Application
Xonic 10G use transit-time, time difference method to measure flow, and use DSP technology for best performance. And, also it use Cross Correlation technology and FFT technology for very clean ultrasonic signal. Xonic 10G can be used for air, natual gas, combustion gas, etc.
Input and Output
- 2 Analog Inputs for Temperature & Pressure
- 2 Analog Outputs for Total & Alarms
- RS232C/485 Modbus
Xonic 10G Performance
- Velocity Range : 0.01~40m/s
- Accuracy : 1.0% single path 0.5% dual path
- Sensitivity : 0.01m/s
Datalogger : 4Mb - Repetability : 0.25%
- Display : Color Graphic LCD 128x64
- Operating Temperature
Flow Computer : -20 ~ +60℃
Transducer : -40 ~+120℃ - Power : DC12~24V
- Enclosure : IP65 - Transducer : IP68 (intrinsically safe)
Explosion Proof Model 10GX
- Explosion Proof Ex d IIB T6
- Cast Aluminum Alloy Case
- Wall Mount Type
- Size : 220(W)x350(H)x170(D)