Yokogawa WT500 Mid-Range Power Analyzer

Yokogawa WT500 Mid-Range Power Analyzer

Danh mục: Yokogawa Có sẵn
Để biết thêm thông tin, truy cập trang web chính thức của chúng tôi tại hexoind.com

Mô tả

Yokogawa WT500 Mid-Range Power Analyzer


The WT500 Power Analyzer excels at single- and three-phase power measurements. Standard features include a color TFT display and USB interface for communications and memory. The instrument has a basic power accuracy of 0.1%, maximum inputs of 1000 V, 40 A and a measurement bandwidth of DC to 100 kHz.


Brochures
-

Highlights

Current range: 0.5 to 40 A
Voltage range: 15 to 1000 V
Basic Power Accuracy: 0.1%
frequency range: DC 0.5 Hz to 100 kHz

Key layout offers intuitive control

  1. Cursor Keys
    Cursor keys can be used to move the on-screen cursor in four different directions. The cursor keys and SET key can also be used for making selections in soft menus. The WT500's menu structure is even more user-friendly than other models.
  2. RANGE Keys
    The RANGE keys can be used to set the voltage and current ranges. Quick intuitive range control is available by using direct keys.
  3. DISPLAY Keys
    DISPLAY keys can be used to switch between numerical values, waveforms, and other displays. The display format can easily be changed.
  4. SETUP Key
    The SETUP key can be used to enter various settings required for power measurement such as the wiring method and filters.
  5. FILE, IMAGE, and STORE Keys
    The keys related to data storage are located in the same area. Data can be easily stored to USB memory.
Tm Wt500 02
 



















Features

Newly Designed Architecture

Tm Wt500 03

Intuitive control by using cursor keys in four different directions.
To reduce setting errors, menus display settings in order of relative importance in order.

Measured Value Direct Save Function

Tm Wt500 04

Two USB ports for peripherals are installed for direct data saving (up to 1 G byte) in USB memory at shortest intervals.
The saved data can be opened in applications such as Excel.

* Excel is a registered trademark of Microsoft Corporation in the U.S.A.

A Variety of Display Formats

Tm Wt500 05

In addition to numerical data, the WT500 can display input signal waveforms and trends (time variation of numerical data).
Bar graph display and vector display are also available with the harmonic measurement (/G5) option.

*1 Waveforms of up to approximately 5 kHz can be displayed.
*2 Excludes single-phase models.
Split screen display for numerical values and waveforms is not available.

Simple Setting and Display of Efficiency

Two efficiency calculations can be set by selecting input elements or output elements from a list.

Example: η1 = PΣ/P1 x 100%
η2 = PΣ/P2 x 100%

USB Memory Storage Function

Only necessary items within the measured data like voltage, current, and power can be saved in USB memory in binary or CSV format (up to 1 GB).

Files saved in CSV format can be opened in general-purpose applications such as Excel to allow displaying of data in graphs.

Tm Wt500 06







Variety of Integration Functions

In addition to integration functions of active power (WP), current (q), reactive power (WQ), and apparent power (WS), a new feature provides measurement of bought and sold watt hours. Also, average active power can be calculated over an integration interval.
This feature is useful for evaluating the power consumed by intermittent-control instruments in which the power value fluctuates. Average active power is calculated by using user-defined settings.

Tm Wt500 07









GP-IB Communication (/C1)

GP-IB communication enables you to control the WT500 or transfer data from a PC.

Ethernet Communication (/C7)

Data can be transferred via Ethernet* communication.
It enables file transfers using an FTP server.

* 100BASE-TX

Tm Wt500 17






External Current Sensor Input (/EX1, /EX2, /EX3)

Current can be measured by using current clamps without disconnecting power supply wiring (voltage output type). By setting an external current sensor conversion ratio, it can support various types of current clamp-on probes.

VGA Output (/V1)

By connecting to a monitor, you can create large displays of numerical values and waveforms. This function is convenient for simultaneously confirming data on multiple monitors, or to check data remotely.

Harmonic Measurement (/G5)

This function enables simultaneous measurement of normal and harmonic data. Harmonic components of up to the 50th order can be measured. With the WT500 you can simultaneously confirm voltage, current, and the distortion factor (THD) as well as measure the distortion factor without switching modes.

Tm Wt500 18   Tm Wt500 19
Harmonic Dual List   THD measurement

Delta Computation (/DT)

This function allows you to calculate individual phase voltages and phase currents from the line voltages and phase currents measured in a three-phase, three-wire (3P3W) system. The phase voltage can be calculated from the line voltage measured with the three-phase, three-wire (3V3A) method. This is useful when you want to determine the phase voltage in a DUT with no neutral line by using the three-phase, three-wire (3V3A) method.

Note: This function cannot be installed on products with only one element.

