Mô tả
Yokogawa IS8000 Integrated Software Platform
-
IS8000 test and measurement software that integrates data
-
Fast data for efficient product development
-
Synchronized measurements
-
Add-on software packages
-
Brochures
The IS8000 Integrated Software Platform streamlines the process of integrating, synchronizing, and measuring data. Add-on software packages give this test and measurement software evolving capabilities.
-
*The firmware update is required for each devices to connect IS8000.
DL950:Ver.1.20 or later, WT5000:Ver. 3.31 or later
Ver. 23.1.1.0
-
New IEC61000 standard (3-3 Ed3.0-amd2) is supported in IS8011/IS8012.
-
''DAQ(WT)'', which displays a layout suitable for online DAQ of WT5000, is added to the launcher window.
Ver. 22.6.1.0
-
Added new API function: any waveform file access
-
Improved the performance of analysis functions
-
Enabled importing CSV files saved with DL950, DL850 series, DL350, DLM5000/4000/3000/2000 series, Xviewer Application Software and IS8000 (version 22.6.1.0 or later)
-
Enabled importing/exporting CSZ format (CSV data compressed in ZIP format)
Ver. 22.5.1.0
-
Added new API functions
-
Improved the performance of analysis functions
-
Enabled CSV exports of dual-caputured sub-channel data, FFT analysis data, and sequential historical data
-
Added support for a vector diagram display for off-line analysis functions
-
Added support for the latest IEC standard, IEC61000 3-2 Ed5.0-amd1, with IS8011/IS8012
-
Added support for Windows11 with IS8011/IS8012
(All IS8000 series functions except EM1 option are Windows 11 compliant)
-
FS1 option: The information on camera models that support real-time synchronization has been changed
-
MATLAB Runtime support: By installing MATLAB Runtime, up to 100M of FFT points can be supported
Ver. 22.4.1.0
-
Added support for Windows11 (except IS8011 and IS8012)
-
Added a new API function
-
Improved the performance of analysis functions
-
Added support for the DAQ (data acquisition) function from DL950 with an external clock
-
Added support for a vector diagram display for WT5000’s online monitoring and DAQ function (supporting one for offline analysis functions will be available in a future update)
-
Removed the limitations of the maximum DAQ period which were seven days and 500 GB
-
Added support for the offline synchronization function with two video files and waveforms (FS1 option required)
-
Added support selecting “seconds” and “points” for the time axis information of saved data in the CSV export function
Ver. 22.3.1.0
-
Added the new API functions (IS8000 control API)
-
Improved performance for offline analysis
Ver. 22.2.2.0
-
Supported the IS8000 API (Application Programming Interface)
Ver. 22.2.1.0
-
Supported WT5000 data streaming (/DS) function *1
This function streams the waveform data measured by the WT5000 continuously to the PC.
In addition, the measured waveform can be saved as an MDF/CSV file, analyzed for feature points, calculated, and FFT processed *2.
More detailed analysis is possible, such as how a change in the noise or control state affect the power value and each parameter.
*1 DS option is required on the connected WT5000.
*2 MH1 option on the IS8000 is required for some calculations and analysis
-
Added the customization of the default window layout
The initial window layout can be customized freely. This is useful when you want to fix the display layout.
-
Increased the number of harmonic bar graphs displayed from two to six.
Ver. 22.1
-
Video File Offline Synchronization (/FS1 option)
It is possible to display video data other than supported high-speed cameras by offline analysis.
*Supported file format
AVI(*.avi)、MP4(*.mp4)、WMV(*.wmv)
AVCHD(*.mts)、MOV(*.mov)、MPEG2-PS(*.mpg, *.mpeg)
-
Screen Capture function added
The function which save IS8000 display added. It is possible to narrow down the target such as Zoom waveform and save it.
-
Supports mouse wheel operation for waveform display
It is possible to operate such as moving the vertical scroll bar with the mouse wheel.
-
Added CSV file batch converter function
It is possible to convert multiple waveform files to CSV at once.
-
Added Probe setting
The attenuation ratio of the probe that can be set has increased.
-
The result of power calculation (/ G5) is added to the target of DL950 Flash ACQ data saving.
