Yokogawa Touch Screen GP10GP20
SMARTDAC+TM GP10/GP20 is a paperless recorder that provides intuitive, human-centric design, web-enabled functionality, and scalable architecture.
Schedule management for periodically executing calibration correction configuration and the like. Compliant with heat treatment standard CQI-9 adopted by major companies in the automotive industry.
> Heat treatment special site
The advanced security function provides safety to use. With the expansion of the advanced security function option (/AS), it corresponds to US FDA 21 CFR Part 11, EU-GMP Annex 11, and data integrity in accordance with ALCOA +.
> What is ''ALCOA +''?
Download technical data:
Regarding analog measurement, we have summarized the frequently asked questions in [Basic], [Applied], and [Noise Countermeasures]. > Download
OpreX is the comprehensive brand for Yokogawa’s industrial automation (IA) and control business and stands for excellence in the related technology and solutions. It consists of categories and families under each category. This product belongs to the OpreX Data Acquisition family that is aligned under the OpreX Measurement category.
-* Creating predictive detection models and profile waveforms requires the Equipment/Quality Predictive Detection tool (sold separately).
By easily creating predictive detection models from past recorded OK/NG (Not Good) data and loading it into GX/GP, you can detect prediction of abnormalities in manufacturing equipment and product quality degradation at an early stage. And because health scores which show the degree of normal and abnormal data consider correlations among multiple data to make determinations, they can capture prediction of abnormalities that are difficult for humans to detect.
Health monitor function empowers you to:
By creating a profile waveform from past recorded data and loading it into GX/GP, this waveform can be used as a threshold for process values. Profile waveforms are useful in applications where process values change over time. Also, you can see the deviation from the reference waveform on the screen.
Profile function empowers you to:
Please refer to the application notes for the proven effects and use cases of predictive detection.
By creating predictive detection model and profile waveform, Cloud or Offline Equipment/Quality Predictive Detection tool (paid separately) is required. To use cloud version, you need to apply from the following site to create an account.
*There are some functional restrictions during the free trial period.
> Click here to apply for the cloud version
> Click here to download the offline version
*Search ''OE10'' on the member's site.
Note: Cloud version is available only for US, Canada, EU and UK.
AI comes standard on the GX/GP. No complicated settings. Simply register channels, and you're ready to draw future measured data on those channels.
Use acquired data to predict future data, and display predicted future waveforms along with real time data on the trend monitor. Predicted future waveforms help you identify and deal with likely problems as soon as possible.
You can set future alarms based on future data predicted by the future pen. You can check future alarm information in the Future Alarm Summary screen. Also, when a future alarm occurs, notification can be sent by external (digital) output or email. Because the future alarm information also includes the predicted alarm time, you can also identify the urgency.
* Effective for relatively slowly fluctuating data. Not suitable for rapidly fluctuating data.
* Certain restrictions apply with the future pen function. See the general specifications for details.
> Please refer to this video. (open in new window)
Seamless display of historical trends—flick or drag the trend display to scroll through the data, even during measurement.
From a calendar, jump to waveforms of a specific date. From the alarm summary, jump to the waveform active during the alarm.
Immediately clear areas of concern with a hand-written message. ou can draw or hand-write on the waveform area using a stylus or the tip of your finger.
Save trend waveforms of interest or screens displayed during alarms as image (PNG) files, and print them out at the same time.
Move the scale to display the value corresponding to that position as a numeric value. Instantly check maximum/minimum measured values.
[Patent technology]
All historical trends display
Long-duration trends can be fitted to a single screen for easy viewing.
All historical trends display
The time axis and engineering axis can expanded and compressed using a simple pinch together or apart function
Pinch apart / Pinch together
Log scale display (/LG option)
You can select from 9 layouts, and save up to 20 configurations. (Multi panel available on the GX20 only)
Various pre-configured control screens and display are available.
You can arrange display objects such as trend, numeric, and bar graphs any way you like to create monitor displays that are customized to the environment. Start/stop pumps and perform other operations.