Added Frequency Measurement (/FQ)

In addition to the standard two channels of frequency measurement, an option is available for frequency measurement on all channels. This option provides frequency measurement of voltage and current on all channels with input elements 1 through 3 installed.This is necessary when you want to measure voltage and current frequency from the instrument's I/O as well as voltage and current frequencies of multiple items under test at the same time.

Note: This function cannot be installed on products with only one input element.

Rear Panel

Tm Wt500 20

Standard features

  1. Voltage input terminals
  2. Current input terminals
  3. USB communication interface
  4. External trigger Signal, External clock input Connector

Optional features

  1. External Current Sensor Input Terminals (/EX option)
  2. GP-IB communication Interface (/C1 option)
  3. Ethernet Port (/C7 option)
  4. VGA Output (/V1 option)

Characteristics

Example of basic characteristics showing the WT500's high precision

Tm Wt500 21

Tm Wt500 22

Tm Wt500 22

Tm Wt500 23

 

Connection Diagram

Connection for the Measurement Cables and Adapters

tm Wt500 28 1 1

 
Product Part no. Specifications Order quantity
Output connector B8200JQ D-SUB 9-pin, with 2 screws 1
Load resistors B8200JR   10 Ω, 0.25 W x 4
Connect 4 in parallel to set resistance to 2.5 Ω.   
1

Connection Diagram for Clamp-on Probe

Tm Wt500 30 1 1

*Don't connect and use the current input terminal and EXT terminal simultaneously.

-

Accessories

B9284LK External Sensor Cable thumbnail

B9284LK External Sensor Cable

For connection the external input of the WT3000 to the current sensor.
Length: 50cm

CT60/ CT200/ CT1000/ CT1000A/ CT2000A AC/DC Current Sensor thumbnail

CT60/ CT200/ CT1000/ CT1000A/ CT2000A AC/DC Current Sensor

AC/DC current sensors capable of highly accurate measurement starting in DC range.

751512 Banana (Male) to Binding Post Adapter thumbnail

751512 Banana (Male) to Binding Post Adapter

Safety-terminal-binding-post adapter. Use for circuits having voltage levels no greater than 42 V.

758917 DMM Measurement Lead Set thumbnail

758917 DMM Measurement Lead Set

  • Set of 0.8m long red and black multimeter test leads
  • Used in combination with a pair of optional 758922 or 758929 alligator-clip adapters
  • 1000 Vrms, 32 Arms CAT II
758921 Fork terminal adapter thumbnail

758921 Fork terminal adapter

  • 758921 Fork Terminal Adapters
  • For fitting a 4mm banana plug to a fork terminal
  • One black and one red clip
  • 1000 Vrms-CAT II
96001/751552 Current Clamp-On Probe thumbnail

96001/751552 Current Clamp-On Probe

Special AC-Input Clamp-on Probes for Large-current Hot Line Measurement

758922 Small Alligator-Clip Adapter 300V thumbnail

758922 Small Alligator-Clip Adapter 300V

Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.

758923 Spring Hold Safety Terminal Adapter Set thumbnail

758923 Spring Hold Safety Terminal Adapter Set

Two adapters in a set (spring-hold type).

758924 BNC to Banana Conversion Adapter thumbnail

758924 BNC to Banana Conversion Adapter

For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.

758929 Large Alligator Clip Adapter 1000V thumbnail

758929 Large Alligator Clip Adapter 1000V

  • Yokogawa 758929 Alligator Clip Adapter 
  • Rated at 1000V
  • Attaches to 758917 test leads
  • Sold in pairs black/red
758931 Screw-Fastened Safety Voltage Terminal Adapter Set thumbnail

758931 Screw-Fastened Safety Voltage Terminal Adapter Set

Screw-fastened adapters. Two adapters in a set. 1.5 mm Allen Wrench.

751533-E4 Rack mounting kit thumbnail

751533-E4 Rack mounting kit

RACK MOUNTING KIT For an EIA-compliant Single-housing Rack

751533-J4 Rack mounting kit thumbnail

751533-J4 Rack mounting kit

RACK MOUNTING KIT For an JIS-compliant Single-housing Rack

751534-E4 Rack mounting kit thumbnail

751534-E4 Rack mounting kit

RACK MOUNTING KIT For an EIA-compliant Dual-housing Rack

751534-J4 Rack mounting kit thumbnail

751534-J4 Rack mounting kit

RACK MOUNTING KIT For an JIS-compliant Dual-housing Rack

-

Xem thêm chi tiết về Hexo Industries (M) Sdn Bhd
Hexo Industries (M) Sdn Bhd
Hexo Industries (M) Sdn Bhd Measuring Instruments Supplier Malaysia, Leak Detection Systems Supply Penang, Power Tools Supplies Singapore, Indonesia ~ Hexo Industries (M) Sdn Bhd