Supports MDF file saving of DL950 power calculation result in Flash ACQ data saving.
Ver. 1.4
-
Added Channel Mapping Function
Channel Mapping function was added to “Channel Setting”.
This function allows you to change the display channel assignments.
-
Supported the Real-time Power Math Function of DL950
The online data acquisition of results for the real-time power math computation of DL950 (/G05) is supported on latest IS8000.
-
Updated CSV file export function
Exporting multiple waveform data with different sampling interval to a single CSV file has been supported. It also supported CSV file exporting function of numeric, matrix and harmonic bar graph data.
-
Added Apply button to channel setting window of offline analysis
The channel setting changes can be reflected in the waveform window without closing the channel setting window.
Ver. 1.3
-
Supported DL950 Flash acquisition function (/ST2)
Acquisition data of DL950 flash acquisition function can be imported to IS8000.
-
Supported WT5000 10ms update rate
Update rate of WT5000 can be set to 10ms when connecting IS8000.
-
Supported matrix display of WT5000 numeric data
Latest IS8000 can display the matrix of WT5000 numeric data in offline analysis.
-
Supported WVF file
Supports reading WVF file created by DL750 or SL1400.
(The HDR file with the same name as the WVF file is required.)
-
Added CSV export function on the simple version
It is possible to export measurement data to CSV file on the simple version.
-
The Power of One
The IS8000 software platform is an integrated solution that accelerates engineering workflow. It is a revolutionary software solution that tightly integrates the timing, control, and data collection from multiple instruments, creating a comprehensive measurement suite that delivers high confidence, efficiency, and unity.
High speed data acquisition up to 10 Gb
In combination with the 10 GbE option (C60 option) on the DL950 and the IS8000, up to 8 channels of data can be stored in real time on a PC at a sampling rate of up to 20 M samples per seconds.*
Longer recording times are now possible for high-speed, multi-channel inputs such as gate signals and switching waveforms of multi-phase inverters.
* With 1 Gb Ethernet/USB connection, the maximum transfer rate is 6.4 MB/s (200 kS/s × 16 ch)
Multi-unit monitoring with time synchronization (SY1 option)
IS8000 and SY1 option enable accurate power and waveform data synchronization across multiple channels with minimal error. Data from the WT5000 power analyzer and DL950 ScopeCorder is time correlated with less than 10 us error using IEEE1588 technology.
Control and realtime remote monitoring
YOKOGAWA’s high-precision power analyzer, ScopeCorder and oscilloscope can be remotely operated, monitored and configured from IS8000. Additional options, third-party high-speed cameras can also be controlled, greatly reducing the burden of operating and managing various instruments measuring power, physical phenomenon, video, and control signals.
FFT and math function (MH1 option)
Measure up to 16 FFT processes for a wealth of analysis functions for automatic calculation of frequency and integrated value and filter processing.
Report generator (RP1 option)
Customized reports are easily created by dragging and dropping measurement data, waveforms, graphs, etc. onto the sheet.
File import and export
The IS8000 supports binary, ASCII, and the MDF format, a very common format for the automotive industry. Power and waveform data on the IS8000 can be shared with your development system or third-party software.
*1 Import of MDF files generated by other software/devices will be supported in the future
*2 Power trend data saved by WT5000, WT3000, 1800 series
Synchronization high-speed camera (FS1 option)
IS8000 synchronizes high speed camera images with related current, voltage, and control signals. Simultaneous slow motion playback allows visualization between design and results.
In addition, video files captured by other than high-speed camera and waveform files can be synchronized offline for display and analysis.
Optional software package for IEC harmonic and flicker compliance test
IS8011/IS8012 optional software package is designed to perform harmonic and flicker tests in accordance with IEC61000-3-2, 3-3, 3-11 and 3-12 standards using the WT5000 precision power analyzer. Users can easily set the conditions and output the test report without any specialized knowledge. Users can make a pass/fail judgment by class A, B, C, and D of the harmonic current measurement values.