DAQStudio is software for creating custom displays. You can load screens you created onto the GP via Ethernet or external memory media (SD/USB) and display them.
Inputs and outputs are modular for easy expandability. The GP multichannel paperless recorder main unit alone provides up to 100 channels (GP20) of measurement.
Select from a wide variety of input/output modules.
Model | Name | Measurement/Application | Channels |
---|---|---|---|
GX90XA-10-U2 | Analog input module | DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (solid state relay scanner type) | 10 |
GX90XA-10-L1 | DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Low withstand voltage solid state relay scanner type) | 10 | |
GX90XA-10-T1 | DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (electromagnetic relay scanner type) | 10 | |
GX90XA-10-C1 | DC current (mA) (solid state relay scanner type) | 10 | |
GX90XA-10-V1 | DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Solid state relay scanner type) | 10 | |
GX90XA-04-H0 | DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (individual A/D type) | 4 | |
GX90XA-06-R1 | 4-wire RTD, 4-wire resistance (solid state relay scanner type) | 6 | |
GX90YA | Analog output module | Current output | 4 |
GX90XD | Digital input module | Remote control input or operation recording | 16 |
GX90YD | Digital output module | Alarm output | 6 |
GX90WD | Digital input/output module | Remote control input or operation recording/alarm output | DI:8/DO:6 |
GX90XP | Pulse input module | Pulse signal data acquisition, integral count | 10 |
GX90UT | PID control module | PID control (2 loop) |
AI:2/AO:2 DI:8/DO:8 |
* For details on each module, refer to the general specifications.
You can also select modules using the convenient selection tool Product Finder .
Supports up to 450 channels of measurement. Note that if MATH and communication channels are included, the GP20 large memory type can record on up to 1000 channels. The GP main unit and expandable I/O can both use the same input/output modules
You connect directly with a LAN cable without connecting through a hub or repeater. * You can also connect subunits of the GM Data Acquisition System.
Model | Type | Max.channels | Number of channels by configuration | |
---|---|---|---|---|
GP10 | Standard | 100ch | Main unit only | 0-30 |
Main + expandable I/O | 0-100 | |||
GP20 | Standard | 100ch | Main unit only | 0-100 |
Main + expandable I/O | 0-100 | |||
Large memory | 450ch | Main unit only | 0-100 | |
Main + expandable I/O | 0-450 |
The number of channels is for analog input only.
When the recorder is installed offsite (away from the DUT), you can place the expandable I/O at the site and monitor data without the need for long-distance wiring of thermocouples and other sensors.
PID and program control
Through a Web browser you can monitor the GP in real time and change settings. You can easily build a seamless, low-cost remote monitoring system with no additional software.
Real time monitoring screen
You can view monitor screens in real time that are identical to the trends, digital, and other displays on the GP main unit.
*Notice on Java Plug-in running in Web browser for SMARTDAC+ series
Enter settings online with a web browser
The setting screen lets you copy AI channel settings and other information to Excel for editing. You can reimport the data into the setting screen after editing.
Data files saved on the GX/GP can be viewed and printed. You can perform statistical computation over an area and export to ASCII, Excel, or other formats.
Save settings or transfer them to the GX/GP.
Schedule management for periodically executing calibration correction configuration and the like. The correction factor can be set separately for unit and sensor dependency. For AMS2750, we offer TUS software* that can easily create TUS (temperature distribution test) reports.*.
* For information on TUS software, contact your Yokogawa representative.
Recorder pre-defined channel groups to separate data files with independent start and stop control. Up to 12 independent batches can be created.
Combine and integrate complex legacy control panel into a simple and flexible data acquisition station.
Yokogawa's proprietary A/D converter allows the high speed module to measure data points as fast 1ms.
*With 1ch per module. At 2 ms, 2 ch per module, and at 5 ms or more, all 4 ch per module.
