Reverse Fan Cleaning Function:
During cleaning, the fan operates in reverse to prevent foreign objects from blowing onto the product.
Precise Ion Balance:
Features an automatic ion balance system that maintains ion balance within 0 ± 10V, ensuring high precision.
Customizable Length:
Ion fan lengths can be selected based on the size of the workbench and product, providing flexibility for different setups.
Automatic Needle Cleaning:
Equipped with an automatic discharge needle cleaning function, which reduces the need for frequent manual maintenance.
Advanced Locking and Monitoring:
Includes a machine locking function, wireless monitoring, and supports two modes: LORA+NB IoT for enhanced control and security.
Adjustable Cleaning Timer:
Based on the workshop environment, the cleaning and discharge needle time can be adjusted from 0 to 999 hours using an LED digital display, offering convenience and customization.
Product model | KF-150AR |
Input power supply voltage | DC24V |
Decay normal operation indicator light | If decay operation is normal,the green indicator light is on |
Decay abnormal indicator light | If decay operation is abnormal,the red indicator light is on |
Decay time | about 1.5s (300mm) |
Ion balance | Automatic ion balance system 0±10V |
Air volume | 2.97-4.07m³/min(constant air flow) |
Ozone concentration | Below 0.03ppm(distance 150mm) |
Applied environmental temperature | 0~40℃(no condensation) |
Applied environmental humidity | 30-70% RH (no water drop condensation) |
Overall size /mm | 1400*82*150(exclouding stents) |
Weight | 8.02Kg (exclouding stents) |
Anti-static test condition
|
||||
Operating voltage : DC24V, Test voltage : ±1000V-±100V, Ambient temperature : 23℃±2℃ | ||||
Distance | 300mm | 600mm | 900mm | |
Decay Time | Positive | 1.0s/1.5s | 2.0s/3.0s | 3.5s/4.5s |
Negative | ||||
Ion Balance | Positive | 0±10v | 0±15v | 0±20v |
Positive |