TR4 Direct

TR4 Direct

Danh mục: Safety switches Có sẵn
Để biết thêm thông tin, truy cập trang web chính thức của chúng tôi tại truserv.com.my

Specifications
  • Actuator coding level: Low coding level, High coding level
  • Boundary area indication: No, Yes
  • Certificate: EC-Type-Examination approval, China-RoHS, EU declaration of conformity, UK declaration of conformity, ACMA declaration of conformity, cULus certificate
  • Challenge: No wear, manipulation protection, Door offset, Heavy contamination, Simple diagnostics
  • Coding: universally coded, uniquely coded
  • Connection type: cable, cable with plug M12, 8-pin, cable with plug M12, 5-pin
  • Design: cylindrical, rectangular
  • Emergency stop pushbutton (illuminable): No
  • Enclosure rating: IP69K, IP67
  • Escape release: No
  • Functional principle: RFID
  • Housing diameter: M18
  • Housing material: plastic
  • LED: Yes
  • Length of cable: 3 m, 10 m, 0.2 m
  • Magnetic retaining force: Yes, No
  • Plus/minus button: No
  • Product family: TR4 Direct
  • Product segment: Safety switches
  • Product subsegment: Non-contact safety switches
  • Product type: RFID safety switch
  • Protective collar: No
  • Pushbuttons: No
  • Retaining force: 10 N
  • Safe series connections: with Flexi Loop (with diagnostics), with T-connector (without diagnostics), in control cabinet (with diagnostics)
  • Safety level: PL e, SIL 3
  • Safety task: Safe monitoring of doors and flaps
  • Sensing range: 25 mm, 15 mm
  • Suitable for muting applications (with UE403): No
  • Suitable for reset/override applications (with deTec4): No
  • System part: Sensor with actuator
  • Type of output: Self-monitoring semiconductor outputs (OSSDs)
Mô tả

RFID safety switch for door monitoring with manipulation protection
The TR4 Direct RFID safety switch is used for applications where a high level of manipulation protection is required.
TR4 Direct has monitored semiconductor outputs (OSSD) and can therefore be connected directly to a safety controller. The safety switch is only released if a valid actuator is located within the response range of the TR4 Direct. Two actuation principles are available: For universally coded variants, any universally coded actuator can be located in the response range. For uniquely coded variants, only the uniquely coded actuator that has been taught in with the matching code stored may be located within the response range. Up to 30 safety switches, all with LED status indicators, can be connected in series, thereby making electrical installation and service both straightforward and convenient.

TR4 Direct AT A GLANCE
Benefits

-High level of manipulation protection due to individually coded actuator (depending on the type)
-High level of machine availability due to large door offset tolerances and periphery indicator
-High level of reliability due to resistance to shock and vibration
-Economical solution due to series connection of up to 30 sensors
-Long product service life due to low-wastage and low-maintenance configuration
-Fast diagnosis via LED status indicator
-The devices are easy to clean, making them ideal for use in highly contaminated areas or applications with stringent hygienic requirements
-Flexi Loop: Reliable series connection including diagnostics with minimal wiring work

Features
-Response range of up to 25 mm
-Unique and universally-coded sensors up to enclosure rating IP 69K
-Up to performance level PL e (EN ISO 13849)
-Two OSSD safety outputs
-Reliable series connection of up to 30 sensors possible (depending on the variant)
-LED status indicator
-Periphery indicator and magnetic holding force (optional)
-Flexi-Loop-compatible M12 plug connector (depending on the variant)

Xem thêm chi tiết về Truserv Technologies (M) Sdn Bhd
Truserv Technologies (M) Sdn Bhd
Truserv Technologies (M) Sdn Bhd SICK Sensor Supplier Penang, Safety Devices & Controller Supply Malaysia, Vision Sensor Supplies Bayan Lepas ~ Truserv