Model | Scan interval | ||
---|---|---|---|
1ms | 2ms | 10ms | |
GP10 | 1ch | 5ch | 10ch |
GP20-1 | 1ch | 5ch | 10ch |
GP20-2 | 5ch | 25ch | 40ch |
Users have the ability to choose two different scan intervals on a single GX/GP system. This allows users the flexibility to measure various types of inputs with two different scan intervals in a single system. For example, this provides for efficient, simultaneous measurement of signals with slow fluctuations such as temperature, and fast-changing signals such as pressure and vibration. Modules can be assigned to measurement groups.
Supports various kinds of math computation, including basic math and functions (square root, logarithms, trigonometry). Write formulas using variables for measured or computed data and save or display the results—this saves time and effort on post-processing. Create hourly, daily, monthly, and other reports with the Report function.
Ability to assign actions tied to specific events during the operation of the data acquisition station.
When the form template created arbitrarily is read into the internal memory of GP, a report in Excel or PDF format is automatically created. You can also output to a printer via LAN connection.
Provides a variety of convenient networking functions
GP supports Modbus TCP/IP client and server modes for Ethernet communications and Modbus RTU master and slave modes for optional serial communications.
Using the Modbus/TCP and Modbus/RTU functions, you can display and save data from the server and slave devices on the GP.*
* Requires the communication channel (/MC option ).
Using the Modbus/TCP and Modbus/RTU functions, you can acquire GP data from upstream devices.
(Connect up to 16 Modbus/TCP servers, or up to 32 for the GP20-2.)
(Up to 31 Modbus/RTU slaves can be connected.)
Using the EtherNet/IP server function, you can access the GX from a PLC or other device to read measurement/computation channels and write to communication input channels (GX10: up to 500ch, GX20-1: up to 300ch, GX20-2: up to 500ch). Communication channel function (/ MC option) is required.
In addition, the following operations required for batch processes can be performed through the PLC using Explicit messages.
Note: Explicit message operation in OMRON PLC has not been confirmed.
Protocol function that enables connection from a GP to Mitsubishi Electric PLCs without sequencer programs. You can run the GP as an SLMP client, enabling writing of GP measured data to the PLC and writing of PLC data to communication channels.*
By using the GX90NW network module, you can connect the GX/GP as a secondary I/O device via PROFINET. You can access the GX/GP from the PLC or other I/O controller, read measurement/math channels, and write to communication channels*. You can easily perform necessary operations for batch processes from the PLC.
* Communication channel function (/MC option) is required.
Highly precise measured data from power measuring instruments (WT series power analyzers) can be acquired without loss of fidelity on the GP, and recorded and displayed alongside the GX's own measured data. This is ideal for performance evaluation testing because you can record instrument power consumption, temperature, and other phenomena simultaneously.
Data acquired by the GP can be accessed through Ethernet communication from a host system (OPCUA client). Writing from an upstream system to a GP communication channel requires the communication channel function (/MC option).
The GX supports DARWIN communication commands. Use your current DARWIN communication programs as-is on the GP.*
* See your dealer or nearest Yokogawa representative for details.
CENTUM/STARDOM communciation package
The FTP client/server functions allow you to easily share and manage data from a centralized file server.
Send alarm occurrence information, scheduled instantaneous values, report data, etc. by e-mail.
Using Dynamic Host Configuration Protocol (DHCP), the GP can automatically acquire the settings it needs (IP address) for network communications from a DHCP server. This makes it easier than ever to install the unit on a plant network.
GP uses SNTP protocol in client mode to acquire time information from a network time-server. This function allows any number of GP units within a facility to have precisely synchronized time; all units will record data with coordinated date and time stamp information. In addition, GP can function as a server, providing time data to other SNTP client units on the network.
Measured and calculated data is continuously saved to secure, internal non-volatile memory. At manual or scheduled intervals, the files in memory are copied to the removable media. In addition, the files can be copied and archived to an FTP server.
Because of the inherent reliability and security of non-volatile memory, the possibility of losing data under any operating condition or power failure event is extremely small.
