BENEFIT
Permanent Static Dissipative
Insensitive to environment
Special design for cleanroom application
APPLICATION
To wrap cable or wire inside cleanroom
To coil pen inside cleanroom
Other
SPECIFITION
| 
			 Decay time at end of tube  | 
			
			 0.8 to 1.3 seconds  | 
		
| 
			 Decay time at centre of tube  | 
			
			 0.5 to 1.2 seconds  | 
		
| 
			 Float voltage observed  | 
			
			 0V to 3V  | 
		
| 
			 Peel Off Voltage Observed  | 
			
			 8 * 10 to the power of 8  | 
		
PROCEDURE
OUTGASSING – Three samples of Spiral Coil were used and placed in an outgassing vessel at 85 Degree C. It was then flushed continually for three hours at 50ml/min with grade 5 nitrogen. A carbotrap ‘B’ / carbotrap ‘C’ tube were then used to trap the outgassing constituents after which analyzing using GC/MS with ATD.
 
FTIR / SILICONE OIL / HYDROCARBONS – The presence of silicone oil and hydrocarbons were extracted in solvent soluble residue from one piece of 15.5 “ of ESD Bluish Spiral Coil. Both the inner and outer surfaces, a total of 121cm square, were rinsed with 10ml of hexane and isopropanol by mixing a portion of 1 : 1 (v/v) of the solvent solution. A clean 30ml glass beaker was used to collect the rinsate. The solvent solution was evaporated to dryness. Thereafter, FTIR / HATR was used to analyze for the presence of silicone oil and hydrocarbons on any residue rinsed from the sample.
 
IONIC CONTAMINATION – A ESD Bluish Spiral Coil sample were divided into three sections to test for ionic contamination. Three pre-clean glass beaker containing 10ml of de-ionized water was given one section of the spiral coil sample each and then capped off to prevent evaporation. The glass beakers were then placed in an 80 Degree C oven. The water extract was then analyzed using ion chromatography. A hand measured apparent surface area of 10.2cm square was used to calculate the results.
RESULTS
Below are the data obtained from using the following chemical
| 
			 COMPOUND  | 
			
			 Section 1 Sample  | 
			
			 Section 2 Sample  | 
			
			 Section 3 Sample  | 
			
			 Average  | 
		
| 
			 BHT  | 
			
			 12 ug/g  | 
			
			 12 ug/g  | 
			
			 13 ug/g  | 
			
			 12 ug/g  | 
		
| 
			 KETONES  | 
			
			 28 ug/g  | 
			
			 28 ug/g  | 
			
			 21 ug/g  | 
			
			 26 ug/g  | 
		
| 
			 SILOXANE  | 
			
			 1 ug/g  | 
			
			 0 ug/g  | 
			
			 0 ug/g  | 
			
			 1 ug/g  | 
		
| 
			 HYDROCARBON, OTHERS  | 
			
			 19 ug/g  | 
			
			 15 ug/g  | 
			
			 14 ug/g  | 
			
			 16 ug/g  | 
		
| 
			 TOTAL  | 
			
			 60 ug/g  | 
			
			 55 ug/g  | 
			
			 48 ug/g  | 
			
			 54 ug/g  | 
		
FTIR / SILICONE OIL / HYDROCARBONS
- Below shown was obtain from the analyzed result on one section of the Spiral Coil.
| 
			 
  | 
			
			 Section 1 Sample  | 
			
			 Limits  | 
		
| 
			 SILICONE OIL  | 
			
			 10  | 
			
			 As per customer's specification  | 
		
| 
			 HYDROCARBONS  | 
			
			 160  | 
			
			 As per customer's specification  | 
		
Note: Result for both the silicone oil and hydrocarbons are in nanograms/cm square surface area.
IONIC CONTAMINTAION - The result tested as follows
| 
			 SAMPLE  | 
			