Compatible measurement device:
WT5000 (/G7 option required)
Applicable standards:
IEC 61000-3-2 Harmonic Measurement
-
IEC 61000-3-2 Edition 3.0:2005/A1:2008/A2:2009, IEC 61000-3-2 Edition 4.0:2014, IEC 61000-3-2 Edition 5.0:2018/A1:2020
-
EN 61000-3-2:2006/A1:2009/A2:2009, EN 61000-3-2:2014, EN 61000-3-2:2019, EN 61000-3-2:2021
-
IEC 61000-4-7 Edition 1.0:1991, Edition 2.0:2002 and A1 of the Edition 2.0:2008
-
EN 61000-4-7:1993, EN 61000-4-7:2002/A1:2009
-
JIS C 61000-3-2:2011, JIS C 61000-3-2:2019
-
JIS C 61000-4-7:2007
IEC 61000-3-3 Voltage Fluctuation and Flicker Measurement
Voltage fluctuation and flicker suppression standards
-
IEC 61000-3-3 Edition 2.0:2008, IEC 61000-3-3 Edition 3.0:2013/A1:2017/A2:2021
-
EN 61000-3-3:2008, EN 61000-3-3:2013, EN 61000-3-3:2013/A1:2019, EN 61000-3-3:2013/A2:2021
Flicker meter function and design specifications
-
IEC 61000-4-15 Edition 1.1:2003, IEC 61000-4-15 Edition 2.0:2010
-
EN 61000-4-15:1998/A1:2003, EN 61000-4-15:2011
IEC 61000-3-11 Voltage Fluctuation and Flicker Measurement
Voltage fluctuation and flicker suppression standards
-
IEC 61000-3-11 Edition 1.0:2000, IEC 61000-3-11 Edition 2.0:2017
-
EN 61000-3-11:2000, EN 61000-3-11:2019
Flicker meter function and design specifications
-
IEC 61000-4-15 Edition 1.1:2003, IEC 61000-4-15 Edition 2.0:2010
-
EN 61000-4-15:1998/A1:2003, EN 61000-4-15:2011
IEC 61000-3-12 Harmonic Measurement
-
IEC 61000-3-12 Edition 1.0:2004, and Edition 2.0:2011
-
EN 61000-3-12:2005, EN 61000-3-12:2011
-
IEC 61000-4-7 Edition 2.0:2002/A1:2008
-
EN 61000-4-7:1993, EN 61000-4-7:2002/A1:2009
IEEE1588 Precision Time Protocol
IEEE 1588 is a standard for the Precision Time Protocol (PTP), a protocol for high-precision time synchronization of networked instruments and control systems. The PTP grandmaster server provides a reference clock for each client instrument to achieve high-precision clock synchronization. Since the ScopeCorder DL950 has the PTP master function, high precision clock synchronization of the corresponding instruments on the same network is possible even without a PTP grandmaster server. The IS8000 is also capable of combining the simultaneous measurement data of each of these PTP-synchronized instruments in the same window.
-
-
Automotive & Industrial
Motor Efficiency
Overview
Motor efficiency is a critical measurements for electric vehicles as small improvements can result in increased range. Efficiency measurements require accurate synchronous measurments of power consumption with motor speed and torque.
IS8000 Advantage
High Precision synchronized power and high speed recorder measurements
Data from the WT5000 power analyzer and DL950 ScopeCorder is time correlated with less than 10 us error using IEEE1588 PTP technology. Precise power parameters and waveforms are displayed on the same time axis.
Switching Waveform Analysis for SiC Invertor
Overview
In order to analyze the motor and inverter system, voltage and current signals between 3 phases, motor I/O signals, and multiple IGBT gate signals are required to properly measure and diagnose system performance and efficiency.
IS8000 Advantage
Combining multiple waveforms
More than 8 waveforms are required to measure invertor performance in a loaded system. IS8000 can connect with multiple 8 channel DLM5000 oscilloscopes for analog and digital signals to scale up to any channel requirement, all in one control and viewing interface.
Power & Energy
Solar/Wind Power System Development
Overview
Renewable energy systems, like wind, solar and hydro must maintain efficiencies through their power conversion stages to decrease their impact on the environment. Multiple measurement points require precsion and synchronization.
