详情
Circutor CVM-C5 Multifunction Multimeter
Description
The
CVM-C5 is a panel mounted (96 x 96 mm) multimeter that records energy values. Compact and intuitive, with 4-quadrant measurement (Consumption and Generation). The
CVM-C5 is suitable for Low Voltage installations, in both 3 and 4-wire three-phase circuits, two-phase circuits with or without neutral, single-phase circuits or ARON connections.
Display features and interface:
-
Quick display of parameters with a single button
-
Clearly displays the electric parameters of the installation
-
Displays the electricity consumption value according to the cost per kWh
-
kgCO2 consumption/generation indicator or according to the energy source
-
Backlit LCD screen
-
Operating hour indicator for preventive maintenance.
Other features:
-
Modbus/RS-485 communications (optional)
-
Measurement with CIRCUTOR’s MC efficient current transformers or .../5 A, .../1 A or .../333 mV transformers.
-
1 digital output (S0 interface)
-
1 digital input (tariff or energy source selection)
-
Maximum, minimum values and maximum demand.
Applications:
-
Recording and displaying the consumption of energy from two different sources (network/generator set).
-
Generation of an impulse signal associated with the cost, kgCO2 emissions or savings, according to the consumption or generation of energy.
-
Generation of alarms with a transistor output; configurable parameters: Low/High, hysteresis (%), NO/NC, connection/disconnection delay and interlocking.
Technical features
Power Circuit |
Power supply voltage |
85-265 Vac / 50...60 Hz
95-300 Vdc |
Measurement Circuit |
Voltage |
300 Vac p-n / 520 Vac p-p |
Frequency |
45 ... 65 Hz |
Current |
.../5 A or .../1 A
MC: .../250 mA
.../333 mV |
Sampling |
32 samples/cycle |
Accuracy Class |
V, A |
0,5% |
Power / Energy |
1% |
Output |
1 digital output |
S0 interface
Configurable, up to 1,000 impulses per kW·h,
kvar·h, etc.
(24 Vdc max., 50 mA, 5 imp/s,
Configurable Max. Ton/Toff) |
Communications |
Protocol |
RS-485 Modbus/RTU (depending on model) |
Speed |
9600, 19200, 38400 |
Bit, parity, stop |
8, n, 1 |
Build Features |
Enclosure |
VO self-extinguishing plastic |
IP protection degree |
Front panel: IP 51
Rear: IP 21 |
Dimensions |
96,7 x 96,7 x 62,60 mm |
Environmental Conditions |
Working temperature |
-5...+45 ºC |
Storage temperature |
-10...+50 ºC |
Relative humidity |
5 ... 95% |
Maximum altitude |
2000 m |
Safety |
Class III according to EN 61010
Double-insulated electric shock protection, Class II |
Standards |
IEC 664, VDE 0110, UL 94, IEC 801, IEC 348, IEC 571-1, EN 61000-6-3, EN 61000-6-1, EN 61010-1, CE, UL certified |
References
Current input |
Inputs |
Outputs |
Communication |
Type |
Code |
.../5 A, .../1 A |
1 |
1 |
- |
CVM-C5-IC |
M55853 |
.../250 mA |
1 |
1 |
- |
CVM-C5-MC-IC |
M55873 |
.../333 mV |
1 |
1 |
- |
CMV-C5-mV-IC |
M558730000V00 |
.../5 A, .../1 A |
- |
1 |
RS-485 |
CVM-C5-ITF-485-C |
M55884 |
.../5 A, .../1 A |
1 |
- |
RS-485 |
CVM-C5-ITF-485-I |
M55885 |
.../250 mA |
- |
1 |
RS-485 |
CVM-C5-MC-485-C |
M55894 |
.../250 mA |
1 |
- |
RS-485 |
CVM-C5-MC-485-I |
M55895 |
.../333 mV |
- |
1 |
RS-485 |
CVM-C5-mV-485-C |
M558940000V00 |
.../333 mV |
1 |
- |
RS-485 |
CVM-C5-mV-485-I |
M558950000V00 |
Dimensions
Connections
Three-phase + neutral connection with or without voltage transformers
Single-phase connection with or without voltage transformers
Panel Mounted / Energy Values / Circutor / Electric Parameters / Low Voltage / ARON Connection / Backlit LCD SCREEN / Multifunctional multimeter. CVM-C5 from Saturn Pyro is the best available in Malaysia. High performance and cost effective Power Energy Meter which is suitable for Low Voltage installations, in both 3 and 4-wire three-phase circuits, two-phase circuits with or without neutral, single-phase circuits or ARON connections.. Available in Penang, KL, Selangor, Johor, Sabah, Sarawak & anywhere in Malaysia & Singapore.
Saturn Pyro provides reliable engineering services such Electrical Safety Survey, Power System Studies (Short Circuit, Load Flow & Protection Discrimination on ETAP), Arc Flash Assessment & Labeling, Design Of Earthing & Lightning Protection, Measurement Of Touch & Step potentials, Power Quality Management, Energy Audit and Data Center Performance Assessment. We also provides Electrical Safety Survey such as Inspection of an electrical installation, Identification of risk (electrical hazards), Review of documentation, operations & maintenance procedures, contingency planning, Generation of report in details of risk potentials and plan for mitigation, Closing report post implementationas. Available in Pulau Pinang, Johor, Kuala Lumpur (KL), Selangor and anywhere in Malaysia / Singapore / Bangalore / India / Mumbai.
更多 Saturn Pyro Sdn Bhd 相关资料