			 Section1 Sample (ug/cm square)  | 
			
			 Section 2 Sample  | 
			
			 Section 3 Sample  | 
			
			 Average  | 
			
			 Limits  | 
		
| 
			 AMMONIUM  | 
			
			 0.015  | 
			
			 0.014  | 
			
			 0.020  | 
			
			 0.016  | 
			
			 As per customer's specification  | 
		
| 
			 BROMIDE  | 
			
			 0.008  | 
			
			 0.008  | 
			
			 0.004  | 
			
			 0.007  | 
		|
| 
			 CALCIUM  | 
			
			 0.019  | 
			
			 0.020  | 
			
			 0.022  | 
			
			 0.020  | 
		|
| 
			 CHLORIDE  | 
			
			 0.008  | 
			
			 0.010  | 
			
			 0.014  | 
			
			 0.010  | 
		|
| 
			 FLUORIDE  | 
			
			 0.032  | 
			
			 0.029  | 
			
			 0.031  | 
			
			 0.030  | 
		|
| 
			 MAGNESIUM  | 
			
			 0.001  | 
			
			 0.001  | 
			
			 0.001  | 
			
			 0.001  | 
		|
| 
			 NITRATE  | 
			
			 0.003  | 
			
			 0.004  | 
			
			 0.004  | 
			
			 0.003  | 
		|
| 
			 NITRITE  | 
			
			 0.000  | 
			
			 0.000  | 
			
			 0.000  | 
			
			 0.000  | 
		|
| 
			 PHOSPHATE  | 
			
			 0.086  | 
			
			 0.069  | 
			
			 0.071  | 
			
			 0.075  | 
		|
| 
			 POTASSIUM  | 
			
			 0.010  | 
			
			 0.012  | 
			
			 0.011  | 
			
			 0.011  | 
		|
| 
			 SODIUM  | 
			
			 0.155  | 
			
			 0.150  | 
			
			 0.147  | 
			
			 0.150  | 
		|
| 
			 SULFATE  | 
			
			 0.000  | 
			
			 0.005  | 
			
			 0.000  | 
			
			 0.001  | 
		|
| 
			 TOTAL SUM OF ANIONS  | 
			
			 0.337  | 
			
			 0.322  | 
			
			 0.325  | 
			
			 0.324  | 
		
ROHS FOR SPIRAL COIL - On analysis, the following result were obtain:
| 
			 Test Parameter  | 
			
			 Digestion / Extraction Method  | 
			
			 Analysis Method  | 
			
			 Result, ppm (w/w)  | 
		
| 
			 Mercury (Hg)  | 
			
			 AC/RoHS/0010 Ver1.1/05 Wet Acid Digestion (Microwave)  | 
			
			 CVAAS  | 
			
			 ND  | 
		
| 
			 Lead (Pb)  | 
			
			 AC/RoHS/0007 Ver1.0/05 Dry Ashing  | 
			
			 ICP-AES  | 
			
			 ND  | 
		
| 
			 Cadmium (Cd)  | 
			
			 AC/RoHS/0007 Ver1.1/05 Wet Acid Digestion (Microwave)  | 
			
			 ICP-AES  | 
			
			 ND  | 
		
| 
			 Hexavalent Chromium (Cr 6+)  | 
			
			 Ac/RoHS/0011 Ver1.0/05 EPA 3060A / 7196A (Modified)  | 
			
			 ND  | 
		|
| 
			 Polybrominated Biphenyls (PBB)  | 
			
			 AC/RoHS/0012 Ver1.1/05 (Microwave)  | 
			
			 GC-MS  | 
			
			 ND  | 
		
| 
			 Plybrominated Diphenyl Ethers (PBDEs)  | 
			
			 AC/RoHS/0012 Ver1.1/05 (Microwave)  | 
			
			 GC-MS  | 
			
			 ND  | 
		
REMARKS
Sample was prepared as in AC/ROHS/0006 Ver1.0/05 and all the methods listed above are reference to the IEC 111/24/CD/Ed.1- Procedure for determination of levels of regulated Substances in Electrotechnical Products.
CVAAS = Cold Vapour Atomic Absorption  Spectrometry
	ICP – AES = Inductively- Coupled Plasma – Atomic Emission Spectrometry
	GC-MS = Gas Chromatography – Mass Spectrometry 
The Method detection limits(MDL) for Lead, Cadmium, Polybrominated Biphenyls and Polybrominated Diphenyl Ethers = 1 ppm each
The Method detection limits(MDL) for Hexavalent Chromium = 2ppm
The Method detection limits(MDL) for Mercury = 0.5ppm
“ND” = Not detected (Less than or equal to 5ppm)