IS8000 Advantage
View and compare waveforms from multiple instruments
IS8000 can easily shnchronize waveforms from multiple instruments, creating an easy view for comparion. Manipulating waveforms is easily done with zoom and pan controls to analyze long records of energy waveforms.
Research & Development
Analysis of Robotic Welding Control
Overview
It is necessary to optimize robotic welding conditions for a cost effective manufacturing system. Multiple signals and inputs are required to be monitored in order to determine the best combination between the robot’s position and performance, including high speed camera inputs, source voltage and current, and multiple position and control I/O signals.
IS8000 Advantage
Simultaneous recording of multiple signal types
IS8000 displays multiple inputs. The camera image is aligned in time with the other waveform, including the control signals and the voltage and current waveforms. Simultaneous slow motion playback allows visualization between design and results.
IS8000 Edition, License and Features
Subscription License
This licenses type is based on annual subscription renewal for the platform and optional features. Users can purchase the software for as long as they need it, keeping their initial investment to a minimum. Users will always have the latest version of the software available for the duration of the subscription, so they will always be able to use the latest features, standards and security.
Perpetual License
This is a one-time purchase and can be used indefintely. Additional optional features can be purchased at a later date. The platform can be upgraded free of charge for up to five years major software version revisions after purchase. After that, users can continue to use the software in the same environment. This license is suitable for users who do not plan to change their equipment environment at the time of installation.
Activation
All IS8000 models and licenses, except the free trial period, require software activation over the internet before use. If the PC with the IS8000 installed cannot be connected to the network, it is possible to activate the IS8000 via another network-accessible PC. For more information, please refer to the electronic manual.
-
DL950 ScopeCorder
The DL950 combines a mixed signal oscilloscope and portable data acquisition recorder into a single platform which can capture both high speed transient events and long term trends and capable of high-speed, multi-channel measurements up to 200 MS/s and up to 16-bit A/D. With a combination of more than 20 different modules for your application, a single unit can measure isolated analog signals from low voltage to 1000 V, as well as logic signals, vibration and strain, temperature and more. It can also display automotive communication data such as CAN/CAN FD/LIN/ SENT as trend waveforms. The 12.1-inch large touch screen enables an intuitive operation. The newly designed application menu makes it easy to set up frequently-used applications. By combining the DL950 with the IS8000, data can be transmitted directly to a PC while measuring, allowing analysis on a PC. Up to five DL950 units can be synchronized with optical fiber cords to measure up to 160 channels simultaneously. Click here to learn more about the DL950 ScopeCorder.
WT5000 Precision Power Analyzer
WT5000 precision power analyzer is a high-precision power meter with a basic power accuracy of ±0.03%, one of the best in the world. With a DC power accuracy of ±0.07%, a 10 MHz voltage measurement bandwidth, a 5 MHz current measurement bandwidth, and a low power factor characteristic of ±0.02% (of apparent power), the WT5000 provides highly accurate measurements of power consumption, loss, and conversion efficiency of devices. Up to seven power inputs and four motor torque inputs enables simultaneous evaluation of multiple motor drive systems. The WT5000 helps to improve the efficiency of development of EVs, EHVs, renewable energy related devices, and energy saving home appliances. Click here to learn more about the WT5000 Precision Power Analyzer.
DLM5000 Oscilloscope
The DLM5000 is a mixed-signal oscilloscope with 8 analog channels and 32 bits of logic input on each unit. It is available in two frequency bands, 500 MHz and 350 MHz. The DLM5000 combines fast sampling rates of up to 2.5 GS/s and a long memory of up to 500 Mpts, making it ideal for a wide range of waveform measurements. A wide variety of triggers, serial bus analysis functions, arithmetic functions and our original “History” functions provide powerful support for waveform measurement operations. Click here to learn more about the DLM5000 Oscilloscope.
Compatible Models
Standard Functions
*1 Only one unit
*2 Limited functions
Optional Functions
Compatible high-speed cameras for online synchronization:
Photron FASTCAM SA-Z、MIni UX*/AX/WX series, NOVA S series, NOVA R2
* Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.
-
Xem thêm chi tiết về Hexo Industries (M) Sdn Bhd