For increased security, measured data can be saved in binary format. This format is very difficult to decipher or modify in traditional text editors or other programs. To enable easy and direct opening of the data in text editors or spreadsheet programs, choose text format. This allows you to work with your measurement data without dedicated software.
Safely sends and receives customer data.
SSL: An encryption protocol for data sent over TCP/IP networks.
The front panel door can be locked to prevent mishandling of the power switch or external media.
A proprietary A/D converter delivers high speed, high precision data acquisition. (High-speed AI, PID Control module)
GX supports various standards such as CSA, UL, CE/EMC Directive/CE/Constant Voltage Directive, European RoHS Directive, WEEE Directive, RCM, KC Mark (Korea).
SMARTDAC+ GX /GP/GM advanced security function option (/AS) provides safe and traceable data management in applications such as pharmaceutical manufacturing, biotechnology, health management, and medical institutions.
The advanced security function supports the strict requirements of US FDA 21 CFR Part 11, EU-GMP Annex 11 and other associated guidelines for data management.
It also supports data integrity in accordance with ALCOA+ (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available) mentioned in PIC/S, WHO, MHRA and FDA guidance documents.
What is ''ALCOA +''?
It refers to A: attribution, L: legibility, C: simultaneity, O: originality, A: accuracy, C: completeness, C: consistency, E: Persistence, and A: Availability. ALCOA + is a requirement for data integrity guidelines of PIC / S (Pharmaceutical Testing Contract and Pharmaceutical Testing Joint Scheme), WHO (World Health Organization), MHRA (Pharmaceuticals and Drug Regulatory Authority: UK), and FDA (Food and Drug Administration).
Measured data, settings, and operation logs are saved to a single encoded binary file. Encoded data in binary format offers a high level of security because it cannot be opened in most text editors.
If the data files are damaged or tampered with, SMARTDAC+ Standard Universal Viewer software will identify the nonconformity and notify the user accordingly.
SMARTDAC+ can automatically transfer data to an FTP server. FTPS, which encrypts data transferred via FTP using SSL, is also supported, allowing data files to be transferred safely.
Measurement data can be displayed and confirmed on the GX/GP (only the data in the internal memory) or the SMARTDAC+ Standard Universal Viewer software, and an electronic signature can be applied to that data. Three levels of signature are available: operator, supervisor and quality control. The signature along with information such as pass/fail and comments can be saved to the data for review and audit.
*Electronic signature to the GM is possible only from the SMARTDAC+ Standard Software. Electronic signature cannot be applied through GM's web server.
Data integrity requires that the right users have access to the right information.
SMARTDAC+ can create users with various access privileges.
The SMARTDAC+ operation log is saved to a file along with measurement data.
When settings are changed, it is possible to record the reason for the change along with the setting change operation. In addition, checking the details of setting changes from ''setting difference operation history'' makes greatly reduces the data checking work during audits.
SMARTDAC+ Standard Software is possible to display measurement data, display the operation log, and configure the GX/GP/GM. It is also possible to sign in data using the SMARTDAC+ Standard Universal Viewer.
The Universal Viewer software can display data files in various forms such as waveforms and numeric values. It can display and print not only measurement data but also alarm and message lists and operation logs. With the operation log, a comparison of the settings before the change and those after the change can be displayed, allowing you to check the changes in detail.
It is also possible to sign the data by entering the user name, user ID and password after confirming the measurement data. If the data has already been signed, you can sign at a different level after confirming the signature state on the screen.
Hardware Configurator software allows for offline system configuration which can be imported via SD memory or external storage media as well as Ethernet communication. System settings can be printed in a table format to support GX /GP/GM system validation (IQ/OP/PQ).
In addition, a pair of selected setup data files can be compared, and their differences can be displayed and printed in table format.
Validation documentation (sold separately) is a validation protocol template that simplifies GX/GP/GM and SMARTDAC+ Standard system validation. The document is provided on the Yokogawa website as an MS Word file for easy editing.*
*The validation and document verification are the customer’s responsibility.