Reverse Fan Cleaning:
The fan reverses during cleaning to prevent foreign particles from being blown onto the product, ensuring a clean environment.
Precise Ion Balance:
The automatic ion balance system maintains ion levels within 0 ± 10V, ensuring consistent static elimination.
Customizable Fan Sizes:
Ion fans are available in different lengths to match the size of the workbench and product, offering flexibility in various applications.
Automatic Discharge Needle Cleaning:
This function reduces the need for frequent manual cleaning, saving time and effort.
Locking and Wireless Monitoring:
The equipment includes a complete locking function and wireless monitoring, supporting both LORA and NB IoT modes for enhanced operational control.
Adjustable Cleaning Timer:
Cleaning and discharge needle intervals can be set from 0 to 999 hours, with an LED display for easy monitoring based on the workshop environment.
Product model | KF-80AR |
Input power supply voltage | DC24V |
Decay normal operation indicator light | If decay operation is normal,the green indicator light is on |
Decay abnormal indicator light | If decay operation is abnormal,the red indicator light is on |
Decay time | about 1.5s(300mm ) |
Ion balance | Automatic ion balance system 0±10V |
Air volume | 2.97-4.07m³/min(constant air flow) |
Ozone concentration | Below 0.03ppm(distance 150mm) |
Applied environmental temperature | 0~40℃(no condensation) |
Applied environmental humidity | 30-70% RH (no water drop condensation) |
Overall size /mm | 800*82*150(exclouding stents) |
Weight | 4.74Kg (exclouding stents) |
Anti-static test condition | ||||
Operating voltage:DC24V | Test voltage:±1000V-±100V | Ambient temperature:23℃±2℃ | ||
Distance | 300mm | 600mm | 900mm | |
Decay Time | Positive | 1.0s/1.5s | 2.0s/3.0s | 3.5s/4.5s |
Negative | ||||
Ion Balance | Positive | 0±10v | 0±15v | 0±20v |
Positive |