reducer |PLC | Motion Controller |HMI /Touch Screen| Inverter |CNC Controller |Multi Axis Robots |IPC | SCADA |Monitoring Software | Embeded PC | Remote IO |TPC | Motion Card | Loadcell |PPC |
Return / Refund Policy :
All goods sold are not returnable & we accept goods ex-change with equal or lower value of good purchased. If the ex-change items are higher than purchased items, buyer shall top up the differential cost. All payment made are not refundable, please confirm the purchase items code & cost with our sales representative before place orders.
Shipping and Fulfillment :
Thank you for your purchase. Once we have confirmed your payment, we will prepare and ship out your order out within 24-48 hours.( For ex-stock items only, Indent items subject to delivery stated in quotation & conversation in emails). Once your order has been shipped out, you will receive an email notification with the tracking number and tracking details inside.
Private Policy
General Statement of Principles
As described in detail below, any information we gather at this web site is strictly for our use and is not shared with any other entity, public or private, for any reason - period. We will not sell or give away any lists or other data that we may retain and we do not purchase such information from other sources.
Statistical Data
Our servers (as most) track IP addresses and referring pages to help with site maintenance and improvements. This data is viewed only as anonymous statistics to show the busiest times of the day or week, pages with errors and how effective our advertising has been. This information is not used for any other purpose.
Personal Information Collected - Order Forms
With the exception of credit card info, we store the information from your order form to allow us to track consulting issues or refer to a previous order to help provide some customer service. You may elect to have your information completely removed from this system by e-mailing us at [email protected] with your request. We do not store any type of sales information.
Information Correction or Removal
If you wish to correct, update or remove any information about you that may be in our records, please send us e-mail at [email protected] with the details of your request. If you wish to contact us further, please find complete contact information on our contact page.
Cookies
Cookies are files with small amount of data, which may include an anonymous unique identifier. Cookies are sent to your browser from a web site and stored on your computer's hard drive. We use 'cookies' to store your cart contents for you. You can instruct your browser to refuse all cookies or to indicate when a cookie is being sent. However, if you do not accept cookies, you may not be able to use the checkout section of our site.
Changes To This Privacy Policy
This Privacy Policy is effective as of 1st Jan 2019 and will remain in effect except with respect to any changes in its provisions in the future, which will be in effect immediately after being posted on this page.
Xem thêm chi tiết về IMS Mechatronics Sdn Bhd