PowerMAX500 4P Cat.6 U/UTP 23AWG PVC Cable - Blue

PowerMAX500 4P Cat.6 U/UTP 23AWG PVC Cable - Blue

分类: DINTEK 当前有货
可在官方网站购买
欲了解更多详情,请游览我们的官方网站 thcomm.com.my

详情

PowerMAX500 4P Cat.6 U/UTP 23AWG PVC Cable - Blue

Product Code: 1101-04045

DINTEK PowerMAX500TM unshielded Cat.6 / Class E U/UTP PVC cable
is guaranteed to exceed Cat.6 specifications as set down in ANSI/TIA and ISO/IEC standards.
Our PowerMAX500
TM solution comprises unshielded Cat.6
component compliant patch panels, keystones, and patch cords.


When combined with DINTEK’s unshielded Cat.6 / Class E U/UTP PVC cable,
an end-to-end channel exists that maximizes data throughput and provides headroom
for future technologies operating to, and beyond 1 Gigabit Ethernet.


Features & Applications
Standards Conformance
Independent Verified Certifications
Features

Performance Statistics

Frequency Mhz Insertion Loss dB/100mtrs NEXT (dB) Return Loss (dB)
1 2 74.3 20
4 3.8 65.3 23
10 6 59.3 25
16 7.6 56.3 25
20 8.5 54.8 25
31.25 10.7 51.9 23.6
62.5 15.4 47.4 21.5
100 19.8 42.4 20.1
200 29 39.8 18
250 32.8 38.3 17.3

Meets and exceeds values above based on 100 meters (328 ft.) at 20°C as per
ANSI/TIA-568-D.2 for Cat.6 / ISO/IEC 11801 Class E / EN 50173.


DINTEK PowerMAX500TM Cat.6 / Class E cables have additionally been tested up to 500Mhz
and have shown performance results that allow for successful transmission of 10 Gigabit Ethernet up to 70Mtrs.


Ordering Information
Product Number Product Name Jacket Rating Color Length Qty Qty / Pallet
1101-04045 PowerMAX500 4P Cat.6 U/UTP 23AWG PVC Cable CM Blue 305Mtr Box 24 or 36

Technical Specifications
Construction
Conductor  
Material Pure Annealed Copper
Wire Size 23AWG
Strand Type Solid Core
No. Of Pairs 4P

Insulation  
Material Polyethylene
Thickness 0.21mm ± 0.01mm
Diameter 0.98mm ± 0.05mm
Colors Blue/White | Orange/White | Green/White | Brown/White
Pair Foil Wrap None


Jacket  
Material PVC
Thickness 0.5 mm ± 0.05mm
Diameter 5.70mm ± 0.3mm
Color Blue
Jacket Rating CM
Foil Shield None
Braided Shield None


Physical Ranges
Jacket  
Cold Bend Test -20 ± 2°C x 4hrs no crack
Min. Bending Radius Min. 4 x Cable Diameter
Max. Pulling Tension 110N
Installation Temperature 0°C to +50°C
Operating Temperature -20°C to +60°C

Electrical
Conductor Resistance Max. 9.38 Ω/100m at 20℃
DC Resistance Unbalance Max. 2% at 20°C
Pair-to-Ground Capacitance Unbalance Max. 1600 pF/km at 1 kHz
Dielectric Strength of Insulation DC 1 kV for 1 min
Insulation Resistance Test (500V) Min. 5000 MΩ/Km at 20°C
Mutual Capacitance Max. 5600 pF/100m at 1 kHz
Impedance 1~250MHz 100Ω ± 15%
Nominal Velocity Of Propagation 67%

 
 